56270
Schneider Electric
Residual current protection relay, VigiPacT RH99P, 30mA-30A, 12/24VAC 50/60Hz, 12/48VDC, front panel mounting
Disponible
Obtenga una cotización ahora
- "VigiPacT RH99P is a front panel mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is 12/24VAC 50/60Hz, or 12/48VDC. It is a type A earth-leakage protection class. The current sensitivity is selectable with 9 thresholds from 30 mA to 30 A. The time delay is selectable with 9 settings from instantaneous to 4.5s. It requires a local manual reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a front panel switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor."
| Specification | Value |
|---|---|
| Ik Degree Of Protection | IK07 EN 50102 |
| Mechanical Robustness | fire resistance IEC 60695-2-1 || IK protection 2 joulesIK07 EN 50102 || vibrations 13.2...100 Hz0.7 g || vibrations 2...13.2 Hz+/- 1 mm |
| Height | 72 mm |
| Standards | EN/IEC 60947-2 Annex M || EN/IEC 60755 || UL 1053 || CAN/CSA C22.2 No. 144 |
| Type Of Measurement | earth fault current internal measurement 80...100 % |
| Net Weight | 0.3 kg |
| Tamperproof Of Settings | protected by sealable cover |
| Wire Stripping Length | auxiliary power supply: 7 mm || fault: 7 mm || relay test and fault reset: 7 mm || sensor: 7 mm || voltage presence: 7 mm |
| Connections - Terminals | auxiliary power supply terminal block 0.2-2.5 mm² flexible AWG 24...AWG 12 || auxiliary power supply terminal block 0.2-2.5 mm² rigid AWG 24...AWG 12 || auxiliary power supply terminal block 0.25-2.5 mm² flexible AWG 24...AWG 12 || fault terminal block 0.2-2.5 mm² flexible AWG 24...AWG 12 || fault terminal block 0.2-2.5 mm² rigid AWG 24...AWG 12 || fault terminal block 0.25-2.5 mm² flexible AWG 24...AWG 12 || relay test and fault reset terminal block 0.2-2.5 mm² flexible AWG 24...AWG 12 || relay test and fault reset terminal block 0.2-2.5 mm² rigid AWG 24...AWG 12 || relay test and fault reset terminal block 0.25-2.5 mm² flexible AWG 24...AWG 12 || sensor terminal block 0.2-2.5 mm² flexible AWG 24...AWG 12 || sensor terminal block 0.2-2.5 mm² rigid AWG 24...AWG 12 || sensor terminal block 0.25-2.5 mm² flexible AWG 24...AWG 12 || voltage presence terminal block 0.2-2.5 mm² flexible AWG 24...AWG 12 || voltage presence terminal block 0.2-2.5 mm² rigid AWG 24...AWG 12 || voltage presence terminal block 0.25-2.5 mm² flexible AWG 24...AWG 12 |
| Cut-Out Dimensions | 68 x 68 mm |
| Ip Degree Of Protection | on front face IP40 EN/IEC 60529 || on side parts IP30 EN/IEC 60529 || on connection terminals IP20 EN/IEC 60529 |
| Test Function | remote test || local |
| Monitoring | electronics continuous) || power supply continuous) || relay/sensor link continuous) |
| Width | 72 mm |
| Depth | 78 mm |
| Tightening Torque | auxiliary power supply: 0.6-0.6 N.m || fault: 0.6-0.6 N.m || relay test and fault reset: 0.6-0.6 N.m || sensor: 0.6-0.6 N.m || voltage presence: 0.6-0.6 N.m |
| Type Of Setting | selector |
| Reset | manual reset |
| Earth Leakage Current | 0.03-30 A |
| Mounting Support | front panel |
| Range Compatibility | VigiPacT TOA earth leakage current sensor || VigiPacT A earth leakage current sensor || VigiPacT L earth leakage current sensor |
| Earth-Leakage Protection Class | type A |
| Network Rated Voltage | 1000-1000 V - AC 50/60 Hz maximum) || 1000-1000 V - AC 400 Hz maximum) |
| [Ithe] Conventional Enclosed Thermal Current | 8 A |
| Earthing System | IT || TN-S || TT |
| Relay Application | protection relay |
| Product Or Component Type | residual current protection relay |
| Range | VigiPacT |
| Residual Earth-Leakage Time Delay Adjustment Type | instantaneous for 0.03-0.03 A || adjustable 9 settings 0-4.5 s for 0.03-30 A |
| Residual Earth-Leakage Sensitity Adjustment Type | adjustable 9 settings |
| Power Consumption In Va | 4 VA |
| [Us] Rated Supply Voltage | 12...24 V AC 50/60 Hz 55...120 % || 12...48 V DC 55...120 % |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
| Minimum Load | 10 mA 12 V |
| Device Short Name | RH99P |
Nuestros artículos usados y opciones de reparación tienen 12 meses de garantía Obso.
«¡Súper servicio! Todo se tramitó de forma muy rápida y competente y la asistencia personal fue excelente. Siempre volvería a elegir Obso Automation. Muchas gracias por el gran apoyo». - MJ
Si lo desea, también disponemos de opciones de entrega estándar.
«Profesional, cortés y preciso. Pieza obsoleta presupuestada el mismo día y suministrada al día siguiente» - PT
1
Step 1
Parte agregado para la investigación
2
Paso 2
Su gestor de cuenta personal ya está en ello, ofreciéndole respuestas rápidas y un servicio inmejorable.
3
Paso 3
No nos limitamos a tramitar pedidos: garantizamos una entrega fluida, total transparencia y cero quebraderos de cabeza.
4
Paso 4
Nuestros más de 10.000 clientes confían en nosotros por una razón. Obtenga su presupuesto ahora y experimente la automatización sin riesgos, retrasos ni incertidumbre.
Google Reviews