LU2B32FU

Schneider Electric

Reversing power base, TeSys Ultra, 3P, 32A/690V, coil 110-240VAC/DC

Disponibile

Richiedi un preventivo adesso

  • "TeSys U standard reversing power base, 3 poles (3NO), rated 32A/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 15kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a \"all in one\" reversing starter controller with basic or advanced protection and control functions. It is equipped with a reverser module LU2MB0FU to be supplied with 110-240V AC / 110-220V DC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh)."
Per saperne di più arrow Weniger lesen arrow
Specification Value
Product Certifications CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
Height 224 mm
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Maximum Operating Rate 3600 cyc/h
Connections - Terminals control circuit screw clamp terminals 1 0.34-1.5 mm² flexible with cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² flexible without cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² rigid || control circuit screw clamp terminals 2 0.34-1.5 mm² flexible with cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² flexible without cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² rigid || power circuit screw clamp terminals 1 1-10 mm² rigid || power circuit screw clamp terminals 1 1-6 mm² flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² rigid || power circuit screw clamp terminals 2 1.5-6 mm² flexible without cable end
Net Weight 1.27 kg
Fixing Mode clipped DIN rail) || screw-fixed plate)
[Uimp] Rated Impulse Withstand Voltage 6 kVIEC 60947-6-2
Inrush Restraint Duration 25 ms AC 50/60 Hz || 15 ms DC
Standards EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
[Ui] Rated Insulation Voltage 690 V IEC 60947-6-2 3) || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Typical Current Consumption 1000 mA 110...220 V DC I maximum while closing || 1000 mA 110...240 V AC I maximum while closing
Mechanical Durability 15 Mcycles
Compatibility Code LU2B
Operating Time 150 ms with change of direction power circuit || 35 ms opening control circuit || 75 ms without change of direction power circuit || 50 ms closing control circuit
Width 45 mm
Tightening Torque control circuit 0.8-1.2 N.m flat 5 mm || control circuit 0.8-1.2 N.m Philips no 1 5 mm || power circuit 1.9-2.5 N.m flat 6 mm || power circuit 1.9-2.5 N.m Philips No 2 6 mm || power circuit 1.9-2.5 N.m pozidriv No 2 6 mm
Safe Separation Of Circuit 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
Depth 126 mm
Heat Dissipation 3-3 W control circuit with LUCA, LUCB, LUCC, LUCD || 1.8-1.8 W control circuit with LUCM
[Ics] Rated Service Breaking Capacity 50 kA 230 V || 50 kA 440 V || 10 kA 500 V || 4 kA 690 V
[Ue] Rated Operational Voltage 690 V AC power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Uc] Control Circuit Voltage 110...240 V AC 50/60 Hz || 110...220 V DC
Product Or Component Type reversing power base
[Ith] Conventional Free Air Thermal Current 32 A
Product Name TeSys Ultra
Range TeSys
Utilisation Category AC-43 || AC-44 || AC-41
[Ie] Rated Operational Current 28.5 A <= 440 V || 23 A 500 V || 21 A 690 V
Suitability For Isolation yes
Product Compatibility control unit LUC.X6FU || control unit LUC.1XFU || control unit LUC.05FU || control unit LUC.12FU || control unit LUC.18FU || control unit LUC.32FU
Auxiliary Contacts Type linked contacts 1 NO + 1 NC) IEC 60947-4-1 || mirror contact 1 NC) IEC 60947-1
Poles Description 3P
Control Circuit Voltage Limits 55 V DC drop-out || 55 V AC drop-out || 88...242 V DC in operation || 88...264 V AC in operation
Network Frequency 40...60 Hz
Device Application motor control || motor protection
Device Short Name LU2B
Per saperne di più arrow Weniger lesen arrow
*Gli articoli nuovi sono coperti da una garanzia Obso di 24 mesi.
I nostri articoli usati in precedenza e le opzioni di riparazione sono coperti da 12 mesi di garanzia Obso.


“Servizio super! Tutto è stato elaborato in modo molto rapido e competente e il supporto personale è stato eccellente. Sceglierei sempre di nuovo Obso Automation! Molte grazie per l'ottimo supporto”. - MJ
*La consegna e il ritiro il giorno stesso e successivo sono disponibili per le scorte delle nostre filiali nel Regno Unito e in Olanda. La consegna e il ritiro il giorno successivo e la consegna in 2 giorni sono disponibili per le scorte acquistate dai nostri partner. Nel 90% dei casi, se necessario, possiamo consegnare più velocemente del tempo previsto dal produttore.

Se necessario, sono disponibili anche opzioni standard per la consegna.


“Professionale, cortese e preciso. Pezzo obsoleto quotato il giorno stesso e fornito il giorno successivo” - PT
Siamo accreditati ISO 9001 per garantire la tranquillità del vostro acquisto.

Cosa dicono di noi i nostri clienti

Trustpilot

1

Step 1

    Parte aggiunta per richiesta

    2

    Passo 2

    Il vostro Account Manager personale è già al lavoro, fornendo risposte rapide e un servizio imbattibile.

    3

    Passo 3

    Non ci limitiamo a elaborare gli ordini, ma garantiamo una consegna senza intoppi, piena trasparenza e zero grattacapi.

    4

    Passo 4

    Più di 10.000 clienti si fidano di noi per un motivo. Richiedete subito il vostro preventivo e sperimentate l’automazione senza rischi, ritardi o incertezze.