LC2D50G7

Schneider Electric

Reversing Contactor, TeSys Deca, 3P(3NO), AC-3, IEC, <=440V, 50A, 120V AC 60Hz coil

AVAILABLE

GET A QUOTE NOW

-

Specification Value
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
Interlocking Type mechanical
Minimum Switching Current 5 mA for control circuit
[Ue] Rated Operational Voltage power circuit <= 1000 V AC 25...400 Hz
Height 132 mm
Power Dissipation Per Pole 3.7 W AC-3 - Ith 80 A
Average Impedance Ith 80 A 50 Hz for power circuit
Auxiliary Contact Composition 1 NO + 1 NC
Control Circuit Voltage Limits drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C) || operational: 0.8...1.1 Uc at 50 Hz (at <60 °C) || operational: 0.85...1.1 Uc at 60 Hz (at <60 °C)
[Ith] Conventional Free Air Thermal Current 10 A (at 60 °C) for control circuit || 80 A (at 60 °C) for power circuit
Mounting Support plate || rail
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance > 10 MOhm for control circuit
Rated Breaking Capacity 900 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity 140 A AC for control circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
Associated Fuse Rating 10 A gG for control circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit
Net Weight 2.4 kg
Inrush Power In Va 200-200 VA cos phi 0.75 (at 20 °C) || 220-220 VA cos phi 0.75 (at 20 °C)
[Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
Coil Technology without built-in bidirectional peak limiting diode suppressor
Flame Retardance V1 conforming to UL 94
Minimum Switching Voltage 17 V for control circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Tightening Torque control circuit 1.7 N.m 1-2.5 mm² flat Ø 6 mm || control circuit 1.7 N.m 1-2.5 mm² Philips No 2 || control circuit 1.7 N.m 1-4 mm² flat Ø 6 mm || control circuit 1.7 N.m 1-4 mm² Philips No 2 || power circuit 5 N.m 1-25 mm² hexagonal || power circuit 8 N.m 1-35 mm² hexagonal
Assembly Style ready assembled
Mechanical Durability 6000000 cycles
Auxiliary Contacts Type mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Hold-In Power Consumption In Va 20-20 VA 50 Hz cos phi 0.3 (at 20 °C) || 22-22 VA 60 Hz cos phi 0.3 (at 20 °C) || 26-26 VA 50 Hz cos phi 0.3 (at 20 °C) || 26-26 VA 60 Hz cos phi 0.3 (at 20 °C)
Operating Time 12...26 ms closing || 4...19 ms opening
Width 165 mm
Overvoltage Category III
Depth 142 mm
[Ui] Rated Insulation Voltage control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1
Protective Cover with
Control Circuit Type AC
[Uc] Control Circuit Voltage 120 V AC 60 Hz
Range Of Product TeSys Deca
Contactor Application motor control
Product Or Component Type reversing contactor
Connections - Terminals control circuit 1 1-4 mm²flexible with cable end || power circuit 2 1-25 mm²flexible with cable end || power circuit 2 1-25 mm²flexible without cable end || power circuit 2 1-25 mm²solid without cable end || power circuit 2 1-35 mm²flexible with cable end || power circuit 2 1-35 mm²flexible without cable end || power circuit 2 1-35 mm²solid without cable end || control circuit 1 1-4 mm²flexible without cable end || control circuit 1 1-4 mm²solid without cable end || control circuit 2 1-2.5 mm²flexible with cable end || control circuit 2 1-4 mm²flexible without cable end || control circuit 2 1-4 mm²solid without cable end || power circuit 1 1-35 mm²flexible with cable end || power circuit 1 1-35 mm²flexible without cable end || power circuit 1 1-35 mm²solid without cable end
Pole Contact Composition 3 NO
Utilisation Category AC-2 || AC-3 || AC-4
[Ie] Rated Operational Current power circuit 50 A AC AC-3 60 °C)
Poles Description 3P
Motor Power Kw 15 kW 220...240 V AC 50/60 Hz || 22 kW 380...400 V AC 50/60 Hz || 25 kW 415 V AC 50/60 Hz || 30 kW 440 V AC 50/60 Hz || 30 kW 500 V AC 50/60 Hz || 33 kW 660...690 V AC 50/60 Hz
Device Short Name LC2D
Coil Type standard
Read more arrow Read less arrow
*New items come with up to 24 month Obso Warranty
Our previously used items and repair options come with 12 months Obso Warranty.


"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
*Same & Next Day Delivery & Collection is available for stock from our UK and NL branches. Next-day delivery collection and 2 day delivery is available for stock sourced from our partners. In 90% of cases, we can deliver faster than the manufacturer’s ETA where required.

Standard options for delivery are also available where required.


"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
We are ISO 9001 accredited so you have peace of mind with your purchase.

What our customers say about us

Trustpilot

1

Step 1

    Part added for enquiry

    2

    Step 2

    Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.

    3

    Step 3

    We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.

    4

    Step 4

    Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.