REL52128
Schneider Electric
Easergy P3F30 3CT 2Io ringlug 4VT 6DI 10DO 110-230V DI110V 3BIO 6ARC RS485 RJ45 ANSI
AVAILABLE
GET A QUOTE NOW
-
| Specification | Value |
|---|---|
| Monitoring Function | trip circuit supervision 74 || circuit breaker monitoring || relay self-monitoring |
| Analogue Output Number | 0 |
| Input Type | 3 1/5 A CT phase current || 1 5/1 A CT residual current || 1 1/0.2 A CT residual current || 4 100 V/110 V VT voltage |
| Range Of Product | Easergy P3 |
| Connections - Terminals | screw removable (digital input/output) || ring lugs fixed (current transformer) || pin removable (voltage transformer) |
| Network And Machine Diagnosis Type | event recording || disturbance recording || tripping context |
| Device Mounting | flush |
| Control Type | switchgear control and monitoring || programmable switchgear interlocking || local control on single-line diagram || local control with I/O keys || local/remote control || 2 function keys || mobile application with Easergy SmartApp || web-server |
| Number Of Outputs | 10 DO || 1 watchdog |
| Digital Input Number | 6.0 |
| Setting | 4 |
| Protection Type | fault locator 21FL || synchro-check 25 || undervoltage 27 || directional active underpower 37P || broken conductor 46BC || thermal overload protection 49 || earth fault overcurrent 50N/51N || phase overcurrent 50/51 || breaker failure 50BF || switch ON to fault (SOTF) || capacitor bank unbalance 51C || voltage-restrained overcurrent 51V || capacitor overvoltage 59C || overvoltage 59 || earth fault overvoltage 59N || directional phase overcurrent 67 || directional earth fault 67N || transient earth fault 67NI || H2 detection 68H2 || H5 detection 68H5 || recloser 79 || underfrequency 81/81N || rate of change of frequency 81R || lockout relay 86 || programmable stages 99 || programmable curve || cold load pick-up |
| Relay Application | feeder |
| Integrated Connection Type | front USB port 1 || rear RJ45 1 || rear RS485 1 |
| Cybersecurity | password protection || port hardening |
| Communication Port Protocol | IEC 61850 ed. 1 || IEC 61850 ed. 2 || IEC 60870-5-101 || DNP3 TCP || Modbus TCP || EtherNet/IP || IEC 60870-5-103 || DNP3 || Modbus RTU || DeviceNet || SPAbus |
| Product Or Component Type | protection relay |
| Switchgear Diagnosis Type | CT/VT supervision || trip circuit supervision TCS |
| Arc Flash Protection | yes |
| Single Line Diagram | 3 controlled + 5 displayed |
| Type Of Measurement | current 3-phase || current zero sequence || current positive sequence || current negative sequence || current ratio of negative and positive || voltage phase to earth || voltage phase to phase || voltage zero sequence || voltage positive sequence || voltage negative sequence || voltage ratio of negative and positive || short circuit fault reactance || fault location current || earth fault reactance || frequency || active power || RMS active power || reactive power || RMS reactive power || apparent power || RMS apparent power || active energy || reactive energy || cos φ || tan φ || power angle || power factor || voltage phasor diagram view || current phasor diagram view || current 2nd, 15th harmonics with THD || voltage 2nd, 15th harmonics with THD || condition monitoring CB wear || voltage interruption |
| Device Short Name | P3F30-CBGAD-DA1FA-BBAAB |
| [Us] Rated Supply Voltage | 48...230 V AC/DC |
| Number Of Key | 2 customizable |
| Operating Threshold | 110 V AC/DC |
| Time Synchronisation Protocol | SNTP |
| Width | 270 mm |
| Height | 176 mm |
| Display Type | LCD 128 x 128 pixels with single line diagram || LCD 128 x 128 pixels with ANSI symbols |
| Net Weight | 4.2 kg maximum |
| Local Signalling | 2 LEDs || 16 LEDs programmable |
| Depth | 230 mm |
| Web Server | embedded HTTP server |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews