LC1F115
Contactor body,TeSys F,3P(3NO), AC-3, <=440V 115A, without coil
AVAILABLE
GET A QUOTE NOW
| Specification | Value |
|---|---|
| Product Certifications | RINA || ABS || CSA || DNV || RMRoS || BV || LROS (Lloyds register of shipping) || UL || CB || UKCA |
| Power Dissipation Per Pole | 15 W AC-1 || 5 W AC-3 |
| Average Impedance | 0.37 mOhm - Ith 200 A 50 Hz |
| Control Circuit Voltage Limits | operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil || drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil || operational: 0.85...1.1 Uc DC with LX4 coil || drop-out: 0.15...0.2 Uc DC with LX4 coil || operational: 85...275 V AC 50/60 Hz with LXE coil || drop-out: 0...60 V AC 50/60 Hz with LXE coil || operational: 85...418 V DC with LXE coil || drop-out: 0...45 V DC with LXE coil |
| [Ith] Conventional Free Air Thermal Current | 200 A (at 40 °C) |
| Standards | EN 60947-1 || JIS C8201-4-1 || IEC 60947-4-1 || EN 60947-4-1 || IEC 60947-1 |
| [Uc] Control Circuit Voltage | 24...575 V AC 40...400 Hz with LX9 coil || 24...460 V DC with LX4 coil || 100...250 V AC 50/60 Hz with LXE coil || 100...380 V DC with LXE coil |
| Mounting Support | plate |
| Rated Breaking Capacity | 920 A conforming to IEC 60947-4-1 |
| Irms Rated Making Capacity | 1150 A conforming to IEC 60947-4-1 |
| Associated Fuse Rating | 125 A aM at <= 440 V || 200 A gG at <= 440 V |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
| Connections - Terminals | power circuit lugs-ring terminals 1 95-95 mm² || power circuit connector 1 95-95 mm² || power circuit bar 2 20 x 3 mm || power circuit bolted connection || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm² || control circuit screw clamp terminals 2 1-4 mm² || control circuit screw clamp terminals 1.0 0.2-2.5 mm²flexible without cable end || control circuit screw clamp terminals 1.0 0.25-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1.0 0.2-2.5 mm²solid without cable end |
| Inrush Power In Va | 590-855 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil || 543-665 VA (at 20 °C)with LX4 coil || 280-310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil || 270-320 VA (at 20 °C)with LXE coil |
| Maximum Operating Rate | 2400 cyc/h 55 °C |
| Operating Time | 35 ms closing with LX9 coil || 130 ms opening with LX9 coil || 30...40 ms closing with LX4 coil || 30...50 ms opening with LX4 coil || 40...80 ms closing with LXE coil || 6...54 ms opening with LXE coil |
| Tightening Torque | power circuit 10 N.m || control circuit 1.2 N.m || control circuit 0.6 N.m |
| Mechanical Durability | 10 Mcycles |
| Compatibility Code | LC1F |
| Hold-In Power Consumption In Va | 6.6-8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil || 3.94-4.83 VA (at 20 °C)with LX4 coil || 4.5-7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil || 2.5-4.0 VA (at 20 °C)with LXE coil |
| Overvoltage Category | III |
| [Ui] Rated Insulation Voltage | 1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C |
| [Icw] Rated Short-Time Withstand Current | 1100 A 40 °C - 10 s || 640 A 40 °C - 30 s || 520 A 40 °C - 1 min || 400 A 40 °C - 3 min || 320 A 40 °C - 10 min |
| Heat Dissipation | 5.9-7.2 W || 2.2-5.5 W |
| [Ue] Rated Operational Voltage | <= 690 V AC 50/60 Hz || <= 460 V DC |
| Contactor Application | resistive load || motor control |
| Product Or Component Type | contactor |
| Product Name | TeSys F |
| Range | TeSys |
| Pole Contact Composition | 3 NO |
| [Ie] Rated Operational Current | 200 A 40 °C) <= 440 V AC-1 || 115 A 55 °C) <= 440 V AC-3 |
| Utilisation Category | AC-1 || AC-4 || AC-3 |
| Poles Description | 3P |
| Motor Power Kw | 55 kW at 380...400 V AC 50/60 Hz (AC-3) || 59 kW at 415 V AC 50/60 Hz (AC-3) || 59 kW at 440 V AC 50/60 Hz (AC-3) || 75 kW at 500 V AC 50/60 Hz (AC-3) || 30 kW at 220...240 V AC 50/60 Hz (AC-3) || 80 kW at 660...690 V AC 50/60 Hz (AC-3) || 18.5 kW at 400 V AC 50/60 Hz (AC-4) |
| Device Short Name | LC1F |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews