TPRSS065

SIL motor starter, TeSys island, 80A at AC-1, 65A at AC-3, 30kW, 40hp, DOL type

AVAILABLE

GET A QUOTE NOW

TeSys island direct SIL starter, 3 poles, 65A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 65A and motors up to 30kW@400V / 40hp@480V. In association with a TPRSM001 module and an external safety device, it can be used for safety related systems conforming to IEC 61508. It provides motor protection functions including thermal overload (setting 3.35-65A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Read more arrow Read less arrow
Specification Value
Mounting Mode horizontal and vertical 35 mm symmetrical DIN rail)
Height 167 mm
Product Certifications CSA || UL || EAC || CCC
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Standards EN/IEC 60947-1 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
Connections - Terminals EverLink BTR screw connectors 1 1-35 mm² AWG 16...AWG 2)rigid || EverLink BTR screw connectors 2 1-25 mm² AWG 16...AWG 4)rigid || EverLink BTR screw connectors 1 1-35 mm² AWG 16...AWG 2)flexible without cable end || EverLink BTR screw connectors 2 1-25 mm² AWG 16...AWG 4)flexible without cable end || EverLink BTR screw connectors 1 1-35 mm² AWG 16...AWG 2)flexible with cable end || EverLink BTR screw connectors 2 1-25 mm² AWG 16...AWG 4)flexible with cable end
Net Weight 1.248 kg
Metering Type time device ON || time device switch ON || number of faults || number of switching cycles || number of device power cycles || average current Iavg || average voltage Vavg || max current Imax || max voltage Vmax || active and reactive power with voltage module || active and reactive energy with voltage module || true power factor with voltage module
Maximum Operating Rate 3600 cyc/mn AC-3
Local Signalling for DS (device status) 1 LED (green/red) || for LS (load status) 1 LED (green/red)
Electrical Durability 1.4 Mcycles 65 A AC-3 440 V || 0.5 Mcycles 80 A AC-1 440 V
Mechanical Durability 6 Mcycles
Safety Function safe stop: category 0 conforming to IEC 60204-1 when associated with a TPRSM module || safe stop: category 1 conforming to IEC 60204-1 when associated with a TPRSM module
Operating Time < 80 ms closing || < 80 ms opening
Width 55 mm
Depth 125 mm
Tightening Torque 5-5 N.m 1-25 mm² hexagonal 4 mm || 8-8 N.m 25-35 mm² hexagonal 4 mm
Protection Type thermal overload protection || motor overheat || overcurrent || undercurrent || jam || long start || stall || rapid cycle lockout || phase sequence || rapid restart lockout || phase reversal || phase loss || phase unbalance || ground current
Safety Level SIL 2 conforming to IEC 61508 in single channel system architecture || SILCL 2 conforming to IEC 62061 in single channel system architecture || PL = d category 2 conforming to ISO 13849-1 in single channel system architecture
Current Consumption 80 mA contactor sealed || 500 mA contactor closing
Power Dissipation In W 20.8 W at Ie AC-3
Power Dissipation Per Pole 6.3 W AC-3 - Ith 65 A || 9.6 W AC-1 - Ith 80 A
Average Impedance 1.5 mOhm - Ith 80 A 50 Hz
Reset remotely or automatically
[Ith] Conventional Free Air Thermal Current 80 A (at 50 °C)
[Uc] Control Circuit Voltage 24 V DC supplied by the bus coupler
Rated Breaking Capacity 1000 A at 440 V conforming to IEC 60947
Product Or Component Type SIL motor starter
Irms Rated Making Capacity 1000 A at 440 V conforming to IEC 60947
Product Name TeSys island
Thermal Overload Class class 5…30
[Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947-1
Range TeSys
Device Presentation direct starter connected to an automation controller through a bus coupler || operational only when connected to a bus coupler
Motor Starter Type direct on line
Utilisation Category AC-1 || AC-2 || AC-3 || AC-4
Function Available upstream voltage presence detection || electrical line and load protection || power and energy monitoring when connected with TPRVM voltage module || safe stop function available when connected with a TPRSM module
[Ie] Rated Operational Current 65 A (at <50 °C) at <= 440 V AC-3 || 80 A (at <50 °C) at <= 440 V AC-1
Overvoltage Category III
Thermal Protection Adjustment Range 3.35-65 A
Product Compatibility TPRBC bus coupler || TPRVM voltage interface module || TPRSM SIL interface module
[Ue] Rated Operational Voltage <= 690 V AC 47...63 Hz
Maximum Horse Power Rating 5 hp at 120 V AC 60 Hz for 1 phase motors || 10 hp at 240 V AC 60 Hz for 1 phase motors || 20 hp at 208 V AC 60 Hz for 3 phase motors || 20 hp at 240 V AC 60 Hz for 3 phase motors || 40 hp at 480 V AC 60 Hz for 3 phase motors || 50 hp at 600 V AC 60 Hz for 3 phase motors
Motor Power Kw 18.5 kW at 230 V 50 Hz (AC-3) || 30 kW at 380...415 V 50 Hz (AC-3) || 30 kW at 440 V 50 Hz (AC-3) || 37 kW at 500 V 50 Hz (AC-3) || 37 kW at 690 V 50 Hz (AC-3)
[Ui] Rated Insulation Voltage 690 V IEC 60947-4-1 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Device Short Name TPRSS
Poles Description 3P 3 NO
[Icw] Rated Short-Time Withstand Current 900 A 40 °C - 1 s || 520 A 40 °C - 10 s || 260 A 40 °C - 1 min || 110 A 40 °C - 10 min
Read more arrow Read less arrow
*New items come with up to 24 month Obso Warranty
Our previously used items and repair options come with 12 months Obso Warranty.


"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
*Same & Next Day Delivery & Collection is available for stock from our UK and NL branches. Next-day delivery collection and 2 day delivery is available for stock sourced from our partners. In 90% of cases, we can deliver faster than the manufacturer’s ETA where required.

Standard options for delivery are also available where required.


"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
We are ISO 9001 accredited so you have peace of mind with your purchase.

What our customers say about us

Trustpilot

1

Step 1

    Part added for enquiry

    2

    Step 2

    Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.

    3

    Step 3

    We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.

    4

    Step 4

    Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.