GV2RT06
TeSys GV2 Manual Starter and Protector, thermal magnetic circuit protector, toggle switch, 1…1.6 A, screw clamp terminals
Disponibile
Richiedi un preventivo adesso
| Specification | Value |
|---|---|
| Line Rated Current | 1.6 A |
| [Ue] Rated Operational Voltage | 690 V AC 50/60 Hz IEC 60947-2 |
| Height | 89 mm |
| Rated Duty | continuous IEC 60947-4-1 |
| Network Type | AC |
| Magnetic Tripping Current | 33-33 A |
| [Ith] Conventional Free Air Thermal Current | 1.6 A IEC 60947-4-1 |
| Motor Power Kw | 0.18-0.18 kW 220/230 V AC 50/60 Hz motor protection high peak current || 0.25-0.25 kW 220/230 V AC 50/60 Hz motor protection high peak current || 0.37-0.37 kW 400/415 V AC 50/60 Hz motor protection high peak current || 0.55-0.55 kW 400/415 V AC 50/60 Hz motor protection high peak current || 0.37-0.37 kW 440 V AC 50/60 Hz motor protection high peak current || 0.55-0.55 kW 440 V AC 50/60 Hz motor protection high peak current || 0.37-0.37 kW 500 V AC 50/60 Hz motor protection high peak current || 0.55-0.55 kW 500 V AC 50/60 Hz motor protection high peak current || 0.75-0.75 kW 500 V AC 50/60 Hz motor protection high peak current || 0.75-0.75 kW 690 V AC 50/60 Hz motor protection high peak current || 1.1-1.1 kW 690 V AC 50/60 Hz motor protection high peak current || 0.4-0.4 kW 230/240 V AC 50/60 Hz transformer protection || 0.63-0.63 kW 400/415 V AC 50/60 Hz transformer protection |
| Utilisation Category | category A IEC 60947-2 || AC-3 IEC 60947-4-1 |
| Fixing Mode | 35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate) |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-2 |
| Control Type | toggle |
| Power Dissipation Per Pole | 2.5 W |
| Electrical Durability | 100000 cycles AC-3 415 V In |
| [Ui] Rated Insulation Voltage | 690 V AC 50/60 Hz IEC 60947-2 |
| Breaking Capacity | 100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2 |
| Suitability For Isolation | yes IEC 60947-1 § 7-1-6 |
| Thermal Protection Adjustment Range | 1-1.6 A IEC 60947-4-1 |
| Tightening Torque | 1.7 N.m screw clamp terminal |
| Mechanical Durability | 100000 cycles |
| Poles Description | 3P |
| Width | 45 mm |
| Depth | 78.5 mm |
| Network Frequency | 50/60 Hz IEC 60947-4-1 |
| Product Or Component Type | motor circuit breaker |
| Product Name | TeSys GV2 || TeSys Deca |
| Range | TeSys Deca |
| Device Application | motor protection || motor |
| Device Short Name | GV2RT |
| Trip Unit Technology | thermal-magnetic |
I nostri articoli usati in precedenza e le opzioni di riparazione sono coperti da 12 mesi di garanzia Obso.
“Servizio super! Tutto è stato elaborato in modo molto rapido e competente e il supporto personale è stato eccellente. Sceglierei sempre di nuovo Obso Automation! Molte grazie per l'ottimo supporto”. - MJ
Se necessario, sono disponibili anche opzioni standard per la consegna.
“Professionale, cortese e preciso. Pezzo obsoleto quotato il giorno stesso e fornito il giorno successivo” - PT
1
Step 1
Parte aggiunta per richiesta
2
Passo 2
Il vostro Account Manager personale è già al lavoro, fornendo risposte rapide e un servizio imbattibile.
3
Passo 3
Non ci limitiamo a elaborare gli ordini, ma garantiamo una consegna senza intoppi, piena trasparenza e zero grattacapi.
4
Passo 4
Più di 10.000 clienti si fidano di noi per un motivo. Richiedete subito il vostro preventivo e sperimentate l’automazione senza rischi, ritardi o incertezze.
Google Reviews