RC816D400SL
Schneider Electric
Meter mains, Homeline, CSED, ringless socket, 400A, surface mount, maximum 8 spaces, 16 circuits, Class 320 with lever bypass
AVAILABLE
GET A QUOTE NOW
- "Square D\u2122 Meter Mains are single phase power distribution panels used in residential applications where local codes require service disconnects to be located outside the dwelling. The meter socket supports a standard utility meter and a main disconnect breaker which provides a time and space saving solution for contractors and installers. Meter mains are surface mount with provisions. This is for the field installation of the service disconnect(s) that feed devices downstream. Interior subfeed load centers are typically used with these. This CSED is a Homeline ringless type with horn bypass, and combination overhead/underground feed. With a current rating of 400A, this product has a short circuit current rating of 22kA. Single main service disconnects option is also available. Devices meet the Electric Utility Service Equipment Requirements Committee (EUSERC) standards, Federal Specifications W-P-115C for government housing."
| Specification | Value |
|---|---|
| Height | 32.68 in |
| Tightening Torque | main lugs 500 lb.in, aluminium/copper || main lugs 500 lb.in, AWG 4/0...600 kcmil, aluminium/copper || service ground 50 lb.in, AWG 14...AWG 1/0, copper || service ground 50 lb.in, AWG 12...AWG 1/0, aluminium || branch lugs 50 lb.in, AWG 3...AWG 2/0, aluminium/copper || branch lugs 45 lb.in, AWG 6...AWG 4, aluminium/copper || branch lugs 40 lb.in, AWG 8, aluminium/copper || branch lugs 35 lb.in, AWG 14...AWG 10, copper || branch lugs 35 lb.in, AWG 12...AWG 10, aluminium || Cover 10 lb.in |
| Branch Circuit Breaker Rated Current | 30 A || 50 A || 200 A |
| Bypass Type | class 320 lever bypass |
| Service Feed Location | OH || UG |
| Bus Rated Current | 200.0 A |
| Electrical Connection | feed-thru lugs |
| Number Of Circuits | 16 |
| Number Of Spaces | 8 |
| Number Of Tandem Circuit Breakers | 8 |
| Meter Socket Type | ringless |
| Service Disconnect Rated Current | 200 A |
| Line Rated Current | 400 A |
| Awg Gauge | AWG 4...600 kcmil aluminium/copper) || AWG 1/0...350 kcmil 2 aluminium/copper) |
| Width | 28 in |
| Depth | 7.89 in |
| Network Number Of Phases | 1 |
| Device Composition | service disconnect (factory installed) |
| Device Mounting | surface |
| Range Of Product | Homeline |
| Product Or Component Type | Meter Mains |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews