XPSMC32Z
Schneider Electric
safety controller, Harmony XPS MC, 24V DC, 32 inputs, 46 LEDs signalling
AVAILABLE
GET A QUOTE NOW
- "This product is part of preventa XPCMC configurable safety controller range. It is a configurable safety controller. It is supplied with 24 V DC. It has 32 safety inputs. It conforms to Category 4 maximum conforming to EN 954-1/EN/ISO 13849-1, PLE safety level conforming to EN/ISO 13849-1 and SIL 3 level conforming to IEC 61508. It embeds 1 RJ45 port for a serial link communication with Modbus protocol. The transmission rate are 1200bps, 2400 bps, 4800bps, 9600bps or 19200bps. This product measures 153mm depth, 151.5mm height, and 74mm width. It weighs 0.84kg. This safety controller is designed for monitoring multiple safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. This product is certified by CSA, UL and T\u00dcV. It conforms to EN 954-1/EN/ISO 13849-1, EN/IEC 61496-1, IEC 61508, EN/IEC 60204-1, EN 1760-1/ISO 13856-1, EN 574/ISO 13851 and EN/IEC 60947-5-1 standards. The Safety controller XPSMC is configurable and addressable using software XPSMCWIN running on a PC and using a USB/RJ45 cable type TCSMCNAM3M002P to connect to the safety controller. It installs with a mounting plate for mounting on rail. Preventa XPSMC configurable safety controller is designed to provide a solution for safety applications requiring conformity to Performance Level PL e/Category 4 EN ISO 13849-1 and SIL3 EN/IEC 61508. The configurable safety controller consists of 6 variants with 16 or 32 digital inputs and 8 digital outputs and communication possibilities of Modbus RTL Serial, Profibus DP and CANopen."
| Specification | Value |
|---|---|
| Height | 151.5 mm |
| [Ith] Conventional Free Air Thermal Current | 16 A relay output || 6.5 A static output circuit |
| Mounting Support | mounting plate |
| Output Thermal Current | 4 A for both outputs simultaneously || 6 A for 1 output and 2 A for the other relay output |
| Power Consumption In W | 12 W |
| Minimum Output Voltage | 17 V relay output |
| Response Time | configurable : 20 ms or 30 ms with software XPSMCWIN |
| Data Format | 1 start bit/8 data bits || 1 stop bit even or odd || 2 stop bits without parity || RTU (Remote Terminal Unit) mode |
| Minimum Output Current | 10 mA relay output |
| Associated Fuse Rating | 16 A gL power supply || 4 A gL relay output || 6 A fast blow relay output |
| [Uimp] Rated Impulse Withstand Voltage | 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1 |
| Net Weight | 0.84 kg |
| Output Type | 2 relays, 2 NO contacts (4 NO total) || solid state, 6, volt-free |
| [Ui] Rated Insulation Voltage | 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1 |
| Parity | even Modbus || no Modbus || odd Modbus |
| Exchange Size | 14 words |
| Supported Modbus Function | 01 8-bit output data/32-bit input data || 02 32-bit input data/8-bit output data || 03 information and errors |
| Method Of Access | slave |
| Local Signalling | 46 LEDs |
| Number Of Addresses | 1-247 Modbus |
| Maximum Line Resistance | 100 Ohm <2000 m |
| Input Protection Type | external fuse 16 A |
| Width | 74 mm |
| Depth | 153 mm |
| [Uc] Control Circuit Voltage | 28.8 V |
| Function Of Module | dynamic monitoring of hydraulic valves on linear presses || eccentric press || emergency stop monitoring, with or without time delay, 1 or 2-channel wiring || enabling switch monitoring, 2 or 3 contacts || foot switch monitoring || guard monitoring for injection presses and blowing machines || guard monitoring with 1 or 2 limit switches || hydraulic press || magnetic switch monitoring category 4 EN/IEC 61496 || monitoring safety stop at top dead centre on eccentric press category 3 EN 574/ISO 13851 || muting function of light curtains || position selector || safety mat monitoring || safety time delays || shaft/chain breaking monitor || zero speed detection || light curtain monitoring category 4 IEC 61496 || two-hand control category 3 EN 574/ISO 13851 |
| Synchronisation Time Between Inputs | depending on configuration selected |
| Breaking Capacity | 2 A 24 V static output circuit || 1.5 A 24 V DC-13)50 ms relay output |
| Breaking Capacity | 180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output |
| Product Certifications | CSA || UL || TÜV |
| [Us] Rated Supply Voltage | 24 V DC - 20...20 % |
| Range Of Product | Preventa Safety automation |
| Standards | EN 954-1/EN/ISO 13849-1 || IEC 61496-1 || IEC 60947-5-1 || IEC 61508 || EN 1760-1/ISO 13856-1 || EN 574/ISO 13851 || IEC 60204-1 |
| Number Of Inputs | 32 |
| Product Or Component Type | configurable safety controller |
| Safety Module Name | XPSMC |
| Type Of Start | configurable |
| Communication Port Protocol | Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps |
| Safety Use Category | category 4 maximum EN 954-1/EN/ISO 13849-1 || PLE maximum ISO 13849-1 || SIL 3 maximum IEC 61508 |
| Safety Level | can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 || can reach SIL 3 IEC 61508 |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews