ATV212HU30N4

variable speed drive, Altivar 212, 3kW, 480V, 3 phases, with EMC, IP21

Verfügbar

Jetzt Angebot einholen

This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 3kW and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 3.35kg and its dimensions are, 142mm wide, 184mm high, 150mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet.
Lesen Sie mehr arrow Weniger lesen arrow
Specification Value
Prospective Line Isc 5 kA
Electrical Connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14 || L1/R, L2/S, L3/T terminal 6-6 mm² / AWG 10
Network Frequency 47.5...63 Hz
Discrete Input Logic positive logic (source) F, R, RES), <= 5 V, >= 11 V || negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Type Of Cable without mounting kit 1 IEC cable 45 °C, copper 90 °C / XLPE/EPR || without mounting kit 1 IEC cable 45 °C, copper 70 °C / PVC || with UL Type 1 kit 3 UL 508 cable 40 °C, copper 75 °C / PVC
Height 184 mm
Acceleration And Deceleration Ramps automatic based on the load || linear adjustable separately from 0.01 to 3200 s
Analogue Output Type FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits || FM switch-configurable current 0...20 mA 970 Ohm 10 bits
Speed Drive Output Frequency 0.5-200 Hz
Discrete Output Type configurable relay logic FLA, FLC) NO - 100000 cycles || configurable relay logic FLB, FLC) NC - 100000 cycles || configurable relay logic RY, RC) NO - 100000 cycles
Transmission Frame RTU
Torque Accuracy +/- 15 %
Asynchronous Motor Control Profile voltage/frequency ratio, 2 points || voltage/frequency ratio, 5 points || voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) || voltage/frequency ratio - Energy Saving, quadratic U/f || flux vector control without sensor, standard
Maximum Switching Current 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R) || 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R) || 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R) || 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Communication Service write multiple registers (16) 2 words maximum || read holding registers (03) 2 words maximum || time out setting from 0.1 to 100 s || read device identification (43) || monitoring inhibitable || write single register (06)
Transient Overtorque 120-120 % of nominal motor torque +/- 10 % 60 s
Insulation Resistance >= 1 mOhm 500 V DC for 1 minute
Response Time FM 2 ms +/- 0.5 ms analog || FLA, FLC 7 ms +/- 0.5 ms discrete || FLB, FLC 7 ms +/- 0.5 ms discrete || RY, RC 7 ms +/- 0.5 ms discrete
Data Format 8 bits, 1 stop, odd even or no configurable parity
Apparent Power 5.5 kVA 380 V
Dielectric Strength 3535 V DC between earth and power terminals || 5092 V DC between control and power terminals
Power Range 2.2-3 kW 380-440 V 3 phase || 2.2-3 kW 480-500 V 3 phase
Net Weight 3.35 kg
Type Of Polarization no impedance
Frequency Resolution display unit 0.1 Hz || analog input 0.024/50 Hz
Accuracy +/- 0.6 % VIA) for a temperature variation 60 °C || +/- 0.6 % VIB) for a temperature variation 60 °C || +/- 1 % FM) for a temperature variation 60 °C
Switching Frequency 6...16 kHz adjustable || 12...16 kHz with derating factor
Maximum Transient Current 7.9 A 60 s
Connector Type 1 open style || 1 RJ45
Analogue Input Number 2
Functionality mid
Motor Slip Compensation adjustable || automatic whatever the load || not available in voltage/frequency ratio motor control
Motor Starter Type variable speed drive
Discrete Output Number 2
Minimum Switching Current 3 mA 24 V DC configurable relay logic
Analogue Output Number 1
Physical Interface 2-wire RS 485
Power Dissipation In W 137 W
Continuous Output Current 7.2 A 380 V || 7.2 A 460 V
Number Of Addresses 1-247
Tightening Torque 1.3 N.m, 11.5 lb.in L1/R, L2/S, L3/T) || 0.6 N.m VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
Discrete Input Type F programmable 24 V DC level 1 PLC 4700 Ohm || R programmable 24 V DC level 1 PLC 4700 Ohm || RES programmable 24 V DC level 1 PLC 4700 Ohm
Speed Range 1-10
Isolation electrical between power and control
Local Signalling for DC bus energized 1 LED (red)
Linearity Error VIA +/- 0.15 % of maximum value input || VIB +/- 0.15 % of maximum value input || FM +/- 0.2 % output
Specific Application HVAC
Output Voltage <= power supply voltage
Nominal Switching Frequency 12 kHz
Width 142 mm
Transmission Rate 9600 bps or 19200 bps
Braking To Standstill by DC injection
Air Flow 47 m3/h
Depth 150 mm
Protection Type overheating protection drive || thermal power stage drive || short-circuit between motor phases drive || input phase breaks drive || overcurrent between output phases and earth drive || overvoltages on the DC bus drive || break on the control circuit drive || against exceeding limit speed drive || line supply overvoltage and undervoltage drive || line supply undervoltage drive || against input phase loss drive || thermal protection motor || motor phase break motor || with PTC probes motor
Supply internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection || internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
Analogue Input Type VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits || VIB configurable PTC probe 0...6 probes 1500 Ohm || VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
Discrete And Process Manufacturing building - HVAC compressor for scroll || building - HVAC fan || building - HVAC pump
Sampling Duration 2 ms +/- 0.5 ms F discrete || 2 ms +/- 0.5 ms R discrete || 2 ms +/- 0.5 ms RES discrete || 3.5 ms +/- 0.5 ms VIA analog || 22 ms +/- 0.5 ms VIB analog
Speed Accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Option Card communication card LonWorks
Product Destination asynchronous motors
Range Of Product Altivar 212
Product Or Component Type variable speed drive
Ip Degree Of Protection IP21
Motor Power Kw 3 kW
Phase 3 phase
Line Current 4.9 A 480 V || 6.2 A 380 V
[Us] Rated Supply Voltage 380...480 V - 15...10 %
Communication Port Protocol METASYS N2 || LonWorks || Modbus || BACnet || APOGEE FLN
Supply Voltage Limits 323-528 V
Product Specific Application pumps and fans in HVAC
Emc Filter Class C2 EMC filter integrated
Maximum Horse Power Rating 4 hp
Device Short Name ATV212
Supply Frequency 50...60 Hz - 5...5 %
Lesen Sie mehr arrow Weniger lesen arrow
*Neue Artikel haben bis zu 24 Monate Obso-Garantie
Auf unsere gebrauchten Artikel und Reparaturoptionen gewähren wir 12 Monate Obso-Garantie.


„Super Service! Alles wurde sehr schnell und kompetent abgewickelt und die persönliche Betreuung war hervorragend. Ich würde mich jederzeit wieder für Obso Automation entscheiden! Vielen Dank für die tolle Unterstützung.“ - MJ
*Die Lieferung und Abholung am selben oder nächsten Tag ist für Lagerbestände in unseren Niederlassungen in Großbritannien und den Niederlanden möglich. Abholung am nächsten Tag und Lieferung innerhalb von 2 Tagen ist möglich, wenn die Ware von unseren Partnern bezogen wird. In 90 % der Fälle können wir bei Bedarf schneller liefern als die vom Hersteller angegebene Lieferfrist.

Bei Bedarf sind auch Standardoptionen für die Lieferung verfügbar.


„Professionell, zuvorkommend und genau. Veraltetes Teil am selben Tag angeboten und am nächsten Tag geliefert“ - PT
Wir sind ISO 9001-zertifiziert, so dass Sie sich bei Ihrem Kauf keine Sorgen machen müssen.

Was unsere Kunden über uns sagen

Trustpilot

1

Step 1

    Bauteil zur Anfrage hinzugefügt

    2

    Seite 2

    Ihr persönlicher Kundenbetreuer ist bereits dabei und sorgt für schnelle Antworten und einen unschlagbaren Service.

    3

    Seite 3

    Wir wickeln nicht nur Aufträge ab – wir garantieren eine reibungslose Lieferung, volle Transparenz und keine Kopfschmerzen.

    4

    Seite 4

    Mehr als 10.000 Kunden vertrauen uns aus gutem Grund. Fordern Sie jetzt Ihr Angebot an und erleben Sie Automatisierung ohne Risiko, Verzögerungen oder Unsicherheit.