LC2D150BD

Schneider Electric

TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V DC coil

Verfügbar

Jetzt Angebot einholen

  • "LC2D150BD is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications. Rated 150A AC-3 75kW@400V, it includes a 24V DC coil, 2NO+2NC aux contacts, mechanical and electrical interlock. LC2D150BD is a 3-pole TeSys D reversing contactor from Schneider Electric for motor applications up to 75kW@400V. It includes a 24V DC coil and 2NO+2NC built-in auxiliary contacts, NC mirror certified. Compact, DIN-rail mounting, with mechanical and electrical interlock and pre-wired reversing circuit, it procures reliability and durability. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Compact product, 266mm wide, for DIN-rail and panel mounting. Assembled with mechanical and electrical interlock and pre-wired reversing circuit. Clear separation between power and control circuits, easy front access to coil and auxiliary contacts connections. Equipped with a 24V DC coil for easy integration to all control systems. Provides 4 built-in auxiliary contacts 2NO + 2NC, NC contacts are mirror certified suitable to be included in the control of safety systems. High electrical durability, guaranteed for 0.8 million cycles at 150A AC-3 440V, for demanding motor switching applications. Robust design with high making and breaking capacities up to 20 In. Connection by screw clamp terminals."
Lesen Sie mehr arrow Weniger lesen arrow
Specification Value
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Minimum Switching Current 5 mA for signalling circuit
Control Circuit Voltage Limits 0.15...0.4 Uc -40-70 °C drop-out DC || 0.75...1.2 Uc -40-55 °C operational DC || 1...1.2 Uc 55-70 °C operational DC
Hold-In Power Consumption In W 2.4-5.1 W 20 °C
Insulation Resistance > 10 MOhm for signalling circuit
Coil Technology without built-in suppressor module
Time Constant 25 ms
Minimum Switching Voltage 17 V for signalling circuit
Signalling Circuit Frequency 25...400 Hz
Inrush Power In W 270-365 W 20 °C
Auxiliary Contacts Type mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Interlocking Type mechanical || electrical
[Uc] Control Circuit Voltage 24 V DC
[Ue] Rated Operational Voltage power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
Power Dissipation Per Pole 24 W AC-1 || 13.5 W AC-3
Average Impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current 200 A (at 60 °C) for power circuit
Mounting Support rail || plate
Control Circuit Type DC standard
Standards CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application motor control || resistive load
Rated Breaking Capacity 1400 A at 440 V for power circuit conforming to IEC 60947
Product Or Component Type reversing contactor
Product Certifications BV || CCC || CSA || DNV || GL || RINA || UL || EAC || UKCA
Irms Rated Making Capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 1660 A at 440 V for power circuit conforming to IEC 60947
Product Name TeSys Deca
Associated Fuse Rating 10 A gG for signalling circuit conforming to IEC 60947-5-1 || 315 A gG at <= 690 V coordination type 1 for power circuit || 250 A gG at <= 690 V coordination type 2 for power circuit
[Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
Connections - Terminals control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm²flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible without cable end || control circuit screw clamp terminals 1 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || power circuit connector 1 10-120 mm²flexible without cable end || power circuit connector 2 10-50 mm²flexible without cable end || power circuit connector 1 10-120 mm²flexible with cable end || power circuit connector 2 10-50 mm²flexible with cable end || power circuit connector 1 10-120 mm²solid without cable end || power circuit connector 2 10-50 mm²solid without cable end
Range TeSys
Pole Contact Composition 3 NO
Device Presentation preassembled with reversing power busbar
Utilisation Category AC-3 || AC-1
Operating Time 20...35 ms closing || 40...75 ms opening
[Ie] Rated Operational Current 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
Maximum Operating Rate 1200 cyc/h 60 °C
Electrical Durability 0.85 Mcycles 150 A AC-3 <= 440 V || 1 Mcycles 200 A AC-1 <= 440 V
Tightening Torque control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Poles Description 3P
Overvoltage Category III
Motor Power Kw 40 kW at 220...230 V AC 50 Hz || 75 kW at 380...400 V AC 50 Hz || 80 kW at 415...440 V AC 50 Hz || 90 kW at 500 V AC 50 Hz || 100 kW at 660...690 V AC 50 Hz || 75 kW at 1000 V AC 50 Hz
Maximum Horse Power Rating 40 hp at 200/208 V AC 60 Hz for 3 phase motors || 50 hp at 230/240 V AC 60 Hz for 3 phase motors || 100 hp at 460/480 V AC 60 Hz for 3 phase motors || 125 hp at 575/600 V AC 60 Hz for 3 phase motors
[Ui] Rated Insulation Voltage power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL || power circuit 1000 V IEC 60947-4-1
Mechanical Durability 8000000 cycles
Device Short Name LC2D
[Icw] Rated Short-Time Withstand Current 250 A 40 °C - 10 min for power circuit || 580 A 40 °C - 1 min for power circuit || 1200 A 40 °C - 10 s for power circuit || 1400 A 40 °C - 1 s for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit
Protective Cover with
Lesen Sie mehr arrow Weniger lesen arrow
*Neue Artikel haben bis zu 24 Monate Obso-Garantie
Auf unsere gebrauchten Artikel und Reparaturoptionen gewähren wir 12 Monate Obso-Garantie.


„Super Service! Alles wurde sehr schnell und kompetent abgewickelt und die persönliche Betreuung war hervorragend. Ich würde mich jederzeit wieder für Obso Automation entscheiden! Vielen Dank für die tolle Unterstützung.“ - MJ
*Die Lieferung und Abholung am selben oder nächsten Tag ist für Lagerbestände in unseren Niederlassungen in Großbritannien und den Niederlanden möglich. Abholung am nächsten Tag und Lieferung innerhalb von 2 Tagen ist möglich, wenn die Ware von unseren Partnern bezogen wird. In 90 % der Fälle können wir bei Bedarf schneller liefern als die vom Hersteller angegebene Lieferfrist.

Bei Bedarf sind auch Standardoptionen für die Lieferung verfügbar.


„Professionell, zuvorkommend und genau. Veraltetes Teil am selben Tag angeboten und am nächsten Tag geliefert“ - PT
Wir sind ISO 9001-zertifiziert, so dass Sie sich bei Ihrem Kauf keine Sorgen machen müssen.

Was unsere Kunden über uns sagen

Trustpilot

1

Step 1

    Bauteil zur Anfrage hinzugefügt

    2

    Seite 2

    Ihr persönlicher Kundenbetreuer ist bereits dabei und sorgt für schnelle Antworten und einen unschlagbaren Service.

    3

    Seite 3

    Wir wickeln nicht nur Aufträge ab – wir garantieren eine reibungslose Lieferung, volle Transparenz und keine Kopfschmerzen.

    4

    Seite 4

    Mehr als 10.000 Kunden vertrauen uns aus gutem Grund. Fordern Sie jetzt Ihr Angebot an und erleben Sie Automatisierung ohne Risiko, Verzögerungen oder Unsicherheit.