  • "TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 9A reversing inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 2HP at 200 to 208VAC, 2HP at 240VAC, 5HP at 480VAC and 7.5HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 1HP at 240VAC single phase. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Pressure wire connectors are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 3.54 inches wide and 3.39 inches deep. It weighs 1.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product."
Read more arrow Read less arrow
Specification Value
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Minimum Switching Current 5 mA for signalling circuit
Control Circuit Voltage Limits 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60 °C operational AC 50 Hz || 0.85...1.1 Uc -40-60 °C operational AC 60 Hz || 1...1.1 Uc 60-70 °C operational AC 50/60 Hz
Insulation Resistance > 10 MOhm for signalling circuit
Inrush Power In Va 70-70 VA 60 Hz cos phi 0.75 (at 20 °C) || 70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
Coil Technology without built-in suppressor module
Minimum Switching Voltage 17 V for signalling circuit
Signalling Circuit Frequency 25...400 Hz
Auxiliary Contacts Type mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Hold-In Power Consumption In Va 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C) || 7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat Dissipation 2-3 W 50/60 Hz
Product Certifications DNV || CSA || CCC || UL || GL || LROS (Lloyds register of shipping) || BV || RINA || GOST || UKCA
Interlocking Type electrical and mechanical
[Uc] Control Circuit Voltage 120 V AC 50/60 Hz
[Ue] Rated Operational Voltage power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Power Dissipation Per Pole 0.2 W AC-3 || 1.56 W AC-1
Average Impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit
Auxiliary Contact Composition 1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current 10 A (at 60 °C) for signalling circuit || 25 A (at 60 °C) for power circuit
Mounting Support rail || plate
Control Circuit Type AC 50/60 Hz
Standards CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Application resistive load || motor control
Rated Breaking Capacity 250 A at 440 V for power circuit conforming to IEC 60947
Product Or Component Type reversing contactor
Irms Rated Making Capacity 250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1
Product Name TeSys D || TeSys Deca
Associated Fuse Rating 25 A gG at <= 690 V coordination type 1 for power circuit || 20 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for signalling circuit conforming to IEC 60947-5-1
[Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
Connections - Terminals power circuit screw clamp terminals 1 1-4 mm²flexible without cable end || power circuit screw clamp terminals 2 1-4 mm²flexible without cable end || power circuit screw clamp terminals 1 1-4 mm²flexible with cable end || power circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || power circuit screw clamp terminals 1 1-4 mm²solid || power circuit screw clamp terminals 2 1-4 mm²solid || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid || control circuit screw clamp terminals 2 1-4 mm²solid
Range TeSys || TeSys Deca
Pole Contact Composition 3 NO
Device Presentation preassembled with reversing power busbar
Utilisation Category AC-3 || AC-1
[Ie] Rated Operational Current 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Tightening Torque power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 2.5 N.m screw clamp terminals pozidriv No 2
Electrical Durability 0.6 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 9 A AC-3 <= 440 V
Mechanical Durability 15 Mcycles
Poles Description 3P
Operating Time 12...22 ms closing || 4...19 ms opening
Overvoltage Category III
Motor Power Kw 2.2 kW at 220...230 V AC 50 Hz || 4 kW at 380...400 V AC 50 Hz || 4 kW at 415...440 V AC 50 Hz || 5.5 kW at 500 V AC 50 Hz || 5.5 kW at 660...690 V AC 50 Hz
Maximum Horse Power Rating 0.5 hp at 115 V AC 60 Hz for 1 phase motors || 1 hp at 230/240 V AC 60 Hz for 1 phase motors || 2 hp at 200/208 V AC 60 Hz for 3 phase motors || 2 hp at 230/240 V AC 60 Hz for 3 phase motors || 5 hp at 460/480 V AC 60 Hz for 3 phase motors || 7.5 hp at 575/600 V AC 60 Hz for 3 phase motors
[Ui] Rated Insulation Voltage power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL
Device Short Name LC2D
[Icw] Rated Short-Time Withstand Current 30 A 40 °C - 10 min for power circuit || 61 A 40 °C - 1 min for power circuit || 105 A 40 °C - 10 s for power circuit || 210 A 40 °C - 1 s for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit
Protective Cover with
Read more arrow Read less arrow
*New items come with up to 24 month Obso Warranty
Our previously used items and repair options come with 12 months Obso Warranty.


"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
*Same & Next Day Delivery & Collection is available for stock from our UK and NL branches. Next-day delivery collection and 2 day delivery is available for stock sourced from our partners. In 90% of cases, we can deliver faster than the manufacturer’s ETA where required.

Standard options for delivery are also available where required.


"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
We are ISO 9001 accredited so you have peace of mind with your purchase.

What our customers say about us

Trustpilot

1

Step 1

    Part added for enquiry

    2

    Step 2

    Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.

    3

    Step 3

    We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.

    4

    Step 4

    Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.