SR2B121JD
Schneider Electric
compact smart relay, Zelio Logic SR2 SR3, 12 IO, 12V DC, clock, display
AVAILABLE
GET A QUOTE NOW
- "This Schneider Electric Zelio Logic SR2B compact smart relay / programmable controller uses a supply voltage of 12 volts direct current, has 12 inputs / outputs with screw-clamp terminals, has an integrated clock and LCD display. This compact programmable relay is ideal for management, remote control or monitoring of simple automation systems. It is suitable for both industrial and commercial applications. It has compact form-factor, allowing installation on DIN rail. It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons. Simple ladder programming, adapted for non-specialists. Discovery package, coming with Zelio Soft programming software, the simplest way to learn and use this relay. Built-in EEPROM flash memory for data backup up to 10 years, easy-to-recover after a power shortage or incident. This product meets EN/IEC 61000-4-11, EN/IEC 60068-2-6 Fc, EN/IEC 61000-4-12, EN/IEC 61000-4-2 level 3, EN/IEC 61000-4-5, EN/IEC 61000-4-3, EN/IEC 61000-4-4 level 3, EN/IEC 60068-2-27 Ea and EN/IEC 61000-4-6 level 3 standards. Simple to select, install and program, Zelio Logic is suitable for all your applications. Flexible, it offers you the choice of 2 ranges, compact or modular, extendable and 2 programming languages (FBD or LADDER). Easy to use, Zelio Logic provides a real alternative to solutions based on cabled logic or specific cards."
| Specification | Value |
|---|---|
| Contacts Type And Composition | NO relay output |
| Input Impedance | 14 kOhm IB...IG used as analogue input circuit || 14 kOhm IB...IG used as discrete input circuit || 2.7 kOhm I1...IA and IH...IR discrete input circuit |
| Discrete Input Type | resistive |
| Number Of Outputs | 4 relay |
| Analogue Input Range | 0...10 V || 0...12 V |
| Conversion Error | +/- 5 % 25 °C analogue input circuit || +/- 6.2 % 55 °C analogue input circuit |
| Output Thermal Current | 8 A for all 4 outputs relay output |
| Discrete Input Voltage | 12 V DC |
| Number Or Control Scheme Lines | 0-240 ladder || 0-500 FBD |
| Lsb Value | 39 mV analogue input circuit |
| Backup Time | 10 years 25 °C |
| Clock Drift | 12 min/year 0-55 °C || 6 s/month 25-25 °C |
| Analogue Input Type | common mode |
| Discrete Input Current | 4 mA |
| Current State 1 Guaranteed | >= 2 mA I1...IA and IH...IR discrete input circuit) || >= 0.5 mA IB...IG used as discrete input circuit) |
| Response Time | 10 ms from state 0 to state 1)relay output || 5 ms from state 1 to state 0)relay output |
| Clock | with |
| Power Dissipation In W | 1.5 W without extension |
| Local Display | with |
| Net Weight | 0.25 kg |
| [Uimp] Rated Impulse Withstand Voltage | 4 kV EN/IEC 60947-1 and EN/IEC 60664-1 |
| Voltage State 0 Guaranteed | <= 3 V IB...IG used as discrete input circuit || <= 2.4 V I1...IA and IH...IR discrete input circuit |
| Output Voltage Limits | 24...250 V AC relay output) || 5...30 V DC relay output) |
| Conversion Time | smart relay cycle time analogue input circuit |
| Electrical Durability | AC-12 500000 cycles 230 V, 1.5 A relay output IEC 60947-5-1 || AC-15 500000 cycles 230 V, 0.9 A relay output IEC 60947-5-1 || DC-12 500000 cycles 24 V, 1.5 A relay output IEC 60947-5-1 || DC-13 500000 cycles 24 V, 0.6 A relay output IEC 60947-5-1 |
| Connections - Terminals | screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid || screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid || screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end |
| Analogue Input Number | 4 |
| Voltage State 1 Guaranteed | >= 7 V IB...IG used as discrete input circuit || >= 5.6 V I1...IA and IH...IR discrete input circuit |
| Input Compatibility | 3-wire proximity sensors PNP discrete input |
| Current State 0 Guaranteed | <= 0.2 mA IB...IG used as discrete input circuit) || <= 0.9 mA I1...IA and IH...IR discrete input circuit) |
| Supply Voltage Limits | 10.4-14.4 V |
| Operating Distance | 10 m between stations, with screened cable (sensor not isolated) analogue input circuit |
| Overvoltage Category | III IEC 60664-1 |
| Mechanical Durability | 10000000 cycles relay output |
| Maximum Supply Current | 120 mA without extension) |
| Tightening Torque | 0.5 N.m |
| Switching Capacity In Ma | >= 10 mA 12 V relay output) |
| Analogue Input Resolution | 8 bits at maximum voltage |
| Operating Rate In Hz | 0.1 Hz at Ie)relay output || 10 Hz no load)relay output |
| Counting Frequency | 1 kHz discrete input |
| Discrete Input Number | 8 IEC 61131-2 Type 1 |
| Cycle Time | 6-90 ms |
| Reverse Polarity Protection | with |
| Maximum Permissible Voltage | 14.4 V analogue input circuit |
| Repeat Accuracy | +/- 2 % 55 °C analogue input circuit |
| [Us] Rated Supply Voltage | 12 V DC |
| Checks | program memory on each power up |
| Range Of Product | Zelio Logic |
| Product Or Component Type | compact smart relay |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews