  • "TeSys U advanced power base, 3 poles (3NO), 32A/690V, to be completed with a control unit LUC to form a TeSys U starter controller, for 3-phase motor applications up to 15kW@400V. Base composed of power contacts, control coil, rotary handle, with a modular design for additional modules to form a \"all in one\" starter controller with basic or advanced protection and control functions. It is equipped with auxiliary signaling contacts (1NO+1NC), a control terminal block, and blanking shutters covering the empty cavities. It provides a high breaking capacity Icu 50kA@400V, start-stop control guaranteed for 3600 cycles/hour. Very compact (45mm width), DIN-rail mounting and screw fixing, with a padlockable rotary handle. Certified when used in conjunction with a LUC control unit (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh)."
Read more arrow Read less arrow
Specification Value
Product Certifications CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
Height 154 mm
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Maximum Operating Rate 3600 cyc/h
Connections - Terminals power circuit screw clamp terminals 1 1-10 mm² rigid || power circuit screw clamp terminals 1 1-6 mm² flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² rigid || power circuit screw clamp terminals 2 1.5-6 mm² flexible without cable end || control circuit without connection
Net Weight 0.865 kg
Fixing Mode clipped DIN rail) || screw-fixed plate)
[Uimp] Rated Impulse Withstand Voltage 6 kVIEC 60947-6-2
Standards EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
[Ui] Rated Insulation Voltage 690 V IEC 60947-6-2 3) || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Typical Current Consumption 200 mA 24 V DC I maximum while closing with LUCM || 220 mA 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 220 mA 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 25 mA 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD || 25 mA 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD || 280 mA 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 280 mA 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 280 mA 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 280 mA 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD || 45 mA 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD || 45 mA 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD || 75 mA 24 V DC I rms sealed with LUCM || 80 mA 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD || 90 mA 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
Mechanical Durability 15 Mcycles
Compatibility Code LUB
Operating Time 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit || 50 ms >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit || 60 ms 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit || 70 ms 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit || 65 ms closing with LUCM control circuit
Width 45 mm
Tightening Torque control circuit 0.8-1.2 N.m flat 5 mm || control circuit 0.8-1.2 N.m Philips no 1 5 mm || power circuit 1.9-2.5 N.m flat 6 mm || power circuit 1.9-2.5 N.m Philips No 2 6 mm || power circuit 1.9-2.5 N.m pozidriv No 2 6 mm
Safe Separation Of Circuit 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
Depth 126 mm
Heat Dissipation 3-3 W control circuit with LUCA, LUCB, LUCC, LUCD || 1.8-1.8 W control circuit with LUCM
[Ics] Rated Service Breaking Capacity 50 kA 230 V || 50 kA 440 V || 10 kA 500 V || 4 kA 690 V
[Ue] Rated Operational Voltage 690 V AC power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Uc] Control Circuit Voltage 24 V AC 50/60 Hz || 24 V DC || 48...72 V AC 50/60 Hz || 48...72 V DC || 110...240 V AC 50/60 Hz || 110...220 V DC
Product Or Component Type non reversing power base
[Ith] Conventional Free Air Thermal Current 32 A
Product Name TeSys Ultra
Range TeSys
Utilisation Category AC-43 || AC-44 || AC-41
[Ie] Rated Operational Current 28.5 A <= 440 V || 23 A 500 V || 21 A 690 V
Suitability For Isolation yes
Auxiliary Contacts Type linked contacts 1 NO + 1 NC) IEC 60947-4-1 || mirror contact 1 NC) IEC 60947-1
Poles Description 3P
Network Frequency 40...60 Hz
Device Application motor control || motor protection
Device Short Name LUB
Read more arrow Read less arrow
*New items come with up to 24 month Obso Warranty
Our previously used items and repair options come with 12 months Obso Warranty.


"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
*Same & Next Day Delivery & Collection is available for stock from our UK and NL branches. Next-day delivery collection and 2 day delivery is available for stock sourced from our partners. In 90% of cases, we can deliver faster than the manufacturer’s ETA where required.

Standard options for delivery are also available where required.


"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
We are ISO 9001 accredited so you have peace of mind with your purchase.

What our customers say about us

Trustpilot

1

Step 1

    Part added for enquiry

    2

    Step 2

    Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.

    3

    Step 3

    We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.

    4

    Step 4

    Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.