XPSUEP14AP
Schneider Electric
safety module, Harmony XPSU, Cat 4, expansion use with universal range, 24V AC or DC, screw
Disponible
Obtenga una cotización ahora
- "This safety relay is designed for extending the number of safety contacts. The safety relay is powered with 24V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds a safety extension bus, 4 NO and 2 single NC safety outputs. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, T\u00dcV, EAC, CCC and KC marking. XPSUEP can be only used with XPSUAF, XPSUAK, XPSUAT, XPSUDN and XPSUS safety modules. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines."
| Specification | Value |
|---|---|
| Height | 100 mm |
| Mounting Support | 35 mm symmetrical DIN rail |
| Minimum Output Voltage | 12 V relay output |
| Minimum Output Current | 10 mA relay output |
| [Ith] Conventional Free Air Thermal Current | 8 A |
| Associated Fuse Rating | 10 A gG NO relay output circuit IEC 60947-1 || 4 A gG NC relay output circuit IEC 60947-1 |
| [Uimp] Rated Impulse Withstand Voltage | 4 kV II IEC 60947-1 |
| Net Weight | 0.200 kg |
| Number Of Inputs | 0 extension bus 24 V DC 5 |
| Input Compatibility | normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP |
| Power Consumption In Va | 3.5 VA 24 V AC 50/60 Hz |
| [Ie] Rated Operational Current | 5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact |
| Auxiliary Contact Composition | 4 NO redundant || 2 NC single |
| [Ui] Rated Insulation Voltage | 250 V 2)IEC 60947-1 |
| Power Consumption In W | 1.5 W 24 V DC |
| Maximum Line Resistance | 60 Ohm |
| Local Signalling | for power ON LED (green) || for error LED (red) || for safety output status LED (yellow) |
| Input Protection Type | internal, electronic |
| Width | 22.5 mm |
| Depth | 120 mm |
| Maximum Response Time On Input Open | 20 ms |
| [Us] Rated Supply Voltage | 24 V AC - 15...10 % || 24 V DC - 20...20 % |
| Range Of Product | Harmony Safety Automation |
| Product Or Component Type | safety module |
| Safety Module Name | XPSUEP |
| Connections - Terminals | removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel |
| Safety Module Application | for extending number of safety contacts |
| Safety Reliability Data | MTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 0.97E-09 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 0.97E-09 IEC 62061 || SFF > 99% IEC 62061 || HFT = 1 IEC 61508-1 || PFHd = 0.97E-09 IEC 61508-1 || SFF > 99% IEC 61508-1 || type = B IEC 61508-1 |
| Electrical Circuit Type | addition to Preventa XPSU base module |
| Function Of Module | safety output extension |
| Safety Level | can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay contact ISO 13849-1 || can reach SILCL 1 for normally closed relay contact IEC 62061 || can reach SIL 1 for normally closed relay contact IEC 61508 |
Nuestros artículos usados y opciones de reparación tienen 12 meses de garantía Obso.
«¡Súper servicio! Todo se tramitó de forma muy rápida y competente y la asistencia personal fue excelente. Siempre volvería a elegir Obso Automation. Muchas gracias por el gran apoyo». - MJ
Si lo desea, también disponemos de opciones de entrega estándar.
«Profesional, cortés y preciso. Pieza obsoleta presupuestada el mismo día y suministrada al día siguiente» - PT
1
Step 1
Parte agregado para la investigación
2
Paso 2
Su gestor de cuenta personal ya está en ello, ofreciéndole respuestas rápidas y un servicio inmejorable.
3
Paso 3
No nos limitamos a tramitar pedidos: garantizamos una entrega fluida, total transparencia y cero quebraderos de cabeza.
4
Paso 4
Nuestros más de 10.000 clientes confían en nosotros por una razón. Obtenga su presupuesto ahora y experimente la automatización sin riesgos, retrasos ni incertidumbre.
Google Reviews