6SL32201YE600CP0
SIEMENS
G120X IP20 380...480V 400kW FSH C3
Disponibile
Richiedi un preventivo adesso
- "SINAMICS G120X Rated power: 400 kW at 135% 3 sec or 110% 60 sec. 100% 240 sec; RFI suppression filter For category C3 3AC380-480V+10/-20% 47-63Hz Ambient temperature 0 to +45 \u00b0C Size: FSH Degree of protection IP20 / UL open type Without operator panel Without IO expansion Integrated fieldbus: PROFIBUS DP"
| Specification | Value |
|---|---|
| Country of Origin | DE |
| Depth | 393 mm |
| Width | 548 mm |
| Height | 1695 mm |
| Mains voltage | 380 V |
| Mains frequency | 50/60 Hz |
| Number of phases input | 3 |
| With PC connection | false |
| Number of phases output | 3 |
| Number of digital inputs | 6 |
| Max. output frequency | 100 Hz |
| Number of analogue inputs | 2 |
| Number of analogue outputs | 1 |
| With optical interface | false |
| Number of HW-interfaces USB | 0 |
| Type of converter | U converter |
| Degree of protection (IP) | IP20 |
| Nominal output current I2N | 735 A |
| Number of HW-interfaces other | 6 |
| Number of interfaces PROFINET | 0 |
| Number of HW-interfaces RS-232 | 1 |
| Number of HW-interfaces RS-422 | 0 |
| Number of HW-interfaces RS-485 | 1 |
| Supporting protocol for ASI | false |
| Supporting protocol for CAN | false |
| Supporting protocol for KNX | false |
| Supporting protocol for LON | false |
| Number of HW-interfaces parallel | 0 |
| 4-quadrant operation possible | false |
| Integrated breaking resistance | false |
| Number of HW-interfaces serial TTY | 5 |
| Supporting protocol for MODBUS | false |
| Supporting protocol for SERCOS | false |
| Supporting protocol for TCP/IP | false |
| Supporting protocol for PROFIBUS | true |
| Supporting protocol for SUCONET | false |
| Supporting protocol for INTERBUS | false |
| Supporting protocol for DeviceNet | false |
| Supporting protocol for PROFIsafe | false |
| Supporting protocol for EtherNet/IP | false |
| Supporting protocol for PROFINET IO | false |
| Supporting protocol for SafetyBUS p | false |
| Supporting protocol for Data-Highway | false |
| Supporting protocol for PROFINET CBA | false |
| Application in industrial area permitted | true |
| Number of HW-interfaces industrial Ethernet | 0 |
| Relative symmetric net frequency tolerance | 5 % |
| Relative symmetric net voltage tolerance | -10 % |
| Supporting protocol for INTERBUS-Safety | false |
| Supporting protocol for DeviceNet Safety | false |
| Supporting protocol for other bus systems | false |
| Supporting protocol for Foundation Fieldbus | false |
| Max. output at linear load at rated output voltage | 315 kW |
| Supporting protocol for AS-Interface Safety at Work | false |
| Max. output at quadratic load at rated output voltage | 400 kW |
| Application in domestic- and commercial area permitted | false |
I nostri articoli usati in precedenza e le opzioni di riparazione sono coperti da 12 mesi di garanzia Obso.
“Servizio super! Tutto è stato elaborato in modo molto rapido e competente e il supporto personale è stato eccellente. Sceglierei sempre di nuovo Obso Automation! Molte grazie per l'ottimo supporto”. - MJ
Se necessario, sono disponibili anche opzioni standard per la consegna.
“Professionale, cortese e preciso. Pezzo obsoleto quotato il giorno stesso e fornito il giorno successivo” - PT
1
Step 1
Parte aggiunta per richiesta
2
Passo 2
Il vostro Account Manager personale è già al lavoro, fornendo risposte rapide e un servizio imbattibile.
3
Passo 3
Non ci limitiamo a elaborare gli ordini, ma garantiamo una consegna senza intoppi, piena trasparenza e zero grattacapi.
4
Passo 4
Più di 10.000 clienti si fidano di noi per un motivo. Richiedete subito il vostro preventivo e sperimentate l’automazione senza rischi, ritardi o incertezze.
Google Reviews