LC3D115P7A64
Schneider Electric
Star delta starter, TeSys Deca, 3x3P(3NO), 115A, 230V AC coil, screw clamp terminal
AVAILABLE
GET A QUOTE NOW
-
| Specification | Value |
|---|---|
| Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact |
| Minimum Switching Current | 5 mA for signalling circuit |
| Height | 555 mm |
| Control Circuit Voltage Limits | drop-out: 0.3...0.5 Uc at 50/60 Hz (at <55 °C) || operational: 0.8...1.15 Uc at 50/60 Hz (at <55 °C) |
| Starting Time | 30 s |
| Net Weight | 12.1 kg |
| Inrush Power In Va | 280-350 VA 60 Hz cos phi 0.8 (at 20 °C) || 280-350 VA 50 Hz cos phi 0.8 (at 20 °C) |
| Connections - Terminals | power circuit: connector 1 10-120 mm² - cable stiffness: flexible without cable end || power circuit: connector 2 10-50 mm² - cable stiffness: flexible without cable end || power circuit: connector 1 10-120 mm² - cable stiffness: flexible with cable end || power circuit: connector 2 10-50 mm² - cable stiffness: flexible with cable end || power circuit: connector 1 10-120 mm² - cable stiffness: solid without cable end || power circuit: connector 2 10-50 mm² - cable stiffness: solid without cable end || control circuit: connector 1 1-2.5 mm² - cable stiffness: flexible without cable end || control circuit: connector 2 1-2.5 mm² - cable stiffness: flexible without cable end || control circuit: connector 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: connector 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: connector 1 1-2.5 mm² - cable stiffness: solid without cable end || control circuit: connector 2 1-2.5 mm² - cable stiffness: solid without cable end |
| Coil Technology | without built-in suppressor module |
| Maximum Operating Rate | 30 cyc/h 60 °C |
| Signalling Circuit Frequency | 25...400 Hz |
| Tightening Torque | power circuit 12 N.m connector flat Ø 6...8 mm || control circuit 1.2 N.m connector flat Ø 6 mm || control circuit 1.2 N.m connector Philips No 2 |
| Mechanical Durability | 8 Mcycles |
| Auxiliary Contacts Type | mechanically linked IEC 60947-5-1 3 x 1 NO + 1 NC || mirror contact IEC 60947-4-1 3 x 1 NC |
| Hold-In Power Consumption In Va | 2-18 VA 60 Hz cos phi 0.3 (at 20 °C) || 2-18 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Switching Voltage | 17 V signalling circuit |
| Width | 450 mm |
| Depth | 205 mm |
| Heat Dissipation | 3-8 W 50/60 Hz |
| Product Certifications | CSA || BV || GL || CCC || GOST || UL || DNV || LROS (Lloyds register of shipping) || RINA |
| Interlocking Type | mechanical |
| [Uc] Control Circuit Voltage | 230 V AC 50/60 Hz |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hz |
| Standards | IEC 60947-5-1 || CSA C22.2 No 14 || EN 60947-5-1 || UL 508 || EN 60947-4-1 || IEC 60947-4-1 |
| Pole Contact Composition | 3 x 3 NO |
| Mounting Support | plate |
| Control Circuit Type | AC 50/60 Hz |
| Contactor Application | motor control |
| Product Or Component Type | star delta starter |
| Product Name | TeSys Deca |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947 |
| Range | TeSys |
| Device Presentation | pre-wired |
| Utilisation Category | AC-3 |
| [Ie] Rated Operational Current | 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit |
| Auxiliary Contact Composition | 1 NC KM2 line contactor || 1 NO KM3 delta contactor |
| Electrical Durability | 0.95 Mcycles 115 A AC-3 <= 440 V |
| Overvoltage Category | III |
| Motor Power Kw | 110 kW 380/400 V AC 50/60 Hz || 110 kW 415 V AC 50/60 Hz || 110 kW 440 V AC 50/60 Hz || 63 kW 220/230 V AC 50/60 Hz |
| [Ui] Rated Insulation Voltage | power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 600 V CSA || signalling circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || signalling circuit 1000 V IEC 60947-1 |
| Device Short Name | LC3D |
| Poles Description | 3 x 3P |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews