LC1F265X7
Schneider Electric
contactor, TeSys F, 3P(3NO), AC-3, <=440V 265 A, coil 550...600V AC
Disponibile
Richiedi un preventivo adesso
-
| Specification | Value |
|---|---|
| Product Certifications | CCC || RINA || CB || BV || RMRoS || UL || DNV || LROS (Lloyds register of shipping) || ABS || UKCA |
| Power Dissipation Per Pole | 37 W AC-1 || 21 W AC-3 |
| Average Impedance | 0.3 mOhm - Ith 350 A 50 Hz |
| [Ith] Conventional Free Air Thermal Current | 350 A (at 40 °C) |
| Control Circuit Voltage Limits | operational 0.85...1.1 Uc 40...400 Hz 55 °C) || drop-out 0.15...0.2 Uc 40...400 Hz 55 °C) |
| Standards | EN 60947-1 || IEC 60947-1 || JIS C8201-4-1 || IEC 60947-4-1 || EN 60947-4-1 |
| Mounting Support | plate |
| Control Circuit Type | AC 40...400 Hz |
| Rated Breaking Capacity | 2120 A conforming to IEC 60947-4-1 |
| Associated Fuse Rating | 315 A aM at <= 440 V || 400 A gG at <= 440 V |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
| Inrush Power In Va | 650-650 VA, 40...400 Hz 0.9 20 °C) |
| Connections - Terminals | control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit bar 2 32 x 4 mm || power circuit lugs-ring terminals 1 240-240 mm² || power circuit connector 1 240-240 mm² || power circuit bolted connection |
| Pole Contact Composition | 3 NO |
| Operating Time | 40...65 ms closing || 100...170 ms opening |
| Maximum Operating Rate | 2400 cyc/h 55 °C |
| Mechanical Durability | 10 Mcycles |
| Tightening Torque | control circuit 1.2 N.m || power circuit 35 N.m |
| Compatibility Code | LC1F |
| Hold-In Power Consumption In Va | 10-10 VA, 40...400 Hz 0.9 20 °C) |
| Overvoltage Category | III |
| Motor Power Kw | 132 kW at 380...400 V AC 50/60 Hz (AC-3) || 140 kW at 415 V AC 50/60 Hz (AC-3) || 140 kW at 440 V AC 50/60 Hz (AC-3) || 160 kW at 500 V AC 50/60 Hz (AC-3) || 160 kW at 660...690 V AC 50/60 Hz (AC-3) || 147 kW at 1000 V AC 50/60 Hz (AC-3) || 75 kW at 220...230 V AC 50/60 Hz (AC-3) || 51 kW at 400 V AC 50/60 Hz (AC-4) |
| [Ui] Rated Insulation Voltage | 1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C |
| [Icw] Rated Short-Time Withstand Current | 2200 A 40 °C - 10 s || 1230 A 40 °C - 30 s || 950 A 40 °C - 1 min || 620 A 40 °C - 3 min || 480 A 40 °C - 10 min |
| Heat Dissipation | 8-8 W |
| [Uc] Control Circuit Voltage | 550...600 V AC 40...400 Hz |
| Range Of Product | TeSys F |
| [Ue] Rated Operational Voltage | <= 1000 V AC-1 || <= 690 V AC-3 || <= 690 V AC-4 || <= 460 V DC |
| Contactor Application | motor control || resistive load |
| Product Or Component Type | contactor |
| Range | TeSys |
| Utilisation Category | AC-4 || AC-1 || AC-3 |
| [Ie] Rated Operational Current | 350 A (at <40 °C) at <= 440 V AC AC-1 || 265 A (at <55 °C) at <= 440 V AC AC-3 |
| Poles Description | 3P |
| Device Short Name | LC1F |
I nostri articoli usati in precedenza e le opzioni di riparazione sono coperti da 12 mesi di garanzia Obso.
“Servizio super! Tutto è stato elaborato in modo molto rapido e competente e il supporto personale è stato eccellente. Sceglierei sempre di nuovo Obso Automation! Molte grazie per l'ottimo supporto”. - MJ
Se necessario, sono disponibili anche opzioni standard per la consegna.
“Professionale, cortese e preciso. Pezzo obsoleto quotato il giorno stesso e fornito il giorno successivo” - PT
1
Step 1
Parte aggiunta per richiesta
2
Passo 2
Il vostro Account Manager personale è già al lavoro, fornendo risposte rapide e un servizio imbattibile.
3
Passo 3
Non ci limitiamo a elaborare gli ordini, ma garantiamo una consegna senza intoppi, piena trasparenza e zero grattacapi.
4
Passo 4
Più di 10.000 clienti si fidano di noi per un motivo. Richiedete subito il vostro preventivo e sperimentate l’automazione senza rischi, ritardi o incertezze.
Google Reviews