| Specification | Value |
|---|---|
| Network Frequency | 50/60 Hz |
| Discrete Input Logic | sink or source (positive/negative) |
| Data Backed Up | 256 kB built-in flash memory backup of application and data |
| Exct Time For Event Task | 60 µs response time |
| Input Impedance | 3.4 kOhm discrete input || 100 kOhm analog input || 4.9 kOhm fast input |
| Electrical Connection | removable screw terminal block for inputs || removable screw terminal block for outputs || terminal block, 3 for connecting the 24 V DC power supply || connector, 4 for analogue inputs || mini B USB 2.0 connector for a programming terminal |
| Maximum Cable Distance Between Devices | shielded cable <10 m fast input || unshielded cable <30 m output || unshielded cable <30 m digital input || unshielded cable <1 m analog input |
| Height | 90 mm |
| Discrete Input Voltage | 24 V |
| Inrush Current | 40 A |
| Discrete Input Voltage Type | DC |
| Communication Service | DHCP client || Modbus TCP client || Ethernet/IP adapter || Modbus TCP server || Modbus TCP slave device |
| Port Ethernet | 10BASE-T/100BASE-TX 1 100 m copper cable |
| Maximum Current Per Output Common | 7 A |
| Transmission Rate | 1.2...115.2 kbit/s (115.2 kbit/s by default) 15-15 m RS485 || 1.2...115.2 kbit/s (115.2 kbit/s by default) 3-3 m RS232 || 480 Mbit/s USB |
| Clock Drift | <= 30 s/month 25-25 °C |
| Battery Type | BR2032 or CR2032X lithium non-rechargeable |
| Communication Port Protocol | USB port USB - SoMachine-Network || non isolated serial link Modbus master/slave - RTU/ASCII or SoMachine-Network || Ethernet |
| Protection Type | without protection 5 A |
| Marking | CE |
| Backup Time | 1 year 25 °C by interruption of power supply) |
| Discrete I/O Number | 40 |
| Reset Time | 1 s |
| Regulation Loop | adjustable PID regulator up to 14 simultaneous loops |
| Maximum Number Of I/O Expansion Module | 7 (local I/O-Architecture) || 14 (remote I/O-Architecture) |
| Power Supply Output Current | 0.52-0.52 A 5 V expansion bus || 0.24-0.24 A 24 V expansion bus |
| Net Weight | 0.456 kg |
| Voltage State 0 Guaranteed | <= 5 V input |
| Configurable Filtering Time | 0 ms input || 3 ms input || 12 ms input |
| Output Voltage Limits | 125 V DC || 277 V AC |
| Maximum Size Of Object Areas | 8000 %MW memory words || 255 %TM timers || 512 %KW constant words || 255 %C counters || 512 %M memory bits |
| Memory Capacity | 256 kB user application and data RAM 10000 instructions || 256 kB internal variables RAM |
| Conversion Time | 1 ms per channel + 1 controller cycle time analog input |
| Voltage State 1 Guaranteed | >= 15 V input |
| Control Signal Type | single phase || A/B || pulse/direction |
| Supply Voltage Limits | 85-264 V |
| Integrated Connection Type | USB port mini B USB 2.0 || non isolated serial link serial 1 RJ45 RS232/RS485 || Ethernet RJ45 |
| Execution Time Per Instruction | 0.2 µs Boolean |
| Sensor Power Supply | 24-24 V DC 250 mA supplied by the controller |
| Mechanical Durability | 20000000 cycles relay output |
| Electrical Durability | 100000 cycles AC-12, 120 V, 240 VA, resistive || 100000 cycles AC-12, 240 V, 480 VA, resistive || 300000 cycles AC-12, 120 V, 80 VA, resistive || 300000 cycles AC-12, 240 V, 160 VA, resistive || 100000 cycles AC-15, cos phi = 0.35 , 120 V, 60 VA, inductive || 100000 cycles AC-15, cos phi = 0.35 , 240 V, 120 VA, inductive || 300000 cycles AC-15, cos phi = 0.35 , 120 V, 18 VA, inductive || 300000 cycles AC-15, cos phi = 0.35 , 240 V, 36 VA, inductive || 100000 cycles AC-14, cos phi = 0.7 , 120 V, 120 VA, inductive || 100000 cycles AC-14, cos phi = 0.7 , 240 V, 240 VA, inductive || 300000 cycles AC-14, cos phi = 0.7 , 120 V, 36 VA, inductive || 300000 cycles AC-14, cos phi = 0.7 , 240 V, 72 VA, inductive || 100000 cycles DC-12, 24 V, 48 W, resistive || 300000 cycles DC-12, 24 V, 16 W, resistive || 100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms) || 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms) |
| Absolute Accuracy Error | +/- 1 % of full scale analog input |
| Mounting Support | top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit |
| Local Signalling | for PWR 1 LED (green) || for RUN 1 LED (green) || for module error (ERR) 1 LED (red) || for SD card access (SD) 1 LED (green) || for BAT 1 LED (red) || for I/O state 1 LED per channel (green) || for SL 1 LED (green) || for ACT Ethernet network activity (green) || for Link (Link Status) Ethernet network link (yellow) |
| Response Time | 35 µs turn-off, I2...I5 input || 10 ms turn-on output || 10 ms turn-off output || 5 µs turn-on, I0, I1, I6, I7 fast input || 35 µs turn-on, other terminals input || 5 µs turn-off, I0, I1, I6, I7 fast input || 100 µs turn-off, other terminals input |
| Discrete Input Current | 7 mA discrete input || 5 mA fast input |
| Execution Time For 1 Kinstruction | 0.3 ms event and periodic task |
| Analogue Input Resolution | 10 bits |
| Realtime Clock | with |
| Lsb Value | 10 mV |
| Width | 160 mm |
| Depth | 70 mm |
| Minimum Load | 1 mA 5 V DC relay output |
| Data Storage Equipment | 2 GB SD card optional) |
| Insulation | between input and internal logic 500 V AC || non-insulated between analogue input and internal logic || non-insulated between analogue inputs || between supply and ground 1500 V AC || between sensor power supply and ground 500 V AC || between input and ground 500 V AC || between output and ground 1500 V AC || between supply and internal logic 2300 V AC || between sensor power supply and internal logic 500 V AC || between output and internal logic 2300 V AC || between Ethernet terminal and internal logic 500 V AC || between supply and sensor power supply 2300 V AC |
| Maximum Power Consumption In Va | 70 VA 100...240 V with max number of I/O expansion module || 41 VA 100...240 V without I/O expansion module |
| Supply | serial)serial link supply 5 V, <200 mA |
| Counting Input Number | 4 fast input (HSC mode) 100 kHz 32 bits |
| Permitted Overload On Inputs | +/- 30 V DC 5 min maximum)analog input || +/- 13 V DC permanent)analog input |
| Switching Frequency | 20 switching operations/minute with maximum load |
| Discrete Output Type | relay normally open |
| Range Of Product | Modicon M221 |
| Discrete Output Number | 16 relay |
| Product Or Component Type | logic controller |
| Discrete Output Current | 2 A |
| Discrete Output Voltage | 5...125 V DC || 5...250 V AC |
| Analogue Input Number | 2 0...10 V |
| [Us] Rated Supply Voltage | 100...240 V AC |
| Discrete Input Number | 24 , discrete input IEC 61131-2 Type 1 |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews