| Specification | Value |
|---|---|
| Mounting Mode | horizontal and vertical 35 mm symmetrical DIN rail) |
| Height | 116 mm |
| Product Certifications | EAC || CSA || CCC || UL |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Standards | EN/IEC 60947-1 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 |
| Connections - Terminals | screw-clamp terminals 1 1-4 mm² AWG 16...AWG 12)rigid || screw-clamp terminals 2 1-4 mm² AWG 16...AWG 12)rigid || screw-clamp terminals 1 1.5-4 mm² AWG 16...AWG 12)flexible without cable end || screw-clamp terminals 2 1.5-4 mm² AWG 16...AWG 12)flexible without cable end || screw-clamp terminals 1 1-4 mm² AWG 16...AWG 12)flexible with cable end || screw-clamp terminals 2 1-2.5 mm² AWG 16...AWG 14)flexible with cable end |
| Net Weight | 0.656 kg |
| Metering Type | time device ON || time device switch ON || number of faults || number of switching cycles || number of device power cycles || average current Iavg || average voltage Vavg || max current Imax || max voltage Vmax || active and reactive power with voltage module || active and reactive energy with voltage module || true power factor with voltage module |
| Maximum Operating Rate | 3600 cyc/mn AC-3 |
| Local Signalling | for DS (device status) 1 LED (green/red) || for LS (load status) 1 LED (green/red) |
| Electrical Durability | 2 Mcycles 9 A AC-3 440 V || 1.2 Mcycles 15 A AC-1 440 V |
| Mechanical Durability | 30 Mcycles |
| Operating Time | < 100 ms closing || < 30 ms opening |
| Width | 45 mm |
| Depth | 115 mm |
| Tightening Torque | 1.7-1.7 N.m flat Ø 6 mm || 1.7-1.7 N.m Philips No 2 |
| Protection Type | thermal overload protection || motor overheat || overcurrent || undercurrent || jam || long start || stall || rapid cycle lockout || phase sequence || rapid restart lockout || phase reversal || phase loss || phase unbalance || ground current |
| Current Consumption | 160 mA contactor sealed || 160 mA contactor closing |
| Power Dissipation In W | 3.5 W at Ie AC-3 |
| Power Dissipation Per Pole | 0.2 W AC-3 - Ith 9 A || 0.56 W AC-1 - Ith 15 A |
| Average Impedance | 2.5 mOhm - Ith 15 A 50 Hz |
| Reset | remotely or automatically |
| [Ith] Conventional Free Air Thermal Current | 15 A (at 50 °C) |
| [Uc] Control Circuit Voltage | 24 V DC supplied by the bus coupler |
| Rated Breaking Capacity | 250 A at 440 V conforming to IEC 60947 |
| Product Or Component Type | motor starter |
| Irms Rated Making Capacity | 250 A at 440 V conforming to IEC 60947 |
| Product Name | TeSys island |
| Thermal Overload Class | class 5…30 |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-1 |
| Range | TeSys |
| Device Presentation | direct starter connected to an automation controller through a bus coupler || operational only when connected to a bus coupler |
| Motor Starter Type | direct on line |
| Utilisation Category | AC-1 || AC-2 || AC-3 || AC-4 |
| Function Available | upstream voltage presence detection || electrical line and load protection || power and energy monitoring when connected with TPRVM voltage module |
| [Ie] Rated Operational Current | 9 A (at <50 °C) at <= 440 V AC-3 || 15 A (at <50 °C) at <= 440 V AC-1 |
| Overvoltage Category | III |
| Thermal Protection Adjustment Range | 0.18-9 A |
| Product Compatibility | TPRBC bus coupler || TPRVM voltage interface module |
| [Ue] Rated Operational Voltage | <= 690 V AC 47...63 Hz |
| Maximum Horse Power Rating | 0.33 hp at 120 V AC 60 Hz for 1 phase motors || 1 hp at 240 V AC 60 Hz for 1 phase motors || 2 hp at 208 V AC 60 Hz for 3 phase motors || 2 hp at 240 V AC 60 Hz for 3 phase motors || 5 hp at 480 V AC 60 Hz for 3 phase motors || 7.5 hp at 600 V AC 60 Hz for 3 phase motors |
| Motor Power Kw | 2.2 kW at 230 V 50 Hz (AC-3) || 4 kW at 380...415 V 50 Hz (AC-3) || 4 kW at 440 V 50 Hz (AC-3) || 5.5 kW at 500 V 50 Hz (AC-3) || 5.5 kW at 690 V 50 Hz (AC-3) |
| [Ui] Rated Insulation Voltage | 690 V IEC 60947-4-1 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1 |
| Device Short Name | TPRST |
| Poles Description | 3P 3 NO |
| [Icw] Rated Short-Time Withstand Current | 210 A 40 °C - 1 s || 105 A 40 °C - 10 s || 61 A 40 °C - 1 min || 30 A 40 °C - 10 min |
Auf unsere gebrauchten Artikel und Reparaturoptionen gewähren wir 12 Monate Obso-Garantie.
„Super Service! Alles wurde sehr schnell und kompetent abgewickelt und die persönliche Betreuung war hervorragend. Ich würde mich jederzeit wieder für Obso Automation entscheiden! Vielen Dank für die tolle Unterstützung.“ - MJ
Bei Bedarf sind auch Standardoptionen für die Lieferung verfügbar.
„Professionell, zuvorkommend und genau. Veraltetes Teil am selben Tag angeboten und am nächsten Tag geliefert“ - PT
1
Step 1
Bauteil zur Anfrage hinzugefügt