LTMR08MFM
Motor controller, TeSys T, Motor Management, Modbus, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240VAC
AVAILABLE
GET A QUOTE NOW
| Specification | Value |
|---|---|
| Contacts Type And Composition | 1 NO + 1 NC fault signal || 3 NO |
| Height | 61 mm |
| Connection Pitch | 5.08 mm |
| Permissible Power | 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output) |
| Network And Machine Diagnosis Type | event recording || fault recording || waiting time after overload tripping || running hours counter/operating time || phase fault and earth fault trip counters || trip context information || starting current and time || motor control command recording || remaining operating time before overload tripping || trip history information |
| Pollution Degree | 3 |
| Logic Input Number | 6 |
| Maximum Operating Rate | 1800 cyc/h |
| Connections - Terminals | control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end |
| Input Current | 3.1 mA 100 V || 7.5 mA 240 V |
| Current State 1 Guaranteed | logic input 79...264 V >= 2 mA 25 ms |
| Net Weight | 0.53 kg |
| [Uimp] Rated Impulse Withstand Voltage | 4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1 |
| Associated Fuse Rating | 4 A gG output || 0.5 A gG control circuit |
| Electromagnetic Compatibility | electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 |
| Measurement Accuracy | 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power |
| Current State 0 Guaranteed | logic input 0...40 V <= 15 mA 25 ms |
| [Ui] Rated Insulation Voltage | 690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508 |
| Short-Circuit Withstand | 100 kA conforming to EN/IEC 60947-4-1 |
| Compatibility Code | LTMR |
| Protection Type | reverse polarity protection || locked rotor || earth-leakage protection || thermal overload protection || phase failure || overload || thermal protection || power factor variation || load fluctuation || phase unbalance || overload (long time) |
| Web Services | web server |
| Width | 91 mm |
| Load Current | 5 A 250 V AC logic output || 5 A 30 V DC logic output |
| Tightening Torque | control circuit 0.5-0.6 N.m flat 3 mm |
| Overvoltage Category | III |
| Depth | 122.5 mm |
| Maximum Operating Frequency | 2 Hz |
| Metering Type | average current Iavg || temperature || earth-fault current || imbalance current || phase current I1, I2, I3 RMS |
| Product Or Component Type | motor controller |
| Product Name | TeSys T |
| Measurement Current | 0.4-8 A |
| Range | TeSys |
| Current Consumption | 8...62.8 mA |
| [Us] Rated Supply Voltage | 100...240 V AC 50/60 Hz |
| Communication Port Protocol | Modbus |
| Bus Type | Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, RJ45 2 shielded twisted pairs || Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, terminal block 2 shielded twisted pairs |
| Supply Voltage Limits | 93.5-264 V AC |
| Device Application | equipment monitoring and control |
| Device Short Name | LTMR |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews