EMS59201
Schneider Electric
PowerLogic SC150 CT-LPVT/VT: Switch controller, 1/5 A, LPVT/VT sensors
Disponible
Obtenez un devis maintenant
- "The Easergy SC150 module offers many high-performance features needed to measure and detect a fault current on the MV line. The switch controller are designed for clip in DIN rail. The measurement voltage range from 0\u202610 VAC LPVT and from 47\u2026240 VAC VTs. It include 8 digital inputs, 2 digital relay switch, and 2 RJ45 communication port. The operating temperature is -40\u00b0C to + 70\u00b0C. The storage temperature is -40\u00b0C to + 85\u00b0C. Mechanical dimensions are 140 mm in height, 45 mm in width and 140 mm in depth."
| Specification | Value |
|---|---|
| Range Of Product | PowerLogic T300 |
| Device Short Name | SC150 |
| Communication Port Support | 2 ETHERNET RJ45 |
| Measurement Voltage | : 0-10 V LPVT AC at 50/60 Hz (single or three phases) || : 47-240 V VTs AC at 50/60 Hz (single or three phases) |
| Number Of Outputs | 2 digital (relay) switch: |
| Continuous Output Current | 8 A |
| Memory Capacity | 4 MB |
| Output Voltage | 12...127 V DC motor: || 90...220 V AC motor: |
| Protection Type | ANSI 50/51 : overcurrent || ANSI 50N/51N : earth fault || ANSI 67 : directional phase overcurrent || ANSI 67N : directional earth fault || ANSI 47 : negative sequence overvoltage || ANSI 27 : undervoltage || ANSI 59 : overvoltage || ANSI 59N : neutral voltage displacement || ANSI 37 : phase undercurrent |
| Type Of Measurement | apparent power || voltage || active and reactive power || active and reactive energy || power factor || current || frequency || apparent energy |
| Product Or Component Type | MV switch controller |
| Irms Rated Making Capacity | 15 A 4 s |
| Measurement Current | 5-5 A || 1-1 A |
| Maximum Switching Voltage | 440 V AC |
| Number Of Inputs | 8 digital IEC 61131-2 type 3 |
| [Us] Rated Supply Voltage | 12...48 V DC +/- 20 % |
| Communication Port Protocol | IEC 60870-5-104 |
| Power Consumption In Va | 2 VA |
| Software Function | assistance in commissioning and operating the installation || security/authority verification || alarm || event log || Operating/Status report || reports and diagrams |
| Control Type | illuminated push-button status: |
| Data Recording | sag and swell logs || harmonics logs || min/max of instantaneous values || demand values || event logs || sequence of event recording || counter || current value before fault |
| Breaking Capacity | 2000 VA |
| Analogue Input Type | current 0.01...35 A (impedance 0.001 Ohm)4 x |
| Type Of Measurement | current class 0.5 || voltage class 0.5 || energy class 1 IEC 61557-12 |
| Synchronisation Time Between Inputs | 1 ms |
| Power Quality Analysis | voltage unbalance || individual harmonics || voltage sag and swell detection || harmonic distortion || voltage magnitude |
Nos articles d'occasion et nos options de réparation sont assortis d'une garantie Obso de 12 mois.
"Super service ! Tout a été traité très rapidement et avec compétence et l'assistance personnelle était excellente. Je choisirai toujours Obso Automation ! Merci beaucoup pour votre soutien." - MJ
Des options de livraison standard sont également disponibles si nécessaire.
"Professionnel, courtois et précis. La pièce obsolète a fait l'objet d'un devis le jour même et a été livrée le lendemain" - PT
1
Step 1
Partie ajoutée pour enquête
2
Étape 2
Votre gestionnaire de compte personnel est déjà sur le coup et vous fournit des réponses rapides avec un service imbattable.
3
Étape 3
Nous ne nous contentons pas de traiter les commandes, nous garantissons une livraison sans heurts, une transparence totale et une absence totale de maux de tête.
4
Étape 4
Plus de 10 000 clients nous font confiance pour une bonne raison. Obtenez votre devis dès maintenant et découvrez l’automatisation sans risque, ni délai, ni incertitude.
Google Reviews