XPSMC32ZC

safety controller, Harmony XPS MC, 24V DC, 32 inputs, 48 LEDs signalling, CANopen

AVAILABLE

GET A QUOTE NOW

This product is part of preventa XPCMC configurable safety controller range. It is a configurable safety controller. It is supplied with 24 V DC. It has 32 safety inputs. It conforms to Category 4 maximum conforming to EN 954-1/EN/ISO 13849-1, PLE safety level conforming to EN/ISO 13849-1 and SIL 3 level conforming to IEC 61508. It embeds 1 RJ45 port for serial link communication with Modbus protocol. Transmission rate are 1200/2400/4800/9600 and 19200bps, and another SUB-D 9-pin male port for CANopen communication. Transmission rate are 20/50/125 and 250kbps. This product measures 153mm depth, 151.5mm height, and 74mm width. It weighs 0.84kg. This safety controller is designed for monitoring multiple safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. This product is certified by CSA, UL and TÜV. It conforms to EN 954-1/EN/ISO 13849-1, EN/IEC 61496-1, IEC 61508, EN/IEC 60204-1, EN 1760-1/ISO 13856-1, EN 574/ISO 13851 and EN/IEC 60947-5-1 standards. The Safety controller XPSMC is configurable and addressable using software XPSMCWIN running on a PC and using a USB/RJ45 cable type TCSMCNAM3M002P to connect to the safety controller. It installs with a mounting plate for mounting on rail. Preventa XPSMC configurable safety controller is designed to provide a solution for safety applications requiring conformity to Performance Level PL e/Category 4 EN ISO 13849-1 and SIL3 EN/IEC 61508. The configurable safety controller consists of 6 variants with 16 or 32 digital inputs and 8 digital outputs and communication possibilities of Modbus RTL Serial, Profibus DP and CANopen.
Read more arrow Read less arrow
Specification Value
Height 151.5 mm
[Ith] Conventional Free Air Thermal Current 16 A relay output || 6.5 A static output circuit
Mounting Support mounting plate
Output Thermal Current 4 A for both outputs simultaneously || 6 A for 1 output and 2 A for the other relay output
Power Consumption In W 12 W
Minimum Output Voltage 17 V relay output
Response Time configurable : 20 ms or 30 ms with software XPSMCWIN
Data Format 1 start bit/8 data bits || 1 stop bit even or odd || 2 stop bits without parity || RTU (Remote Terminal Unit) mode
Minimum Output Current 10 mA relay output
Associated Fuse Rating 16 A gL power supply || 4 A gL relay output || 6 A fast blow relay output
[Uimp] Rated Impulse Withstand Voltage 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1
Net Weight 0.84 kg
Output Type 2 relays, 2 NO contacts (4 NO total) || solid state, 6, volt-free
[Ui] Rated Insulation Voltage 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1
Parity even Modbus || no Modbus || odd Modbus
Exchange Size 14 words
Supported Modbus Function 01 8-bit output data/32-bit input data || 02 32-bit input data/8-bit output data || 03 information and errors
Method Of Access slave
Local Signalling 48 LEDs
Number Of Addresses 1-127 CANopen || 1-247 Modbus
Maximum Line Resistance 100 Ohm <2000 m
Input Protection Type external fuse 16 A
Width 74 mm
Depth 153 mm
[Uc] Control Circuit Voltage 28.8 V
Function Of Module dynamic monitoring of hydraulic valves on linear presses || eccentric press || emergency stop monitoring, with or without time delay, 1 or 2-channel wiring || enabling switch monitoring, 2 or 3 contacts || foot switch monitoring || guard monitoring for injection presses and blowing machines || guard monitoring with 1 or 2 limit switches || hydraulic press || magnetic switch monitoring category 4 EN/IEC 61496 || monitoring safety stop at top dead centre on eccentric press category 3 EN 574/ISO 13851 || muting function of light curtains || position selector || safety mat monitoring || safety time delays || shaft/chain breaking monitor || zero speed detection || light curtain monitoring category 4 IEC 61496 || two-hand control category 3 EN 574/ISO 13851
Synchronisation Time Between Inputs depending on configuration selected
Breaking Capacity 2 A 24 V static output circuit || 1.5 A 24 V DC-13)50 ms relay output
Breaking Capacity 180 VA holding AC-15 C300 relay output || 1800 VA inrush AC-15 C300 relay output
Product Certifications UL || TÜV || CSA
[Us] Rated Supply Voltage 24 V DC - 20...20 %
Range Of Product Preventa Safety automation
Standards IEC 60947-5-1 || EN 574/ISO 13851 || EN 1760-1/ISO 13856-1 || IEC 61496-1 || IEC 61508 || EN 954-1/EN/ISO 13849-1 || IEC 60204-1
Number Of Inputs 32
Product Or Component Type configurable safety controller
Safety Module Name XPSMC
Type Of Start configurable
Communication Port Protocol CANopen 1 SUB-D 9-pin male, serial link 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps or 1 Mbps || Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps
Safety Use Category category 4 maximum EN 954-1/EN/ISO 13849-1 || PLE maximum ISO 13849-1 || SIL 3 maximum IEC 61508
Safety Level can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 || can reach SIL 3 IEC 61508
Read more arrow Read less arrow
*New items come with up to 24 month Obso Warranty
Our previously used items and repair options come with 12 months Obso Warranty.


"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
*Same & Next Day Delivery & Collection is available for stock from our UK and NL branches. Next-day delivery collection and 2 day delivery is available for stock sourced from our partners. In 90% of cases, we can deliver faster than the manufacturer’s ETA where required.

Standard options for delivery are also available where required.


"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
We are ISO 9001 accredited so you have peace of mind with your purchase.

What our customers say about us

Trustpilot

1

Step 1

    Part added for enquiry

    2

    Step 2

    Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.

    3

    Step 3

    We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.

    4

    Step 4

    Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.