LV426950
Schneider Electric
standard auxiliary contact, ComPact NSXm, circuit breaker status OF/SD, 1 changeover contact type
Disponible
Obtenga una cotización ahora
- "It is a single standard auxiliary contact that provides two remote information of the circuit breaker status. It is used on Compact NSXm and PowerPact B devices. The OF contact (open/closed) indicates the position of the circuit breaker main contacts. The SD contact (trip indication) indicates if the circuit breaker has tripped. There is one auxiliary contact model for OF and SD information, depending on where it is fitted in the device. This auxiliary is a common point changeover type contact with 1 normally open contact and 1 normally closed contact. The rated current is 5A and the minimum load is 2mA at 17 VDC. Utilization categories are AC12/AC13/DC12/DC13/DC14. Compact NSXm embeds 2 auxiliary contacts and their presence is visible on the front face through green flags. It complies with IEC 60947-5-1 standard."
| Specification | Value |
|---|---|
| Fault Type | overload || short-circuit |
| Auxiliary Connection Terminal | spring |
| [Ith] Conventional Free Air Thermal Current | 5 A |
| Wire Stripping Length | 8 mm for front connection |
| Mounting Mode | clip-on |
| Auxiliary Contacts Type | standard |
| [Ie] Rated Operational Current | AC-12: 5 A at 24 V AC 50/60 Hz || AC-12: 5 A at 48 V AC 50/60 Hz || AC-12: 5 A at 110...127 V AC 50/60 Hz || AC-12: 5 A at 220/240 V AC 50/60 Hz || AC-12: 5 A at 380/440 V AC 50/60 Hz || AC-12: 5 A at 660/690 V AC 50/60 Hz || AC-15: 5 A at 24 V AC 50/60 Hz || AC-15: 5 A at 48 V AC 50/60 Hz || AC-15: 4 A at 110...127 V AC 50/60 Hz || AC-15: 3 A at 220/240 V AC 50/60 Hz || AC-15: 2.5 A at 380/440 V AC 50/60 Hz || AC-15: 0.1 A at 660/690 V AC 50/60 Hz || DC-12: 5 A at 24 V DC 50/60 Hz || DC-12: 2.5 A at 48 V DC 50/60 Hz || DC-12: 0.6 A at 110 V DC 50/60 Hz || DC-12: 0.3 A at 250 V DC || DC-13: 2.5 A at 24 V DC || DC-13: 1.2 A at 48 V DC || DC-13: 0.35 A at 110 V DC || DC-13: 0.05 A at 250 V DC || DC-14: 1 A at 24 V DC || DC-14: 0.2 A at 48 V DC || DC-14: 0.05 A at 110 V DC || DC-14: 0.03 A at 250 V DC |
| Local Signalling | for open/close ON/OFF indication || for relay trip indicator trip indicator |
| Minimum Load | 2 mA 17 V DC |
| Range Compatibility | PowerPact PowerPact B || ComPact ComPact NSXm |
| Product Or Component Type | auxiliary contact |
| Signal Contacts Composition | 1 NO/NC |
| Device Application | breaker status monitoring |
| Device Short Name | SD || OF |
Nuestros artículos usados y opciones de reparación tienen 12 meses de garantía Obso.
«¡Súper servicio! Todo se tramitó de forma muy rápida y competente y la asistencia personal fue excelente. Siempre volvería a elegir Obso Automation. Muchas gracias por el gran apoyo». - MJ
Si lo desea, también disponemos de opciones de entrega estándar.
«Profesional, cortés y preciso. Pieza obsoleta presupuestada el mismo día y suministrada al día siguiente» - PT
1
Step 1
Parte agregado para la investigación
2
Paso 2
Su gestor de cuenta personal ya está en ello, ofreciéndole respuestas rápidas y un servicio inmejorable.
3
Paso 3
No nos limitamos a tramitar pedidos: garantizamos una entrega fluida, total transparencia y cero quebraderos de cabeza.
4
Paso 4
Nuestros más de 10.000 clientes confían en nosotros por una razón. Obtenga su presupuesto ahora y experimente la automatización sin riesgos, retrasos ni incertidumbre.
Google Reviews