- "This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for retrofit and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (including 50A, 100A or 200A split-core current transformers) on all branch channels. The BCPM allow the monitoring of both the branch circuits and mains values, incoming power and energy for a maximum of 84 circuits. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with serial connection for either Modbus RTU or BACnet MS/TP, and an Ethernet connection for Modbus TCP, BACnet IP and SNMP. The meter need to be powered by a 100V AC to 277V AC supply source. This version is for 84 circuits, but do not include branch current transformers nor ribbon. The device dimensions are 353mm in width, 253mm in height, 71mm in depth and weight 1.5 kilograms."
| Specification | Value |
|---|---|
| Network Frequency | 50 Hz || 60 Hz |
| Power Quality Analysis | voltage sag and swell detection |
| Variant | advanced + ethernet |
| Type Of Measurement | voltage || current || frequency || active power || power factor || active energy |
| Power Monitoring | basic instrumentation |
| Product Or Component Type | multi-circuit energy meter |
| Product Name | PowerLogic BCPMSC |
| Range | PowerLogic |
| Energy Management | sub billing and cost allocation |
| [Us] Rated Supply Voltage | 90...277 V AC 50/60 Hz +/- 1 % |
| Device Application | sub billing |
| Device Short Name | BCPMSCE |
| Communication Port Support | RS485 || ETHERNET |
| Measurement Voltage | 90-277 V phase to neutral || 150-480 V phase to phase |
| Sampling Rate | 256 samples/cycle |
| Communication Port Protocol | Modbus RTU || BACnet IP || BACnet MS/TP || Modbus TCP || SNMP v2 |
| Communication Of Data | under voltage alarm || high current alarm || high-high current alarm || low-low current alarm || over voltage alarm || low current alarm |
| Provided Equipment | 4 x adapter board || 0 x current transformer |
| Measurement Accuracy | branch current 2 % 0.25…2 A || branch current 2 % 2…100 A || mains current 2 % 1…100 % || mains current 2 % 2…100 % || voltage 2 % 90…277 V |
| Update Time | 1.8 s |
| Analogue Input Type | current 1 V || current 0.333 V84 x |
Nuestros artículos usados y opciones de reparación tienen 12 meses de garantía Obso.
«¡Súper servicio! Todo se tramitó de forma muy rápida y competente y la asistencia personal fue excelente. Siempre volvería a elegir Obso Automation. Muchas gracias por el gran apoyo». - MJ
Si lo desea, también disponemos de opciones de entrega estándar.
«Profesional, cortés y preciso. Pieza obsoleta presupuestada el mismo día y suministrada al día siguiente» - PT
1
Step 1
Parte agregado para la investigación
2
Paso 2
Su gestor de cuenta personal ya está en ello, ofreciéndole respuestas rápidas y un servicio inmejorable.
3
Paso 3
No nos limitamos a tramitar pedidos: garantizamos una entrega fluida, total transparencia y cero quebraderos de cabeza.
4
Paso 4
Nuestros más de 10.000 clientes confían en nosotros por una razón. Obtenga su presupuesto ahora y experimente la automatización sin riesgos, retrasos ni incertidumbre.
Google Reviews