- "This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for retrofit and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (including 50A, 100A or 200A split-core current transformers) on all branch channels. The BCPM monitors both the 42 branch circuits and mains values, incoming power and energy. All to provide information on the complete Power Distribution Unit. Adapter boards with terminals for split-core CTs can be mounted using DIN-rail, Snaptrack or on a common mounting plate with the main board Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with serial connection for either Modbus RTU or BACnet MS/TP, and an Ethernet connection for Modbus TCP, BACnet IP and SNMP. The meter need to be powered by a 100V AC to 277V AC supply source. Include 50A branch CTs with 2 meters leads and 1.8 meters round ribbon cables, for 42 split-core current transformers. The device dimensions are 353mm in width, 253mm in height, 71mm in depth and weight 1.5 kilograms."
| Specification | Value |
|---|---|
| Network Frequency | 60 Hz || 50 Hz |
| Power Quality Analysis | voltage sag and swell detection |
| Variant | advanced + ethernet |
| Type Of Measurement | voltage || current || frequency || active power || power factor || active energy |
| Power Monitoring | basic instrumentation |
| Product Or Component Type | multi-circuit energy meter |
| Product Name | PowerLogic BCPMSC |
| Range | PowerLogic |
| Energy Management | sub billing and cost allocation |
| [Us] Rated Supply Voltage | 90...277 V AC 50/60 Hz +/- 1 % |
| Device Application | sub billing |
| Device Short Name | BCPMSCE |
| Communication Port Support | RS485 || ETHERNET |
| Measurement Voltage | 90-277 V phase to neutral || 150-480 V phase to phase |
| Sampling Rate | 256 samples/cycle |
| Communication Port Protocol | Modbus RTU || BACnet IP || BACnet MS/TP || Modbus TCP || SNMP v2 |
| Communication Of Data | over voltage alarm || low-low current alarm || low current alarm || under voltage alarm || high-high current alarm || high current alarm |
| Provided Equipment | 42 x current transformer || 2 x cables || 2 x adapter board |
| Measurement Accuracy | branch current 2 % 0.25…2 A || branch current 1 % 2…100 A || mains current 3 % 1…100 % || mains current 3 % 2…100 % || voltage 1 % 90…277 V |
| Update Time | 1.8 s |
| Analogue Input Type | split core CT 0.333 V42 x |
Nuestros artículos usados y opciones de reparación tienen 12 meses de garantía Obso.
«¡Súper servicio! Todo se tramitó de forma muy rápida y competente y la asistencia personal fue excelente. Siempre volvería a elegir Obso Automation. Muchas gracias por el gran apoyo». - MJ
Si lo desea, también disponemos de opciones de entrega estándar.
«Profesional, cortés y preciso. Pieza obsoleta presupuestada el mismo día y suministrada al día siguiente» - PT
1
Step 1
Parte agregado para la investigación
2
Paso 2
Su gestor de cuenta personal ya está en ello, ofreciéndole respuestas rápidas y un servicio inmejorable.
3
Paso 3
No nos limitamos a tramitar pedidos: garantizamos una entrega fluida, total transparencia y cero quebraderos de cabeza.
4
Paso 4
Nuestros más de 10.000 clientes confían en nosotros por una razón. Obtenga su presupuesto ahora y experimente la automatización sin riesgos, retrasos ni incertidumbre.
Google Reviews