LU2B32FU
Schneider Electric
Reversing power base, TeSys Ultra, 3P, 32A/690V, coil 110-240VAC/DC
AVAILABLE
GET A QUOTE NOW
- "TeSys U standard reversing power base, 3 poles (3NO), rated 32A/690V, to be completed with a control unit LUC to form a TeSys U reversing starter controller, for 3-phase motor applications up to 15kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a \"all in one\" reversing starter controller with basic or advanced protection and control functions. It is equipped with a reverser module LU2MB0FU to be supplied with 110-240V AC / 110-220V DC, auxiliary signaling contacts (1NO+1NC), a control terminal block, blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh)."
| Specification | Value |
|---|---|
| Product Certifications | CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine |
| Height | 224 mm |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Maximum Operating Rate | 3600 cyc/h |
| Connections - Terminals | control circuit screw clamp terminals 1 0.34-1.5 mm² flexible with cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² flexible without cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² rigid || control circuit screw clamp terminals 2 0.34-1.5 mm² flexible with cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² flexible without cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² rigid || power circuit screw clamp terminals 1 1-10 mm² rigid || power circuit screw clamp terminals 1 1-6 mm² flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² rigid || power circuit screw clamp terminals 2 1.5-6 mm² flexible without cable end |
| Net Weight | 1.27 kg |
| Fixing Mode | clipped DIN rail) || screw-fixed plate) |
| [Uimp] Rated Impulse Withstand Voltage | 6 kVIEC 60947-6-2 |
| Inrush Restraint Duration | 25 ms AC 50/60 Hz || 15 ms DC |
| Standards | EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier |
| [Ui] Rated Insulation Voltage | 690 V IEC 60947-6-2 3) || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1 |
| Typical Current Consumption | 1000 mA 110...220 V DC I maximum while closing || 1000 mA 110...240 V AC I maximum while closing |
| Mechanical Durability | 15 Mcycles |
| Compatibility Code | LU2B |
| Operating Time | 150 ms with change of direction power circuit || 35 ms opening control circuit || 75 ms without change of direction power circuit || 50 ms closing control circuit |
| Width | 45 mm |
| Tightening Torque | control circuit 0.8-1.2 N.m flat 5 mm || control circuit 0.8-1.2 N.m Philips no 1 5 mm || power circuit 1.9-2.5 N.m flat 6 mm || power circuit 1.9-2.5 N.m Philips No 2 6 mm || power circuit 1.9-2.5 N.m pozidriv No 2 6 mm |
| Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N |
| Depth | 126 mm |
| Heat Dissipation | 3-3 W control circuit with LUCA, LUCB, LUCC, LUCD || 1.8-1.8 W control circuit with LUCM |
| [Ics] Rated Service Breaking Capacity | 50 kA 230 V || 50 kA 440 V || 10 kA 500 V || 4 kA 690 V |
| [Ue] Rated Operational Voltage | 690 V AC power circuit |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| [Uc] Control Circuit Voltage | 110...240 V AC 50/60 Hz || 110...220 V DC |
| Product Or Component Type | reversing power base |
| [Ith] Conventional Free Air Thermal Current | 32 A |
| Product Name | TeSys Ultra |
| Range | TeSys |
| Utilisation Category | AC-43 || AC-44 || AC-41 |
| [Ie] Rated Operational Current | 28.5 A <= 440 V || 23 A 500 V || 21 A 690 V |
| Suitability For Isolation | yes |
| Product Compatibility | control unit LUC.X6FU || control unit LUC.1XFU || control unit LUC.05FU || control unit LUC.12FU || control unit LUC.18FU || control unit LUC.32FU |
| Auxiliary Contacts Type | linked contacts 1 NO + 1 NC) IEC 60947-4-1 || mirror contact 1 NC) IEC 60947-1 |
| Poles Description | 3P |
| Control Circuit Voltage Limits | 55 V DC drop-out || 55 V AC drop-out || 88...242 V DC in operation || 88...264 V AC in operation |
| Network Frequency | 40...60 Hz |
| Device Application | motor control || motor protection |
| Device Short Name | LU2B |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews