- "TeSys U reversing module for vertical mounting, for the constitution of TeSys U reversing starter controllers. It provides reverse power contacts, coil control with interlocking capabilities to be supplied with 24V AC. To be used with an advanced power base LUB120 or LUB320 equipped with a Control Unit LUC*B type. To be associated with an assembling connector LU9MR1C and a control terminal block LU9M1 to complete the vertical mounting. Green Premium compliant (RoHS/REACh)."
| Specification | Value |
|---|---|
| Product Certifications | CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine |
| [Ue] Rated Operational Voltage | 690 V AC power circuit |
| Height | 80 mm |
| Connections - Terminals | control circuit screw clamp terminals 1 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) rigid || control circuit screw clamp terminals 2 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) rigid || power circuit screw clamp terminals 1 1-10 mm² 4 mm) rigid || power circuit screw clamp terminals 1 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² 4 mm) flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) rigid || power circuit screw clamp terminals 2 1.5-6 mm² 4 mm) flexible without cable end |
| Net Weight | 0.4 kg |
| Fixing Mode | plug-in |
| [Uimp] Rated Impulse Withstand Voltage | 6 kVIEC 60947-6-2 |
| Inrush Restraint Duration | 25 ms AC || 15 ms DC |
| Standards | EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier |
| [Ui] Rated Insulation Voltage | 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1 |
| Compatibility Code | LU2MB |
| Operating Time | 150 ms with change of direction || 75 ms without change of direction |
| Width | 45 mm |
| Tightening Torque | control circuit 0.8-1.2 N.m flat 5 mm || control circuit 0.8-1.2 N.m Philips No 2 5 mm || power circuit 1.9-2.5 N.m flat 6 mm || power circuit 1.9-2.5 N.m Philips No 2 6 mm |
| Depth | 105 mm |
| Network Frequency | 40...60 Hz |
| Device Mounting | direct mounting |
| [Uc] Control Circuit Voltage | 24 V AC 50/60 Hz |
| Product Or Component Type | reverser block |
| Current Consumption | 2360 mA 24 V AC I maximum while closing |
| Range | TeSys |
| [Ie] Rated Operational Current | 32 A |
| Device Application | motor control |
| Device Short Name | LU2MB |
I nostri articoli usati in precedenza e le opzioni di riparazione sono coperti da 12 mesi di garanzia Obso.
“Servizio super! Tutto è stato elaborato in modo molto rapido e competente e il supporto personale è stato eccellente. Sceglierei sempre di nuovo Obso Automation! Molte grazie per l'ottimo supporto”. - MJ
Se necessario, sono disponibili anche opzioni standard per la consegna.
“Professionale, cortese e preciso. Pezzo obsoleto quotato il giorno stesso e fornito il giorno successivo” - PT
1
Step 1
Parte aggiunta per richiesta
2
Passo 2
Il vostro Account Manager personale è già al lavoro, fornendo risposte rapide e un servizio imbattibile.
3
Passo 3
Non ci limitiamo a elaborare gli ordini, ma garantiamo una consegna senza intoppi, piena trasparenza e zero grattacapi.
4
Passo 4
Più di 10.000 clienti si fidano di noi per un motivo. Richiedete subito il vostro preventivo e sperimentate l’automazione senza rischi, ritardi o incertezze.
Google Reviews