LV426950
Schneider Electric
standard auxiliary contact, ComPact NSXm, circuit breaker status OF/SD, 1 changeover contact type
AVAILABLE
GET A QUOTE NOW
- "It is a single standard auxiliary contact that provides two remote information of the circuit breaker status. It is used on Compact NSXm and PowerPact B devices. The OF contact (open/closed) indicates the position of the circuit breaker main contacts. The SD contact (trip indication) indicates if the circuit breaker has tripped. There is one auxiliary contact model for OF and SD information, depending on where it is fitted in the device. This auxiliary is a common point changeover type contact with 1 normally open contact and 1 normally closed contact. The rated current is 5A and the minimum load is 2mA at 17 VDC. Utilization categories are AC12/AC13/DC12/DC13/DC14. Compact NSXm embeds 2 auxiliary contacts and their presence is visible on the front face through green flags. It complies with IEC 60947-5-1 standard."
| Specification | Value |
|---|---|
| Fault Type | overload || short-circuit |
| Auxiliary Connection Terminal | spring |
| [Ith] Conventional Free Air Thermal Current | 5 A |
| Wire Stripping Length | 8 mm for front connection |
| Mounting Mode | clip-on |
| Auxiliary Contacts Type | standard |
| [Ie] Rated Operational Current | AC-12: 5 A at 24 V AC 50/60 Hz || AC-12: 5 A at 48 V AC 50/60 Hz || AC-12: 5 A at 110...127 V AC 50/60 Hz || AC-12: 5 A at 220/240 V AC 50/60 Hz || AC-12: 5 A at 380/440 V AC 50/60 Hz || AC-12: 5 A at 660/690 V AC 50/60 Hz || AC-15: 5 A at 24 V AC 50/60 Hz || AC-15: 5 A at 48 V AC 50/60 Hz || AC-15: 4 A at 110...127 V AC 50/60 Hz || AC-15: 3 A at 220/240 V AC 50/60 Hz || AC-15: 2.5 A at 380/440 V AC 50/60 Hz || AC-15: 0.1 A at 660/690 V AC 50/60 Hz || DC-12: 5 A at 24 V DC 50/60 Hz || DC-12: 2.5 A at 48 V DC 50/60 Hz || DC-12: 0.6 A at 110 V DC 50/60 Hz || DC-12: 0.3 A at 250 V DC || DC-13: 2.5 A at 24 V DC || DC-13: 1.2 A at 48 V DC || DC-13: 0.35 A at 110 V DC || DC-13: 0.05 A at 250 V DC || DC-14: 1 A at 24 V DC || DC-14: 0.2 A at 48 V DC || DC-14: 0.05 A at 110 V DC || DC-14: 0.03 A at 250 V DC |
| Local Signalling | for open/close ON/OFF indication || for relay trip indicator trip indicator |
| Minimum Load | 2 mA 17 V DC |
| Range Compatibility | PowerPact PowerPact B || ComPact ComPact NSXm |
| Product Or Component Type | auxiliary contact |
| Signal Contacts Composition | 1 NO/NC |
| Device Application | breaker status monitoring |
| Device Short Name | SD || OF |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews