LU6MB0FU
Schneider Electric
Reverser block for side mounting, TeSys Ultra, 38A/690V, coil 110-240VAC/DC
Disponibile
Richiedi un preventivo adesso
- "TeSys U reversing module for side mounting, for the constitution of TeSys U reversing starter controllers. It provides reverse power contacts, coil control with interlocking capabilities to be supplied with 110-240V AC / 110-220V DC. To be used with an advanced power base LUB120, LUB320, or LUB380 equipped with a Control Unit LUC*FU type. To be associated with an assembling connector LU9MR1 and a control terminal block LU9M1 to complete the side mounting. Green Premium compliant (RoHS/REACh)."
| Specification | Value |
|---|---|
| Product Certifications | CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine |
| [Ue] Rated Operational Voltage | 690 V AC power circuit |
| Height | 115 mm |
| Connections - Terminals | control circuit screw clamp terminals 1 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) rigid || control circuit screw clamp terminals 2 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) rigid || power circuit screw clamp terminals 1 1-10 mm² 4 mm) rigid || power circuit screw clamp terminals 1 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² 4 mm) flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) rigid || power circuit screw clamp terminals 2 1.5-6 mm² 4 mm) flexible without cable end |
| Net Weight | 0.425 kg |
| Fixing Mode | clipped DIN rail) || screw-fixed plate) |
| [Uimp] Rated Impulse Withstand Voltage | 6 kVIEC 60947-6-2 |
| Inrush Restraint Duration | 25 ms AC || 15 ms DC |
| Standards | EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier |
| [Ui] Rated Insulation Voltage | 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1 |
| Compatibility Code | LU6MB |
| Operating Time | 150 ms with change of direction || 75 ms without change of direction |
| Width | 45 mm |
| Tightening Torque | control circuit 0.8-1.2 N.m flat 5 mm || control circuit 0.8-1.2 N.m Philips No 2 5 mm || power circuit 1.9-2.5 N.m flat 6 mm || power circuit 1.9-2.5 N.m Philips No 2 6 mm || power circuit 1.9-2.5 N.m pozidriv No 2 6 mm |
| Depth | 113 mm |
| Network Frequency | 40...60 Hz |
| Device Mounting | separate mounting |
| [Uc] Control Circuit Voltage | 110...240 V AC 50/60 Hz || 110...220 V DC |
| Product Or Component Type | reverser block |
| Current Consumption | 1000 mA 110...220 V DC I maximum while closing || 1000 mA 110...240 V AC I maximum while closing |
| Range | TeSys |
| [Ie] Rated Operational Current | 38 A |
| Device Application | motor control |
| Device Short Name | LU6MB |
I nostri articoli usati in precedenza e le opzioni di riparazione sono coperti da 12 mesi di garanzia Obso.
“Servizio super! Tutto è stato elaborato in modo molto rapido e competente e il supporto personale è stato eccellente. Sceglierei sempre di nuovo Obso Automation! Molte grazie per l'ottimo supporto”. - MJ
Se necessario, sono disponibili anche opzioni standard per la consegna.
“Professionale, cortese e preciso. Pezzo obsoleto quotato il giorno stesso e fornito il giorno successivo” - PT
1
Step 1
Parte aggiunta per richiesta
2
Passo 2
Il vostro Account Manager personale è già al lavoro, fornendo risposte rapide e un servizio imbattibile.
3
Passo 3
Non ci limitiamo a elaborare gli ordini, ma garantiamo una consegna senza intoppi, piena trasparenza e zero grattacapi.
4
Passo 4
Più di 10.000 clienti si fidano di noi per un motivo. Richiedete subito il vostro preventivo e sperimentate l’automazione senza rischi, ritardi o incertezze.
Google Reviews