XPSUAF13AP

safety module, Harmony XPSU, Cat 4, potential free 2 NC, NO NC, 2 PNP, 24V AC or DC, screw

AVAILABLE

GET A QUOTE NOW

This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch or Safety light curtain. The safety relay is powered with 24V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 2 safety inputs, 3 ON/OFF configurable pulsed outputs, 3 NO safety outputs, and 1 solid state diagnostic output with complete status information. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILC L 3 conforming to IEC 62061, and SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÜV, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.
Read more arrow Read less arrow
Specification Value
Number Of Outputs 3 on/off configurable pulsed output
Height 100 mm
Mounting Support 35 mm symmetrical DIN rail
Minimum Output Voltage 15 V relay output
Minimum Output Current 10 mA relay output
[Ith] Conventional Free Air Thermal Current 8 A
Input/Output Type semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
Associated Fuse Rating 10 A gG NO relay output circuit IEC 60947-1
[Uimp] Rated Impulse Withstand Voltage 4 kV II IEC 60947-1
Net Weight 0.200 kg
Type Of Start automatic/manual/monitored
Number Of Inputs 2 safety input 24 V DC 5
Input Compatibility normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP
Power Consumption In Va 5.0 VA 24 V AC 50/60 Hz
[Ie] Rated Operational Current 5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact
Auxiliary Contact Composition 3 NO
[Ui] Rated Insulation Voltage 250 V 2)IEC 60947-1
Power Consumption In W 2.0 W 24 V DC
Maximum Line Resistance 500 Ohm
Local Signalling for power ON LED (green) || for error LED (red) || for start LED (yellow) || for safety status LED (yellow) || for safety input S12 LED (yellow) || for safety input S22 LED (yellow)
Input Protection Type internal, electronic
Width 22.5 mm
Depth 120 mm
Synchronisation Time Between Inputs 0.5 s || 2 s || 4 s
Maximum Response Time On Input Open 20 ms
[Us] Rated Supply Voltage 24 V AC - 15...10 % || 24 V DC - 20...20 %
Range Of Product Harmony Safety Automation
Product Or Component Type safety module
Safety Module Name XPSUAF
Connections - Terminals removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
Safety Module Application monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring
Safety Reliability Data MTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 1.13E-09 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 1.13E-09 IEC 62061 || SFF > 99% IEC 62061 || HFT = 1 IEC 61508-1 || PFHd = 1.13E-09 IEC 61508-1 || SFF > 99% IEC 61508-1 || type = B IEC 61508-1
Electrical Circuit Type NC pair || PNP pair || antivalent pair || OSSD pair
Function Of Module emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE) || proximity sensor monitoring
Safety Level can reach PL e/category 4 ISO 13849-1 || can reach SILCL 3 IEC 62061 || can reach SIL 3 IEC 61508
Read more arrow Read less arrow
*New items come with up to 24 month Obso Warranty
Our previously used items and repair options come with 12 months Obso Warranty.


"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
*Same & Next Day Delivery & Collection is available for stock from our UK and NL branches. Next-day delivery collection and 2 day delivery is available for stock sourced from our partners. In 90% of cases, we can deliver faster than the manufacturer’s ETA where required.

Standard options for delivery are also available where required.


"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
We are ISO 9001 accredited so you have peace of mind with your purchase.

What our customers say about us

Trustpilot

1

Step 1

    Part added for enquiry

    2

    Step 2

    Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.

    3

    Step 3

    We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.

    4

    Step 4

    Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.