LTMR08EFM

Schneider Electric

Motor controller, TeSys T, Motor Management, Ethernet/IP, Modbus/TCP, 6 inputs, 3 outputs, 0.4 to 8A, 100 to 240VAC

Disponible

Obtenga una cotización ahora

  • "TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. It manages most critical processes while reducing downtime and increasing productivity as well as predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This motor management system is also a flexible system that supports six communication protocols which are Modbus\u2122, CANopen, DeviceNet\u2122, Profibus\u2122, Ethernet/IP, and Modbus/TCP. TeSys T motor management system consist of several components which include the LTMR controller, the expansion module, HMI and software along with several accessories. The LTMR controller is the main component of the system that manages the basic functions. This includes the measurement of the ground current, motor temperature, three phase current of the motor, the controller also includes logic inputs and outputs which is used in fault management. The expansion module is directly connected to the controller and provides additional inputs as well as measure the voltage between the phases which allow the controller the monitor additional functions. TeSys T is highly reliable and has a very long product life thanks to a state-of-the-art component selection, to the all in one design and to the advanced electronic protection. TeSys T can be integrated in many different types of harsh environment such as dusty atmospheres, marine applications, high vibration applications and corrosive atmospheres and is used in Metal/Mining/Mineral, Oil & Gas, Water Wastewater. This is a TeSys T LTMR controller that measure current range of 0.4-8A with a supply voltage of 100-240 Vac and uses EtherNet/Modbus TCP/IP as the communication protocol. This controller measures temperature, phase current, imbalance current, average current and earth-fault current. The dimensions of this device are 61 mm (H) X 91 mm (W) X 122.5 mm (D) and it weighs 0.53 kg. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC."
Más información arrow Leer más arrow
Specification Value
Contacts Type And Composition 1 NO + 1 NC fault signal || 3 NO
Height 61 mm
Connection Pitch 5.08 mm
Permissible Power 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Network And Machine Diagnosis Type trip context information || phase fault and earth fault trip counters || trip history information || event recording || remaining operating time before overload tripping || starting current and time || fault recording || waiting time after overload tripping || running hours counter/operating time || motor control command recording
Pollution Degree 3
Logic Input Number 6
Maximum Operating Rate 1800 cyc/h
Connections - Terminals control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end
Input Current 3.1 mA 100 V || 7.5 mA 240 V
Current State 1 Guaranteed logic input 79...264 V >= 2 mA 25 ms
Net Weight 0.53 kg
[Uimp] Rated Impulse Withstand Voltage 4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1
Associated Fuse Rating 4 A gG output || 0.5 A gG control circuit
Electromagnetic Compatibility electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Measurement Accuracy 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
Current State 0 Guaranteed logic input 0...40 V <= 15 mA 25 ms
[Ui] Rated Insulation Voltage 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Short-Circuit Withstand 100 kA conforming to EN/IEC 60947-4-1
Compatibility Code LTMR
Protection Type thermal overload protection || overload || thermal protection || locked rotor || phase failure || phase unbalance || load fluctuation || reverse polarity protection || overload (long time) || earth-leakage protection || power factor variation
Web Services web server
Width 91 mm
Load Current 5 A 250 V AC logic output || 5 A 30 V DC logic output
Tightening Torque control circuit 0.5-0.6 N.m flat 3 mm
Overvoltage Category III
Depth 122.5 mm
Maximum Operating Frequency 2 Hz
Metering Type earth-fault current || imbalance current || temperature || average current Iavg || phase current I1, I2, I3 RMS
Product Or Component Type motor controller
Product Name TeSys T
Measurement Current 0.4-8 A
Range TeSys
Current Consumption 8...62.8 mA
[Us] Rated Supply Voltage 100...240 V AC 50/60 Hz
Communication Port Protocol Modbus TCP/EtherNet/IP
Bus Type Ethernet IEEE 802.3 0...159 10...100 Mbit/s, RJ45 2 shielded twisted pairs
Supply Voltage Limits 93.5-264 V AC
Device Application equipment monitoring and control
Device Short Name LTMR
Más información arrow Leer más arrow
*Los artículos nuevos tienen hasta 24 meses de garantía Obso.
Nuestros artículos usados y opciones de reparación tienen 12 meses de garantía Obso.


«¡Súper servicio! Todo se tramitó de forma muy rápida y competente y la asistencia personal fue excelente. Siempre volvería a elegir Obso Automation. Muchas gracias por el gran apoyo». - MJ
*Entrega y recogida el mismo día y al día siguiente en nuestras sucursales del Reino Unido y Países Bajos. La entrega y recogida al día siguiente y la entrega en 2 días están disponibles para las existencias procedentes de nuestros socios. En el 90% de los casos, podemos entregar más rápido que el tiempo estimado de llegada del fabricante cuando sea necesario.

Si lo desea, también disponemos de opciones de entrega estándar.


«Profesional, cortés y preciso. Pieza obsoleta presupuestada el mismo día y suministrada al día siguiente» - PT
Contamos con la acreditación ISO 9001 para que usted esté tranquilo con su compra.

Que dicen los clientes sobre nosotros

Trustpilot

1

Step 1

    Parte agregado para la investigación

    2

    Paso 2

    Su gestor de cuenta personal ya está en ello, ofreciéndole respuestas rápidas y un servicio inmejorable.

    3

    Paso 3

    No nos limitamos a tramitar pedidos: garantizamos una entrega fluida, total transparencia y cero quebraderos de cabeza.

    4

    Paso 4

    Nuestros más de 10.000 clientes confían en nosotros por una razón. Obtenga su presupuesto ahora y experimente la automatización sin riesgos, retrasos ni incertidumbre.