EMS59201

Schneider Electric

PowerLogic SC150 CT-LPVT/VT: Switch controller, 1/5 A, LPVT/VT sensors

AVAILABLE

GET A QUOTE NOW

  • "The Easergy SC150 module offers many high-performance features needed to measure and detect a fault current on the MV line. The switch controller are designed for clip in DIN rail. The measurement voltage range from 0\u202610 VAC LPVT and from 47\u2026240 VAC VTs. It include 8 digital inputs, 2 digital relay switch, and 2 RJ45 communication port. The operating temperature is -40\u00b0C to + 70\u00b0C. The storage temperature is -40\u00b0C to + 85\u00b0C. Mechanical dimensions are 140 mm in height, 45 mm in width and 140 mm in depth."
Read more arrow Read less arrow
Specification Value
Range Of Product PowerLogic T300
Device Short Name SC150
Communication Port Support 2 ETHERNET RJ45
Measurement Voltage : 0-10 V LPVT AC at 50/60 Hz (single or three phases) || : 47-240 V VTs AC at 50/60 Hz (single or three phases)
Number Of Outputs 2 digital (relay) switch:
Continuous Output Current 8 A
Memory Capacity 4 MB
Output Voltage 12...127 V DC motor: || 90...220 V AC motor:
Protection Type ANSI 50/51 : overcurrent || ANSI 50N/51N : earth fault || ANSI 67 : directional phase overcurrent || ANSI 67N : directional earth fault || ANSI 47 : negative sequence overvoltage || ANSI 27 : undervoltage || ANSI 59 : overvoltage || ANSI 59N : neutral voltage displacement || ANSI 37 : phase undercurrent
Type Of Measurement apparent power || voltage || active and reactive power || active and reactive energy || power factor || current || frequency || apparent energy
Product Or Component Type MV switch controller
Irms Rated Making Capacity 15 A 4 s
Measurement Current 5-5 A || 1-1 A
Maximum Switching Voltage 440 V AC
Number Of Inputs 8 digital IEC 61131-2 type 3
[Us] Rated Supply Voltage 12...48 V DC +/- 20 %
Communication Port Protocol IEC 60870-5-104
Power Consumption In Va 2 VA
Software Function assistance in commissioning and operating the installation || security/authority verification || alarm || event log || Operating/Status report || reports and diagrams
Control Type illuminated push-button status:
Data Recording sag and swell logs || harmonics logs || min/max of instantaneous values || demand values || event logs || sequence of event recording || counter || current value before fault
Breaking Capacity 2000 VA
Analogue Input Type current 0.01...35 A (impedance 0.001 Ohm)4 x
Type Of Measurement current class 0.5 || voltage class 0.5 || energy class 1 IEC 61557-12
Synchronisation Time Between Inputs 1 ms
Power Quality Analysis voltage unbalance || individual harmonics || voltage sag and swell detection || harmonic distortion || voltage magnitude
Read more arrow Read less arrow
*New items come with up to 24 month Obso Warranty
Our previously used items and repair options come with 12 months Obso Warranty.


"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
*Same & Next Day Delivery & Collection is available for stock from our UK and NL branches. Next-day delivery collection and 2 day delivery is available for stock sourced from our partners. In 90% of cases, we can deliver faster than the manufacturer’s ETA where required.

Standard options for delivery are also available where required.


"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
We are ISO 9001 accredited so you have peace of mind with your purchase.

What our customers say about us

Trustpilot

1

Step 1

    Part added for enquiry

    2

    Step 2

    Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.

    3

    Step 3

    We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.

    4

    Step 4

    Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.