standard analog input kit, Modicon STB, 2I, 15 bits with sign
Dostępny
Uzyskaj wycenę już teraz
| Specification | Value |
|---|---|
| Insulation Between Channels And Logic Bus | 1500 V for 1 minute |
| Cold Swapping | yes |
| Maximum Supply Current For Sensors | 100 mA per input channels |
| Input Impedance | 10 MOhm +/- 80 mV |
| Status Led | 1 LED (Green) module status (RDY) || 1 LED (Red) module error (ERR) |
| Hot Swapping Fallback | yes for standard NIMs |
| Supply | power distribution module |
| Data Format | EN 61131-2 || IEC 61131-2 |
| Current Consumption | 30 mA 5 V DC logic bus |
| Marking | CE |
| Fallback Status | state 0 basic NIMs || user configurable standard NIMs |
| Conversion Time | 150 ms voltage 60 Hz || 170 ms voltage 50 Hz || 180 ms temperature probe 60 Hz 2 or 4 wires || 200 ms temperature probe 50 Hz 2 or 4 wires || 210 ms thermocouple with internal cold-junction compensation 60 Hz || 230 ms thermocouple with internal cold-junction compensation 50 Hz || 300 ms temperature probe 60 Hz 3 wires || 340 ms temperature probe 50 Hz 3 wires || 360 ms thermocouple with external cold-junction compensation 60 Hz || 400 ms thermocouple with external cold-junction compensation 50 Hz |
| Addressing Requirement | 1 word for cold-junction compensation || 2 input words |
| Absolute Accuracy Error | +/- 0.1 % of full scale 25 °C internal || +/- 0.15 % of full scale 25 °C external |
| Maximum Wiring Resistance | 20 Ohm Cu 10 IEC/US/JIS 2 or 3 wires || 20 Ohm Ni 100 IEC/US/JIS 2 or 3 wires || 20 Ohm Pt 100 IEC/US/JIS 2 or 3 wires || 200 Ohm Ni 1000 IEC/US/JIS 2 or 3 wires || 200 Ohm Pt 1000 IEC/US/JIS 2 or 3 wires || 50 Ohm Cu 10 IEC/US/JIS 4 wires || 50 Ohm Ni 100 IEC/US/JIS 4 wires || 50 Ohm Pt 100 IEC/US/JIS 4 wires || 500 Ohm Ni 1000 IEC/US/JIS 4 wires || 500 Ohm Pt 1000 IEC/US/JIS 4 wires |
| Absolute Maximum Input | +/- 7.5 V DC |
| Protection Type | short-circuit protection |
| Overvoltage Category | II |
| Product Compatibility | mounting base STBXBA1000 || power distribution module STBPDT3100/3105 |
| [Us] Rated Supply Voltage | 24 V DC |
| Measurement Accuracy | +/- 1 °C Ni 100 25 °C external || +/- 1 °C Ni 100 25 °C internal || +/- 1 °C Ni 1000 25 °C external || +/- 1 °C Ni 1000 25 °C internal || +/- 1 °C Pt 100 25 °C internal || +/- 1 °C Pt 1000 25 °C internal || +/- 1.75 °C thermocouple B with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple E with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple J with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple K with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple R with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple S with external cold-junction compensation 25 °C || +/- 1.75 °C thermocouple T with external cold-junction compensation 25 °C || +/- 2 °C Pt 100 25 °C external || +/- 2 °C Pt 1000 25 °C external || +/- 2.85 °C thermocouple B with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple E with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple J with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple K with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple R with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple S with external cold-junction compensation 60 °C || +/- 2.85 °C thermocouple T with external cold-junction compensation 60 °C || +/- 3.6 °C thermocouple R with internal cold-junction compensation 25 °C || +/- 4 °C Cu 10 25 °C external || +/- 4 °C Cu 10 25 °C internal || +/- 4 °C thermocouple K with internal cold-junction compensation 25 °C || +/- 4.1 °C thermocouple S with internal cold-junction compensation 25 °C || +/- 4.2 °C thermocouple R with internal cold-junction compensation 60 °C || +/- 4.4 °C thermocouple T with internal cold-junction compensation 25 °C || +/- 4.6 °C thermocouple B with internal cold-junction compensation 25 °C || +/- 4.6 °C thermocouple E with internal cold-junction compensation 25 °C || +/- 5 °C thermocouple S with internal cold-junction compensation 60 °C || +/- 5.1 °C thermocouple J with internal cold-junction compensation 25 °C || +/- 5.5 °C thermocouple K with internal cold-junction compensation 60 °C || +/- 6.4 °C thermocouple T with internal cold-junction compensation 60 °C || +/- 6.8 °C thermocouple B with internal cold-junction compensation 60 °C || +/- 6.8 °C thermocouple E with internal cold-junction compensation 60 °C || +/- 7 °C thermocouple J with internal cold-junction compensation 60 °C |
| Measurement Resolution | 0.01 mV voltage || 0.1 °C or 0.1 °F temperature probe || 0.1 °C or 0.1 °F thermocouple |
| Range Of Product | Modicon STB distributed I/O solution |
| Type Of Filter | single low pass input filter 25 Hz |
| Product Or Component Type | standard analog input kit |
| Analogue Input Number | 2 |
| Analogue Input Resolution | 15 bits + sign |
| Kit Composition | STBART0200 module || STBXTS1100, 6-terminal screw type connector || STBXBA1000 base || STBXTS2100, 6-terminal spring clamp connector |
| Analogue Input Type | voltage +/- 80 mV || temperature probe -100...+260 °C Cu 10 2, 3 or 4 wires IEC || temperature probe -100...+450 °C Pt 100 2, 3 or 4 wires US/JIS || temperature probe -100...+450 °C Pt 1000 2, 3 or 4 wires US/JIS || temperature probe -200...+850 °C Pt 100 2, 3 or 4 wires IEC || temperature probe -200...+850 °C Pt 1000 2, 3 or 4 wires IEC || temperature probe -60...+180 °C Ni 100 2, 3 or 4 wires IEC || temperature probe -60...+180 °C Ni 1000 2, 3 or 4 wires IEC || thermocouple +130...+1820 °C thermocouple B || thermocouple -200...+760 °C thermocouple J || thermocouple -270...+1000 °C thermocouple E || thermocouple -270...+1370 °C thermocouple K || thermocouple -270...+400 °C thermocouple T || thermocouple -50...+1665 °C thermocouple R || thermocouple -50...+1665 °C thermocouple S |
Nasze wcześniej używane produkty i opcje naprawy są objęte 12-miesięczną gwarancją Obso.
„Super obsługa! Wszystko zostało przetworzone bardzo szybko i kompetentnie, a osobiste wsparcie było doskonałe. Zawsze ponownie wybrałbym Obso Automation! Wielkie dzięki za świetne wsparcie.” - MJ
W razie potrzeby dostępne są również standardowe opcje dostawy.
„Profesjonalny, uprzejmy i dokładny. Przestarzała część wyceniona tego samego dnia i dostarczona następnego” - PT
1
Step 1
Część dodana do zapytania
2
Krok 2
Twój osobisty opiekun klienta już się tym zajmuje, zapewniając szybką reakcję i bezkonkurencyjną obsługę.
3
Krok 3
Nie tylko przetwarzamy zamówienia – gwarantujemy sprawną dostawę, pełną przejrzystość i zero bólu głowy.
4
Krok 4
Nie bez powodu zaufało nam ponad 10 000 klientów. Uzyskaj wycenę już teraz i doświadcz automatyzacji bez ryzyka, opóźnień i niepewności.
Google Reviews