LC2D50G7

Schneider Electric

Reversing Contactor, TeSys Deca, 3P(3NO), AC-3, IEC, <=440V, 50A, 120V AC 60Hz coil

Disponible

Obtenga una cotización ahora

-

Specification Value
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
Interlocking Type mechanical
Minimum Switching Current 5 mA for control circuit
[Ue] Rated Operational Voltage power circuit <= 1000 V AC 25...400 Hz
Height 132 mm
Power Dissipation Per Pole 3.7 W AC-3 - Ith 80 A
Average Impedance Ith 80 A 50 Hz for power circuit
Auxiliary Contact Composition 1 NO + 1 NC
Control Circuit Voltage Limits drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C) || operational: 0.8...1.1 Uc at 50 Hz (at <60 °C) || operational: 0.85...1.1 Uc at 60 Hz (at <60 °C)
[Ith] Conventional Free Air Thermal Current 10 A (at 60 °C) for control circuit || 80 A (at 60 °C) for power circuit
Mounting Support plate || rail
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance > 10 MOhm for control circuit
Rated Breaking Capacity 900 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity 140 A AC for control circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
Associated Fuse Rating 10 A gG for control circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit
Net Weight 2.4 kg
Inrush Power In Va 200-200 VA cos phi 0.75 (at 20 °C) || 220-220 VA cos phi 0.75 (at 20 °C)
[Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
Coil Technology without built-in bidirectional peak limiting diode suppressor
Flame Retardance V1 conforming to UL 94
Minimum Switching Voltage 17 V for control circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Tightening Torque control circuit 1.7 N.m 1-2.5 mm² flat Ø 6 mm || control circuit 1.7 N.m 1-2.5 mm² Philips No 2 || control circuit 1.7 N.m 1-4 mm² flat Ø 6 mm || control circuit 1.7 N.m 1-4 mm² Philips No 2 || power circuit 5 N.m 1-25 mm² hexagonal || power circuit 8 N.m 1-35 mm² hexagonal
Assembly Style ready assembled
Mechanical Durability 6000000 cycles
Auxiliary Contacts Type mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Hold-In Power Consumption In Va 20-20 VA 50 Hz cos phi 0.3 (at 20 °C) || 22-22 VA 60 Hz cos phi 0.3 (at 20 °C) || 26-26 VA 50 Hz cos phi 0.3 (at 20 °C) || 26-26 VA 60 Hz cos phi 0.3 (at 20 °C)
Operating Time 12...26 ms closing || 4...19 ms opening
Width 165 mm
Overvoltage Category III
Depth 142 mm
[Ui] Rated Insulation Voltage control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1
Protective Cover with
Control Circuit Type AC
[Uc] Control Circuit Voltage 120 V AC 60 Hz
Range Of Product TeSys Deca
Contactor Application motor control
Product Or Component Type reversing contactor
Connections - Terminals control circuit 1 1-4 mm²flexible with cable end || power circuit 2 1-25 mm²flexible with cable end || power circuit 2 1-25 mm²flexible without cable end || power circuit 2 1-25 mm²solid without cable end || power circuit 2 1-35 mm²flexible with cable end || power circuit 2 1-35 mm²flexible without cable end || power circuit 2 1-35 mm²solid without cable end || control circuit 1 1-4 mm²flexible without cable end || control circuit 1 1-4 mm²solid without cable end || control circuit 2 1-2.5 mm²flexible with cable end || control circuit 2 1-4 mm²flexible without cable end || control circuit 2 1-4 mm²solid without cable end || power circuit 1 1-35 mm²flexible with cable end || power circuit 1 1-35 mm²flexible without cable end || power circuit 1 1-35 mm²solid without cable end
Pole Contact Composition 3 NO
Utilisation Category AC-2 || AC-3 || AC-4
[Ie] Rated Operational Current power circuit 50 A AC AC-3 60 °C)
Poles Description 3P
Motor Power Kw 15 kW 220...240 V AC 50/60 Hz || 22 kW 380...400 V AC 50/60 Hz || 25 kW 415 V AC 50/60 Hz || 30 kW 440 V AC 50/60 Hz || 30 kW 500 V AC 50/60 Hz || 33 kW 660...690 V AC 50/60 Hz
Device Short Name LC2D
Coil Type standard
Más información arrow Leer más arrow
*Los artículos nuevos tienen hasta 24 meses de garantía Obso.
Nuestros artículos usados y opciones de reparación tienen 12 meses de garantía Obso.


«¡Súper servicio! Todo se tramitó de forma muy rápida y competente y la asistencia personal fue excelente. Siempre volvería a elegir Obso Automation. Muchas gracias por el gran apoyo». - MJ
*Entrega y recogida el mismo día y al día siguiente en nuestras sucursales del Reino Unido y Países Bajos. La entrega y recogida al día siguiente y la entrega en 2 días están disponibles para las existencias procedentes de nuestros socios. En el 90% de los casos, podemos entregar más rápido que el tiempo estimado de llegada del fabricante cuando sea necesario.

Si lo desea, también disponemos de opciones de entrega estándar.


«Profesional, cortés y preciso. Pieza obsoleta presupuestada el mismo día y suministrada al día siguiente» - PT
Contamos con la acreditación ISO 9001 para que usted esté tranquilo con su compra.

Que dicen los clientes sobre nosotros

Trustpilot

1

Step 1

    Parte agregado para la investigación

    2

    Paso 2

    Su gestor de cuenta personal ya está en ello, ofreciéndole respuestas rápidas y un servicio inmejorable.

    3

    Paso 3

    No nos limitamos a tramitar pedidos: garantizamos una entrega fluida, total transparencia y cero quebraderos de cabeza.

    4

    Paso 4

    Nuestros más de 10.000 clientes confían en nosotros por una razón. Obtenga su presupuesto ahora y experimente la automatización sin riesgos, retrasos ni incertidumbre.