LC1F1400
Schneider Electric
contactor body withou coil, TeSys F, 3P(3NO), AC-1, <=1000V AC 1400A, with coil LX1/ LX9, 110…500V AC 40/400Hz, LX4, 110...440V DC
Disponibile
Richiedi un preventivo adesso
-
| Specification | Value |
|---|---|
| Product Certifications | CSA || EAC || CB Scheme || CCC || UL || UKCA |
| Power Dissipation Per Pole | 150 W AC-1 |
| Average Impedance | 0.1 mOhm - Ith 1400 A 50 Hz |
| Control Circuit Voltage Limits | operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil || drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil || operational: 0.85...1.1 Uc DC with LX4 coil || drop-out: 0.2...0.35 Uc DC with LX4 coil |
| [Ith] Conventional Free Air Thermal Current | 1400 A (at 40 °C) |
| Standards | EN 60947-4-1 || IEC 60947-1 || JIS C8201-4-1 || IEC 60947-4-1 || EN 60947-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 |
| [Uc] Control Circuit Voltage | 100...500 V AC 40...400 Hz with LX1/LX9 coil || 110...440 V DC with LX4 coil |
| Mounting Support | plate |
| Rated Breaking Capacity | 2100 A conforming to IEC 60947-4-1 |
| Irms Rated Making Capacity | 2100 A AC conforming to IEC 60947-4-1 |
| Associated Fuse Rating | 1600 A gG at <= 440 V conforming to IEC 60947-4-1 |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
| Inrush Power In Va | 1600-2400 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 2000-2200 VA (at 20 °C)with LX4 coil |
| Connections - Terminals | power circuit bar 2 || power circuit bolted connection || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm² |
| Maximum Operating Rate | 600 cyc/h 55 °C |
| Operating Time | 40...50 ms closing with LX1/LX9 coil || 100...170 ms opening with LX1/LX9 coil || 50...60 ms closing with LX4 coil || 40...50 ms opening with LX4 coil |
| Tightening Torque | power circuit 58 N.m || control circuit 1.2 N.m |
| Mechanical Durability | 0.5 Mcycles |
| Hold-In Power Consumption In Va | 29-37 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 8-10 VA (at 20 °C)with LX4 coil |
| Overvoltage Category | III |
| [Ui] Rated Insulation Voltage | 1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C || 1000 V UL 60947-4-1 |
| [Icw] Rated Short-Time Withstand Current | 8000 A 40 °C - 10 s || 6000 A 40 °C - 30 s || 4500 A 40 °C - 1 min || 4000 A 40 °C - 3 min || 2600 A 40 °C - 10 min |
| Heat Dissipation | 18-18 W |
| [Ue] Rated Operational Voltage | <= 1000 V AC 50/60 Hz || <= 460 V DC |
| Contactor Application | resistive load |
| Product Or Component Type | contactor |
| Product Name | TeSys F |
| Range | TeSys |
| Pole Contact Composition | 3 NO |
| [Ie] Rated Operational Current | 1400 A 40 °C) <= 440 V AC AC-1 |
| Utilisation Category | AC-1 |
| Poles Description | 3P |
| Device Short Name | LC1F |
I nostri articoli usati in precedenza e le opzioni di riparazione sono coperti da 12 mesi di garanzia Obso.
“Servizio super! Tutto è stato elaborato in modo molto rapido e competente e il supporto personale è stato eccellente. Sceglierei sempre di nuovo Obso Automation! Molte grazie per l'ottimo supporto”. - MJ
Se necessario, sono disponibili anche opzioni standard per la consegna.
“Professionale, cortese e preciso. Pezzo obsoleto quotato il giorno stesso e fornito il giorno successivo” - PT
1
Step 1
Parte aggiunta per richiesta
2
Passo 2
Il vostro Account Manager personale è già al lavoro, fornendo risposte rapide e un servizio imbattibile.
3
Passo 3
Non ci limitiamo a elaborare gli ordini, ma garantiamo una consegna senza intoppi, piena trasparenza e zero grattacapi.
4
Passo 4
Più di 10.000 clienti si fidano di noi per un motivo. Richiedete subito il vostro preventivo e sperimentate l’automazione senza rischi, ritardi o incertezze.
Google Reviews