| Specification | Value |
|---|---|
| Contacts Type And Composition | 1 NO + 1 NC fault signal || 3 NO |
| Height | 61 mm |
| Connection Pitch | 5.08 mm |
| Permissible Power | 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
| Network And Machine Diagnosis Type | running hours counter/operating time || starting current and time || trip context information || remaining operating time before overload tripping || fault recording || phase fault and earth fault trip counters || event recording || trip history information || waiting time after overload tripping || motor control command recording |
| Pollution Degree | 3 |
| Logic Input Number | 6 |
| Maximum Operating Rate | 1800 cyc/h |
| Connections - Terminals | control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end |
| Input Current | 7 mA |
| Current State 1 Guaranteed | logic input < 15 V 2...15 mA 15 ms |
| Net Weight | 0.53 kg |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 || 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1 |
| Associated Fuse Rating | 4 A gG output || 0.5 A gG control circuit |
| Electromagnetic Compatibility | electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 |
| Measurement Accuracy | 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 5 % active and reactive power || 0,02 current |
| Current State 0 Guaranteed | logic input < 5 V <= 15 mA 5 ms |
| [Ui] Rated Insulation Voltage | 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508 |
| Short-Circuit Withstand | 100 kA conforming to EN/IEC 60947-4-1 |
| Compatibility Code | LTMR |
| Protection Type | earth-leakage protection || overload || reverse polarity protection || thermal protection || overload (long time) || load fluctuation || phase failure || thermal overload protection || power factor variation || locked rotor || phase unbalance |
| Web Services | web server |
| Width | 91 mm |
| Load Current | 5 A 250 V AC logic output || 5 A 30 V DC logic output |
| Tightening Torque | control circuit 0.5-0.6 N.m flat 3 mm |
| Overvoltage Category | III |
| Depth | 122.5 mm |
| Maximum Operating Frequency | 2 Hz |
| Metering Type | temperature || average current Iavg || imbalance current || earth-fault current || phase current I1, I2, I3 RMS |
| Product Or Component Type | motor controller |
| Product Name | TeSys T |
| Measurement Current | 5-100 A |
| Range | TeSys |
| Current Consumption | 56...127 mA |
| [Us] Rated Supply Voltage | 24 V DC |
| Communication Port Protocol | DeviceNet |
| Bus Type | DeviceNet ISO 1198 1...64 125...500 kbit/s, terminal block 4 twisted shielded pairs cable |
| Supply Voltage Limits | 20.4-26.24 V DC |
| Device Application | equipment monitoring and control |
| Device Short Name | LTMR |
Nuestros artículos usados y opciones de reparación tienen 12 meses de garantía Obso.
«¡Súper servicio! Todo se tramitó de forma muy rápida y competente y la asistencia personal fue excelente. Siempre volvería a elegir Obso Automation. Muchas gracias por el gran apoyo». - MJ
Si lo desea, también disponemos de opciones de entrega estándar.
«Profesional, cortés y preciso. Pieza obsoleta presupuestada el mismo día y suministrada al día siguiente» - PT
1
Step 1
Parte agregado para la investigación
2
Paso 2
Su gestor de cuenta personal ya está en ello, ofreciéndole respuestas rápidas y un servicio inmejorable.
3
Paso 3
No nos limitamos a tramitar pedidos: garantizamos una entrega fluida, total transparencia y cero quebraderos de cabeza.
4
Paso 4
Nuestros más de 10.000 clientes confían en nosotros por una razón. Obtenga su presupuesto ahora y experimente la automatización sin riesgos, retrasos ni incertidumbre.
Google Reviews