STBART0200K

standard analog input kit, Modicon STB, 2I, 15 bits with sign

AVAILABLE

GET A QUOTE NOW

This product is part of the Modicon STB range, an offer of modular distributed I/O. This standard analogue input kit is an accessory kit of Programmable Logic Controllers (PLC) and Programmable Automation Controllers (PAC). It has 2 analogue inputs with 15bit plus sign resolution. This product is compatible with most major fieldbus networks. It is an analogue input kit with a rated supply voltage of 24V DC and a current consumption of 30mA at 5V DC for logic bus. It is an IP20 rated product. It is suitable for packaging, bottling, assembly, distribution, textile, printing and semiconductor machines applications. This product is certified by FM Class 1 Division 2, ATEX category 3G, CE, UL, CSA and C-Tick. This kit is suitable for use with mounting base STBXBA1000 and power distribution module STBPDT3100/3105. The kit includes STBART0200 module, STBXTS1100, 6-terminal screw type connector, STBXBA1000 base and STBXTS2100, 6-terminal spring clamp connector. The Modicon STB distributed I/O solution is an open, modular input/output system that makes it possible to design automation islands managed by a master controller via a bus or communication network.
Read more arrow Read less arrow
Specification Value
Insulation Between Channels And Logic Bus 1500 V for 1 minute
Cold Swapping yes
Maximum Supply Current For Sensors 100 mA per input channels
Input Impedance 10 MOhm +/- 80 mV
Status Led 1 LED (Green) module status (RDY) || 1 LED (Red) module error (ERR)
Hot Swapping Fallback yes for standard NIMs
Supply power distribution module
Data Format EN 61131-2 || IEC 61131-2
Current Consumption 30 mA 5 V DC logic bus
Marking CE
Fallback Status state 0 basic NIMs || user configurable standard NIMs
Conversion Time 150 ms voltage 60 Hz || 170 ms voltage 50 Hz || 180 ms temperature probe 60 Hz 2 or 4 wires || 200 ms temperature probe 50 Hz 2 or 4 wires || 210 ms thermocouple with internal cold-junction compensation 60 Hz || 230 ms thermocouple with internal cold-junction compensation 50 Hz || 300 ms temperature probe 60 Hz 3 wires || 340 ms temperature probe 50 Hz 3 wires || 360 ms thermocouple with external cold-junction compensation 60 Hz || 400 ms thermocouple with external cold-junction compensation 50 Hz
Addressing Requirement 1 word for cold-junction compensation || 2 input words
Absolute Accuracy Error +/- 0.1 % of full scale 25 °C internal || +/- 0.15 % of full scale 25 °C external
Maximum Wiring Resistance 20 Ohm Cu 10 IEC/US/JIS 2 or 3 wires || 20 Ohm Ni 100 IEC/US/JIS 2 or 3 wires || 20 Ohm Pt 100 IEC/US/JIS 2 or 3 wires || 200 Ohm Ni 1000 IEC/US/JIS 2 or 3 wires || 200 Ohm Pt 1000 IEC/US/JIS 2 or 3 wires || 50 Ohm Cu 10 IEC/US/JIS 4 wires || 50 Ohm Ni 100 IEC/US/JIS 4 wires || 50 Ohm Pt 100 IEC/US/JIS 4 wires || 500 Ohm Ni 1000 IEC/US/JIS 4 wires || 500 Ohm Pt 1000 IEC/US/JIS 4 wires
Absolute Maximum Input +/- 7.5 V DC
Protection Type short-circuit protection
Overvoltage Category II
Product Compatibility mounting base STBXBA1000 || power distribution module STBPDT3100/3105
[Us] Rated Supply Voltage 24 V DC
Measurement Accuracy +/- 1 °C Ni 100 25 °C external || +/- 1 °C Ni 100 25 °C internal || +/- 1 °C Ni 1000 25 °C external || +/- 1 °C Ni 1000 25 °C internal || +/- 1 °C Pt 100 25 °C internal || +/- 1 °C Pt 1000 25 °C internal || +/- 1.75 °C thermocouple B with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple E with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple J with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple K with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple R with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple S with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple T with external cold-junction compensation 25 °C || +/- 2 °C Pt 100 25 °C external || +/- 2 °C Pt 1000 25 °C external || +/- 2.85 °C thermocouple B with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple E with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple J with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple K with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple R with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple S with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple T with external cold-junction compensation 60 °C || +/- 3.6 °C thermocouple R with internal cold-junction compensation 25 °C || +/- 4 °C Cu 10 25 °C external || +/- 4 °C Cu 10 25 °C internal || +/- 4 °C thermocouple K with internal cold-junction compensation 25 °C || +/- 4.1 °C thermocouple S with internal cold-junction compensation 25 °C || +/- 4.2 °C thermocouple R with internal cold-junction compensation 60 °C || +/- 4.4 °C thermocouple T with internal cold-junction compensation 25 °C || +/- 4.6 °C thermocouple B with internal cold-junction compensation 25 °C || +/- 4.6 °C thermocouple E with internal cold-junction compensation 25 °C || +/- 5 °C thermocouple S with internal cold-junction compensation 60 °C || +/- 5.1 °C thermocouple J with internal cold-junction compensation 25 °C || +/- 5.5 °C thermocouple K with internal cold-junction compensation 60 °C || +/- 6.4 °C thermocouple T with internal cold-junction compensation 60 °C || +/- 6.8 °C thermocouple B with internal cold-junction compensation 60 °C || +/- 6.8 °C thermocouple E with internal cold-junction compensation 60 °C || +/- 7 °C thermocouple J with internal cold-junction compensation 60 °C
Measurement Resolution 0.01 mV voltage || 0.1 °C or 0.1 °F temperature probe || 0.1 °C or 0.1 °F thermocouple
Range Of Product Modicon STB distributed I/O solution
Type Of Filter single low pass input filter 25 Hz
Product Or Component Type standard analog input kit
Analogue Input Number 2
Analogue Input Resolution 15 bits + sign
Kit Composition STBART0200 module || STBXTS1100, 6-terminal screw type connector || STBXBA1000 base || STBXTS2100, 6-terminal spring clamp connector
Analogue Input Type voltage +/- 80 mV || temperature probe -100...+260 °C Cu 10 2, 3 or 4 wires IEC || temperature probe -100...+450 °C Pt 100 2, 3 or 4 wires US/JIS || temperature probe -100...+450 °C Pt 1000 2, 3 or 4 wires US/JIS || temperature probe -200...+850 °C Pt 100 2, 3 or 4 wires IEC || temperature probe -200...+850 °C Pt 1000 2, 3 or 4 wires IEC || temperature probe -60...+180 °C Ni 100 2, 3 or 4 wires IEC || temperature probe -60...+180 °C Ni 1000 2, 3 or 4 wires IEC || thermocouple +130...+1820 °C thermocouple B || thermocouple -200...+760 °C thermocouple J || thermocouple -270...+1000 °C thermocouple E || thermocouple -270...+1370 °C thermocouple K || thermocouple -270...+400 °C thermocouple T || thermocouple -50...+1665 °C thermocouple R || thermocouple -50...+1665 °C thermocouple S
Read more arrow Read less arrow
*New items come with up to 24 month Obso Warranty
Our previously used items and repair options come with 12 months Obso Warranty.


"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
*Same & Next Day Delivery & Collection is available for stock from our UK and NL branches. Next-day delivery collection and 2 day delivery is available for stock sourced from our partners. In 90% of cases, we can deliver faster than the manufacturer’s ETA where required.

Standard options for delivery are also available where required.


"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
We are ISO 9001 accredited so you have peace of mind with your purchase.

What our customers say about us

Trustpilot

1

Step 1

    Part added for enquiry

    2

    Step 2

    Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.

    3

    Step 3

    We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.

    4

    Step 4

    Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.