XPSUVN31AP

Schneider Electric

safety module, Harmony XPS, zero speed monitoring with time delay, 48 to 240V AC or DC, screw

AVAILABLE

GET A QUOTE NOW

  • "This safety relay is designed for zero speed monitoring with delayed access to dangerous area. The safety relay is powered with 48 to 240V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 3 safety inputs, 1 NO output configurable between 0,5s and 60s, and 2solid state diagnostic outputq with complete status information. The maximum safety level achieved by this safety relay is PLe/Category 3 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061 and SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC 60947-5-1, IEC 61508-1, IEC 61508-2/-3, ISO 13849-1, IEC 62061 functional safety standards, is certified by cULus, T\u00dcV. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines."
Read more arrow Read less arrow
Specification Value
Height 100 mm
[Ith] Conventional Free Air Thermal Current 6 A NO relay output circuit
Mounting Support 35 mm symmetrical DIN rail
Power Consumption In W 2.5 W
Minimum Output Voltage 5 V relay output
Minimum Output Current 10 mA relay output
Time Delay 0.5 s || 1 s || 2 s || 3 s || 5 s || 8 s || 12 s || 20 s || 35 s || 60 s
Associated Fuse Rating 6 A gG relay output IEC 60947-1
Local Signalling LED green power power ON || LED red error error || LED yellow state status || LED yellow L12 input line comparison || LED yellow L32 input line comparison
[Uimp] Rated Impulse Withstand Voltage 4 kV II IEC 60947-1
Net Weight 0.2 kg
Standards IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional safety standard || IEC 61508-7 functional safety standard || ISO 13849-1 functional safety standard || IEC 62061 functional safety standard
[Ui] Rated Insulation Voltage 690 V phase to phase 2)IEC 60947-1 || 400 V phase to earth 2)IEC 60947-1
[Ie] Rated Operational Current 5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact
Power Consumption In Va 5.5 VA
Input Voltage 690 V
Connections - Terminals removable screw terminal block solid or flexible 0.2...2.5 mm² || removable screw terminal block flexible with ferrule 0.25...2.5 mm² single conductor || removable screw terminal block solid or flexible 0.2...1.5 mm² twin conductor || removable screw terminal block flexible with ferrule 2 x 0.25...1 mm² without cable end, with bezel || removable screw terminal block flexible with ferrule 2 x 0.5...1.5 mm² with cable end, with bezel
Width 22.5 mm
Depth 120 mm
Input Detection Threshold 50 mV || 65 mV || 85 mV || 110 mV || 140 mV || 180 mV || 230 mV || 300 mV || 400 mV || 500 mV
Product Certifications TÜV || cULus
[Us] Rated Supply Voltage 48...240 V AC/DC - 10...10 %
Range Of Product Harmony Safety Automation
Product Or Component Type safety module
Safety Module Name XPSUVN
Number Of Additional Circuits 2 solid state outputs
Output Type relay, 1 NO, volt-free
Safety Module Application for zero speed detection
Safety Reliability Data MTTFd > 30 years ISO 13849-1 || Dcavg = 98.9 % ISO 13849-1 || PFHd = 2.44E-9 1/h ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 2.44E-9 1/h IEC 62061 || SFF > 99% IEC 62061 || HFT = 1 IEC 61508-1 || PFHd = 2.44E-9 1/h IEC 61508-1 || SFF > 99% IEC 61508-1 || type = B IEC 61508-1
Function Of Module monitoring 3-phase motor || monitoring 3-phase motor with star-delta starting || monitoring 3-phase motor with variable number of poles || monitoring 3-phase motor with variable number of poles and star-delta starting || monitoring dc motor || monitoring servo motor || monitoring 3-phase motor supplied by variable speed drive || monitoring 3-phase motor supplied by servo drive || controlling enegization to open of guard switch type XCSE, XCSLE, XCSLF, XCST
Safety Level can reach PL e/category 3 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508
Read more arrow Read less arrow
*New items come with up to 24 month Obso Warranty
Our previously used items and repair options come with 12 months Obso Warranty.


"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
*Same & Next Day Delivery & Collection is available for stock from our UK and NL branches. Next-day delivery collection and 2 day delivery is available for stock sourced from our partners. In 90% of cases, we can deliver faster than the manufacturer’s ETA where required.

Standard options for delivery are also available where required.


"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
We are ISO 9001 accredited so you have peace of mind with your purchase.

What our customers say about us

Trustpilot

1

Step 1

    Part added for enquiry

    2

    Step 2

    Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.

    3

    Step 3

    We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.

    4

    Step 4

    Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.