TPRST009

Motor starter, TeSys island, 15A at AC-1, 9A at AC-3, 4kW, 5hp, DOL type

Disponible

Obtenga una cotización ahora

TeSys island direct starter, 3 poles, 9A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 9A and motors up to 4kW@400V / 5hp@480V. It provides motor protection functions including thermal overload (setting 0.18-9A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Más información arrow Leer más arrow
Specification Value
Mounting Mode horizontal and vertical 35 mm symmetrical DIN rail)
Height 116 mm
Product Certifications EAC || CSA || CCC || UL
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Standards EN/IEC 60947-1 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
Connections - Terminals screw-clamp terminals 1 1-4 mm² AWG 16...AWG 12)rigid || screw-clamp terminals 2 1-4 mm² AWG 16...AWG 12)rigid || screw-clamp terminals 1 1.5-4 mm² AWG 16...AWG 12)flexible without cable end || screw-clamp terminals 2 1.5-4 mm² AWG 16...AWG 12)flexible without cable end || screw-clamp terminals 1 1-4 mm² AWG 16...AWG 12)flexible with cable end || screw-clamp terminals 2 1-2.5 mm² AWG 16...AWG 14)flexible with cable end
Net Weight 0.656 kg
Metering Type time device ON || time device switch ON || number of faults || number of switching cycles || number of device power cycles || average current Iavg || average voltage Vavg || max current Imax || max voltage Vmax || active and reactive power with voltage module || active and reactive energy with voltage module || true power factor with voltage module
Maximum Operating Rate 3600 cyc/mn AC-3
Local Signalling for DS (device status) 1 LED (green/red) || for LS (load status) 1 LED (green/red)
Electrical Durability 2 Mcycles 9 A AC-3 440 V || 1.2 Mcycles 15 A AC-1 440 V
Mechanical Durability 30 Mcycles
Operating Time < 100 ms closing || < 30 ms opening
Width 45 mm
Depth 115 mm
Tightening Torque 1.7-1.7 N.m flat Ø 6 mm || 1.7-1.7 N.m Philips No 2
Protection Type thermal overload protection || motor overheat || overcurrent || undercurrent || jam || long start || stall || rapid cycle lockout || phase sequence || rapid restart lockout || phase reversal || phase loss || phase unbalance || ground current
Current Consumption 160 mA contactor sealed || 160 mA contactor closing
Power Dissipation In W 3.5 W at Ie AC-3
Power Dissipation Per Pole 0.2 W AC-3 - Ith 9 A || 0.56 W AC-1 - Ith 15 A
Average Impedance 2.5 mOhm - Ith 15 A 50 Hz
Reset remotely or automatically
[Ith] Conventional Free Air Thermal Current 15 A (at 50 °C)
[Uc] Control Circuit Voltage 24 V DC supplied by the bus coupler
Rated Breaking Capacity 250 A at 440 V conforming to IEC 60947
Product Or Component Type motor starter
Irms Rated Making Capacity 250 A at 440 V conforming to IEC 60947
Product Name TeSys island
Thermal Overload Class class 5…30
[Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947-1
Range TeSys
Device Presentation direct starter connected to an automation controller through a bus coupler || operational only when connected to a bus coupler
Motor Starter Type direct on line
Utilisation Category AC-1 || AC-2 || AC-3 || AC-4
Function Available upstream voltage presence detection || electrical line and load protection || power and energy monitoring when connected with TPRVM voltage module
[Ie] Rated Operational Current 9 A (at <50 °C) at <= 440 V AC-3 || 15 A (at <50 °C) at <= 440 V AC-1
Overvoltage Category III
Thermal Protection Adjustment Range 0.18-9 A
Product Compatibility TPRBC bus coupler || TPRVM voltage interface module
[Ue] Rated Operational Voltage <= 690 V AC 47...63 Hz
Maximum Horse Power Rating 0.33 hp at 120 V AC 60 Hz for 1 phase motors || 1 hp at 240 V AC 60 Hz for 1 phase motors || 2 hp at 208 V AC 60 Hz for 3 phase motors || 2 hp at 240 V AC 60 Hz for 3 phase motors || 5 hp at 480 V AC 60 Hz for 3 phase motors || 7.5 hp at 600 V AC 60 Hz for 3 phase motors
Motor Power Kw 2.2 kW at 230 V 50 Hz (AC-3) || 4 kW at 380...415 V 50 Hz (AC-3) || 4 kW at 440 V 50 Hz (AC-3) || 5.5 kW at 500 V 50 Hz (AC-3) || 5.5 kW at 690 V 50 Hz (AC-3)
[Ui] Rated Insulation Voltage 690 V IEC 60947-4-1 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Device Short Name TPRST
Poles Description 3P 3 NO
[Icw] Rated Short-Time Withstand Current 210 A 40 °C - 1 s || 105 A 40 °C - 10 s || 61 A 40 °C - 1 min || 30 A 40 °C - 10 min
Más información arrow Leer más arrow
*Los artículos nuevos tienen hasta 24 meses de garantía Obso.
Nuestros artículos usados y opciones de reparación tienen 12 meses de garantía Obso.


«¡Súper servicio! Todo se tramitó de forma muy rápida y competente y la asistencia personal fue excelente. Siempre volvería a elegir Obso Automation. Muchas gracias por el gran apoyo». - MJ
*Entrega y recogida el mismo día y al día siguiente en nuestras sucursales del Reino Unido y Países Bajos. La entrega y recogida al día siguiente y la entrega en 2 días están disponibles para las existencias procedentes de nuestros socios. En el 90% de los casos, podemos entregar más rápido que el tiempo estimado de llegada del fabricante cuando sea necesario.

Si lo desea, también disponemos de opciones de entrega estándar.


«Profesional, cortés y preciso. Pieza obsoleta presupuestada el mismo día y suministrada al día siguiente» - PT
Contamos con la acreditación ISO 9001 para que usted esté tranquilo con su compra.

Que dicen los clientes sobre nosotros

Trustpilot

1

Step 1

    Parte agregado para la investigación

    2

    Paso 2

    Su gestor de cuenta personal ya está en ello, ofreciéndole respuestas rápidas y un servicio inmejorable.

    3

    Paso 3

    No nos limitamos a tramitar pedidos: garantizamos una entrega fluida, total transparencia y cero quebraderos de cabeza.

    4

    Paso 4

    Nuestros más de 10.000 clientes confían en nosotros por una razón. Obtenga su presupuesto ahora y experimente la automatización sin riesgos, retrasos ni incertidumbre.