Specification Value
Product Certifications CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
Height 224 mm
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Maximum Operating Rate 3600 cyc/h
Connections - Terminals power circuit screw clamp terminals 1 1-10 mm² rigid || power circuit screw clamp terminals 1 1-6 mm² flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² rigid || power circuit screw clamp terminals 2 1.5-6 mm² flexible without cable end || control circuit without connection
Net Weight 1.27 kg
Fixing Mode clipped DIN rail) || screw-fixed plate)
[Uimp] Rated Impulse Withstand Voltage 6 kVIEC 60947-6-2
Inrush Restraint Duration 15 ms DC
Standards EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
[Ui] Rated Insulation Voltage 690 V IEC 60947-6-2 3) || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Typical Current Consumption 120 mA 24 V DC I maximum while closing || 120 mA 24 V DC I rms sealed
Mechanical Durability 15 Mcycles
Compatibility Code LU2B
Operating Time 150 ms with change of direction power circuit || 75 ms without change of direction power circuit || 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit || 75 ms closing with LUCM control circuit || 70 ms closing with LUCA, LUCB, LUCC, LUCD control circuit
Width 45 mm
Tightening Torque power circuit 1.9-2.5 N.m flat 6 mm || power circuit 1.9-2.5 N.m Philips No 2 6 mm || power circuit 1.9-2.5 N.m pozidriv No 2 6 mm
Safe Separation Of Circuit 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
Depth 126 mm
Heat Dissipation 2-2 W control circuit with LUCA, LUCB, LUCC, LUCD || 1.7-1.7 W control circuit with LUCM
[Ics] Rated Service Breaking Capacity 50 kA 230 V || 50 kA 440 V || 10 kA 500 V || 4 kA 690 V
[Ue] Rated Operational Voltage 690 V AC power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Uc] Control Circuit Voltage 24 V DC
Product Or Component Type reversing power base
[Ith] Conventional Free Air Thermal Current 12 A
Product Name TeSys Ultra
Range TeSys
Utilisation Category AC-43 || AC-44 || AC-41
[Ie] Rated Operational Current 12 A <= 440 V || 12 A 500 V || 9 A 690 V
Suitability For Isolation yes
Product Compatibility control unit LUC.X6BL || control unit LUC.1XBL || control unit LUC.05BL || control unit LUC.12BL
Auxiliary Contacts Type linked contacts 1 NO + 1 NC) IEC 60947-4-1 || mirror contact 1 NC) IEC 60947-1
Poles Description 3P
Control Circuit Voltage Limits 14.5 V DC drop-out || 20...27 V DC in operation
Network Frequency 40...60 Hz
Device Application motor control || motor protection
Device Short Name LU2B
Lesen Sie mehr arrow Weniger lesen arrow
*Neue Artikel haben bis zu 24 Monate Obso-Garantie
Auf unsere gebrauchten Artikel und Reparaturoptionen gewähren wir 12 Monate Obso-Garantie.


„Super Service! Alles wurde sehr schnell und kompetent abgewickelt und die persönliche Betreuung war hervorragend. Ich würde mich jederzeit wieder für Obso Automation entscheiden! Vielen Dank für die tolle Unterstützung.“ - MJ
*Die Lieferung und Abholung am selben oder nächsten Tag ist für Lagerbestände in unseren Niederlassungen in Großbritannien und den Niederlanden möglich. Abholung am nächsten Tag und Lieferung innerhalb von 2 Tagen ist möglich, wenn die Ware von unseren Partnern bezogen wird. In 90 % der Fälle können wir bei Bedarf schneller liefern als die vom Hersteller angegebene Lieferfrist.

Bei Bedarf sind auch Standardoptionen für die Lieferung verfügbar.


„Professionell, zuvorkommend und genau. Veraltetes Teil am selben Tag angeboten und am nächsten Tag geliefert“ - PT
Wir sind ISO 9001-zertifiziert, so dass Sie sich bei Ihrem Kauf keine Sorgen machen müssen.

Was unsere Kunden über uns sagen

Trustpilot

1

Step 1

    Bauteil zur Anfrage hinzugefügt

    2

    Seite 2

    Ihr persönlicher Kundenbetreuer ist bereits dabei und sorgt für schnelle Antworten und einen unschlagbaren Service.

    3

    Seite 3

    Wir wickeln nicht nur Aufträge ab – wir garantieren eine reibungslose Lieferung, volle Transparenz und keine Kopfschmerzen.

    4

    Seite 4

    Mehr als 10.000 Kunden vertrauen uns aus gutem Grund. Fordern Sie jetzt Ihr Angebot an und erleben Sie Automatisierung ohne Risiko, Verzögerungen oder Unsicherheit.