LV432075
trip unit MicroLogic 6.3 E-M for ComPact NSX 400/630 circuit breakers, electronic, rating 320 A, 3 poles 3d
Disponibile
Richiedi un preventivo adesso
| Specification | Value |
|---|---|
| [Tg] Ground-Fault Time Delay Adjustment Range | 0-0.4 s |
| [Ig] Ground-Fault Pick-Up Adjustment Range | 0.2...1 x In In > 50 A || 0.3...1 x In In = 50 A || 0.6...1 x In In = 25 A || Ig enable on/off |
| Thermal Memory | 20 minutes before and after tripping |
| Earth-Leakage Protection | without |
| Ground-Fault Time Delay Adjustment Type -Tg | adjustable |
| Complementary Motor Protection | protracted starting time || current unbalance || underload || stalled rotor |
| Ground-Fault Pick-Up Adjustment Type | adjustable |
| Type Of Measurement | energy meter |
| Long Time Delay Adjustment Type | adjustable |
| Instantaneous Pick-Up Adjustment Type Ii | fixed |
| Zone Selective Interlocking Zsi | with |
| Electrical Data Recording | maintenance indicators |
| [Tr] Long-Time Delay Adjustment Range | 120-120 s 1.5 x Ir 5 || 6.5-6.5 s 6 x Ir 5 || 5-5 s 7.2 x Ir 5 || 240-240 s 1.5 x Ir 10 || 13.5-13.5 s 6 x Ir 10 || 10-10 s 7.2 x Ir 10 || 480-480 s 1.5 x Ir 20 || 26-26 s 6 x Ir 20 || 20-20 s 7.2 x Ir 20 || 720-720 s 1.5 x Ir 30 || 38-38 s 6 x Ir 30 || 30-30 s 7.2 x Ir 30 |
| Short-Time Delay Adjustment Type | fixed |
| Instantaneous Pick-Up Adjustment Range | 4800 A |
| Long Time Pick-Up Adjustment Type Ir | adjustable 9 settings |
| Long Time Pick-Up Adjustment Range | 160...320 A |
| [Tsd] Short-Time Delay Adjustment Range | 0.01-0.01 s |
| Motor Tripping Class | 30 || 10 || 20 || 5 |
| [Isd] Short-Time Pick-Up Adjustment Range | 5...13 x Ir |
| Display Type | LCD display |
| Short-Time Pick-Up Adjustment Type Isd | adjustable 9 settings |
| Network Frequency | 50/60 Hz |
| Trip Unit Name | MicroLogic 6.3 E-M |
| Range Of Product | ComPact NSX400...630 |
| [Ue] Rated Operational Voltage | 690 V AC 50/60 Hz |
| Trip Unit Protection Functions | LSIG |
| Network Type | AC |
| Protected Poles Description | 3t |
| Product Or Component Type | trip unit |
| Protection Type | L : for overload protection (long time) || S : for short time short-circuit protection || I : for instantaneous short-circuit protection || G : for ground fault protection |
| Range | ComPact |
| Poles Description | 3P |
| Range Compatibility | ComPact NSX400 || ComPact NSX630 |
| Device Application | motor |
| Trip Unit Technology | electronic |
I nostri articoli usati in precedenza e le opzioni di riparazione sono coperti da 12 mesi di garanzia Obso.
“Servizio super! Tutto è stato elaborato in modo molto rapido e competente e il supporto personale è stato eccellente. Sceglierei sempre di nuovo Obso Automation! Molte grazie per l'ottimo supporto”. - MJ
Se necessario, sono disponibili anche opzioni standard per la consegna.
“Professionale, cortese e preciso. Pezzo obsoleto quotato il giorno stesso e fornito il giorno successivo” - PT
1
Step 1
Parte aggiunta per richiesta
2
Passo 2
Il vostro Account Manager personale è già al lavoro, fornendo risposte rapide e un servizio imbattibile.
3
Passo 3
Non ci limitiamo a elaborare gli ordini, ma garantiamo una consegna senza intoppi, piena trasparenza e zero grattacapi.
4
Passo 4
Più di 10.000 clienti si fidano di noi per un motivo. Richiedete subito il vostro preventivo e sperimentate l’automazione senza rischi, ritardi o incertezze.
Google Reviews