| Specification | Value |
|---|---|
| Control Circuit Voltage Limits | 0.3...0.6 Uc -40-55 °C drop-out AC 50 Hz || 0.85...1.1 Uc -40-55 °C operational AC 50 Hz |
| Inrush Power In Va | 200-200 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Coil Technology | without built-in suppressor module |
| Hold-In Power Consumption In Va | 20-20 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat Dissipation | 6-10 W 50 Hz |
| Product Certifications | UL || CSA || RINA || CCC || DNV-GL || LROS (Lloyds register of shipping) || BV || UKCA || EAC || CB |
| Interlocking Type | mechanical |
| [Uc] Control Circuit Voltage | 220 V AC 50 Hz |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC |
| Power Dissipation Per Pole | 12.5 W AC-1 |
| Average Impedance | 0.8 mOhm - Ith 125 A 50 Hz for power circuit |
| [Ith] Conventional Free Air Thermal Current | 125 A (at 60 °C) for power circuit |
| Mounting Support | plate || rail |
| Control Circuit Type | AC 50 Hz |
| Standards | CSA C22.2 No 60947-4-1 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4 |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Contactor Application | resistive load |
| Rated Breaking Capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
| Product Or Component Type | changeover contactor |
| Irms Rated Making Capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
| Product Name | TeSys Deca |
| Associated Fuse Rating | 200 A gG at <= 690 V coordination type 1 for power circuit || 160 A gG at <= 690 V coordination type 2 for power circuit |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947 |
| Connections - Terminals | control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid || control circuit screw clamp terminals 2 1-4 mm²solid || control circuit screw clamp terminals 1 1-2.5 mm²flexible with cable end || power circuit connector 1 4-50 mm²flexible without cable end || power circuit connector 2 4-25 mm²flexible without cable end || power circuit connector 1 4-50 mm²flexible with cable end || power circuit connector 2 4-16 mm²flexible with cable end || power circuit connector 1 4-50 mm²solid || power circuit connector 2 4-25 mm²solid |
| Range | TeSys |
| Pole Contact Composition | 4 NO |
| Device Presentation | preassembled, with prewired power connections |
| Utilisation Category | AC-1 || AC-3 || AC-3e || AC-4 |
| [Ie] Rated Operational Current | 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit || 55 A (at <60 °C) at <= 400 V AC AC-4 for power circuit |
| Maximum Operating Rate | 3600 cyc/h 60 °C |
| Tightening Torque | control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector flat Ø 6 to Ø 8 mm || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2 |
| Electrical Durability | 0.8 Mcycles 125 A AC-1 <= 690 V |
| Mechanical Durability | 10 Mcycles |
| Poles Description | 4P |
| Operating Time | 20...35 ms closing || 6...20 ms opening |
| Overvoltage Category | III |
| [Ui] Rated Insulation Voltage | power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 |
| Device Short Name | LC2D |
| [Icw] Rated Short-Time Withstand Current | 135 A 40 °C - 10 min for power circuit || 320 A 40 °C - 1 min for power circuit || 640 A 40 °C - 10 s for power circuit || 990 A 40 °C - 1 s for power circuit |
| Protective Cover | without |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews