BCPMSCE1S
Schneider Electric
2 adapter boards - advanced + ethernet - full power and energy on all circuits
Disponibile
Richiedi un preventivo adesso
- "This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for retrofit and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (including 50A, 100A or 200A split-core current transformers) on all branch channels. The BCPM allow the monitoring of both the branch circuits and mains values, incoming power and energy for a maximum of 42 circuits. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with serial connection for either Modbus RTU or BACnet MS/TP, and an Ethernet connection for Modbus TCP, BACnet IP and SNMP. The meter need to be powered by a 100V AC to 277V AC supply source. This version is for 42 circuits, but do not include branch current transformers nor ribbon. The device dimensions are 353mm in width, 253mm in height, 71mm in depth and weight 1.5 kilograms."
| Specification | Value |
|---|---|
| Network Frequency | 50 Hz || 60 Hz |
| Power Quality Analysis | voltage sag and swell detection |
| Variant | advanced + ethernet |
| Type Of Measurement | voltage || current || frequency || active power || power factor || active energy |
| Power Monitoring | basic instrumentation |
| Product Or Component Type | multi-circuit energy meter |
| Product Name | PowerLogic BCPMSC |
| Range | PowerLogic |
| Energy Management | sub billing and cost allocation |
| [Us] Rated Supply Voltage | 90...277 V AC 50/60 Hz +/- 1 % |
| Device Application | sub billing |
| Device Short Name | BCPMSCE |
| Communication Port Support | RS485 || ETHERNET |
| Measurement Voltage | 90-277 V phase to neutral || 150-480 V phase to phase |
| Sampling Rate | 256 samples/cycle |
| Communication Port Protocol | Modbus RTU || BACnet IP || BACnet MS/TP || Modbus TCP || SNMP v2 |
| Communication Of Data | under voltage alarm || low-low current alarm || high-high current alarm || high current alarm || low current alarm || over voltage alarm |
| Provided Equipment | 2 x adapter board || 0 x current transformer |
| Measurement Accuracy | branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V |
| Update Time | 1.8 s |
| Analogue Input Type | current 0.333 V42 x || current 1 V |
I nostri articoli usati in precedenza e le opzioni di riparazione sono coperti da 12 mesi di garanzia Obso.
“Servizio super! Tutto è stato elaborato in modo molto rapido e competente e il supporto personale è stato eccellente. Sceglierei sempre di nuovo Obso Automation! Molte grazie per l'ottimo supporto”. - MJ
Se necessario, sono disponibili anche opzioni standard per la consegna.
“Professionale, cortese e preciso. Pezzo obsoleto quotato il giorno stesso e fornito il giorno successivo” - PT
1
Step 1
Parte aggiunta per richiesta
2
Passo 2
Il vostro Account Manager personale è già al lavoro, fornendo risposte rapide e un servizio imbattibile.
3
Passo 3
Non ci limitiamo a elaborare gli ordini, ma garantiamo una consegna senza intoppi, piena trasparenza e zero grattacapi.
4
Passo 4
Più di 10.000 clienti si fidano di noi per un motivo. Richiedete subito il vostro preventivo e sperimentate l’automazione senza rischi, ritardi o incertezze.
Google Reviews