XPSBAC14AP
safety module, Harmony XPS, estop or guard, connected to supply terminals 24V AC or DC , no inputs, screw
AVAILABLE
GET A QUOTE NOW
| Specification | Value |
|---|---|
| [Us] Rated Supply Voltage | 24 V AC - 15...10 % || 24 V DC - 20...20 % |
| Range Of Product | Harmony Safety Automation |
| Product Or Component Type | safety module |
| Safety Module Name | XPSBAC |
| Connections - Terminals | removable screw terminal block, 0.2...2.5 mm² solid or flexible || removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel |
| Safety Module Application | for emergency stop and protective guard applications |
| Safety Reliability Data | MTTFd > 30 years for normally open relay contact ISO 13849-1 || Dcavg >= 99 % for normally open relay contact ISO 13849-1 || PFHd = 0.95E-09 for normally open relay contact ISO 13849-1 || HFT = 1 for normally open relay contact IEC 62061 || PFHd = 0.95E-09 for normally open relay contact IEC 62061 || SFF > 99% for normally open relay contact IEC 62061 || HFT = 1 for normally open relay contact IEC 61508-1 || PFHd = 0.95E-09 for normally open relay contact IEC 61508-1 || SFF > 99% for normally open relay contact IEC 61508-1 || type = B for normally open relay contact IEC 61508-1 || MTTFd > 30 years for normally closed relay contact ISO 13849-1 || DC > 60 % for normally closed relay contact ISO 13849-1 || PFHd = 0.95E-09 for normally closed relay contact ISO 13849-1 || HFT=0 for normally closed relay contact IEC 62061 || PFHd = 0.95E-09 for normally closed relay contact IEC 62061 || SFF > 60% for normally closed relay contact IEC 62061 || HFT=0 for normally closed relay contact IEC 61508-1 || PFHd = 0.95E-09 for normally closed relay contact IEC 61508-1 || SFF > 60% for normally closed relay contact IEC 61508-1 || type = B for normally closed relay contact IEC 61508-1 |
| Electrical Circuit Type | NC pair |
| Function Of Module | emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches |
| Safety Level | can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay contact ISO 13849-1 || can reach SILCL 1 for normally closed relay contact IEC 62061 || can reach SIL 1 for normally closed relay contact IEC 61508 |
| Terminal Identifier | power supply |
| Number Of Outputs | 0 |
| Height | 100 mm |
| Mounting Support | 35 mm symmetrical DIN rail |
| Minimum Output Voltage | 5 V relay output |
| Response Time | 150 ms at 24 V AC || 80 ms at 24 V DC |
| Minimum Output Current | 10 mA relay output |
| [Ith] Conventional Free Air Thermal Current | 6 A |
| Associated Fuse Rating | 10 A gG NO relay output circuit IEC 60947-1 |
| Local Signalling | LED green power power ON || LED red error error || LED yellow state status || LED yellow start1 start input || LED yellow start2 start input |
| [Uimp] Rated Impulse Withstand Voltage | 4 kV II IEC 60947-1 |
| Net Weight | 0.200 kg |
| Type Of Start | automatic/manual/monitored |
| Number Of Inputs | 0 |
| Input Compatibility | normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 |
| Power Consumption In Va | 3.5 VA 24 V AC 50/60 Hz |
| [Ie] Rated Operational Current | 5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally closed relay contact || 3 A DC-1 for normally closed relay contact || 1 A DC-13 for normally closed relay contact |
| Auxiliary Contact Composition | 4 NO + 1 NC |
| [Ui] Rated Insulation Voltage | 300 V 2)IEC 60947-1 |
| Power Consumption In W | 1.5 W 24 V DC |
| Input Protection Type | internal, electronic |
| Width | 22.5 mm |
| Depth | 120 mm |
| Synchronisation Time Between Inputs | unlimited |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews