LC1F7804
Contactor body, TeSys F, 4P(4NO), AC-1, <=440V 1600A without coil
AVAILABLE
GET A QUOTE NOW
-
| Specification | Value |
|---|---|
| Product Certifications | UL || LROS (Lloyds register of shipping) || RINA || DNV || CCC || BV || CB || ABS || UKCA |
| Power Dissipation Per Pole | 250 W AC-1 |
| Average Impedance | 0.1 mOhm - Ith 1600 A 50 Hz |
| Control Circuit Voltage Limits | operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil || drop-out: 0.2...0.4 Uc AC 40...400 Hz with LX1/LX9 coil || operational: 0.85...1.1 Uc DC with LX4 coil || drop-out: 0.2...0.4 Uc DC with LX4 coil |
| [Ith] Conventional Free Air Thermal Current | 1600 A (at 40 °C) |
| Standards | IEC 60947-1 || IEC 60947-4-1 || EN 60947-1 || JIS C8201-4-1 || EN 60947-4-1 |
| [Uc] Control Circuit Voltage | 110...500 V AC 40...400 Hz with LX1/LX9 coil || 48...440 V DC with LX4 coil |
| Mounting Support | plate |
| Rated Breaking Capacity | 6240 A conforming to IEC 60947-4-1 |
| Irms Rated Making Capacity | 7800 A AC conforming to IEC 60947-4-1 |
| Associated Fuse Rating | 800 A aM at <= 440 V || 1600 A gG at <= 440 V |
| [Uimp] Rated Impulse Withstand Voltage | 8 kV |
| Connections - Terminals | power circuit bar 2 100 x 5 mm || power circuit bolted connection || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm² || control circuit screw clamp terminals 2 1-4 mm² |
| Inrush Power In Va | 1900-2300 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 1960-2420 VA (at 20 °C)with LX4 coil |
| Maximum Operating Rate | 600 cyc/h 55 °C |
| Operating Time | 40...80 ms closing with LX1/LX9 coil || 130...230 ms opening with LX1/LX9 coil || 70...80 ms closing with LX4 coil || 100...130 ms opening with LX4 coil |
| Tightening Torque | power circuit 58 N.m || control circuit 1.2 N.m |
| Mechanical Durability | 5 Mcycles |
| Compatibility Code | LC1F |
| Hold-In Power Consumption In Va | 44-55 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil || 42-52 VA (at 20 °C)with LX4 coil |
| Overvoltage Category | III |
| [Ui] Rated Insulation Voltage | 1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C |
| [Icw] Rated Short-Time Withstand Current | 3000 A 40 °C - 3 min || 6250 A 40 °C - 10 s || 5600 A 40 °C - 30 s || 4600 A 40 °C - 1 min || 2200 A 40 °C - 10 min |
| Heat Dissipation | 22-22 W |
| [Ue] Rated Operational Voltage | <= 1000 V AC 50/60 Hz || <= 460 V DC |
| Contactor Application | resistive load |
| Product Or Component Type | contactor |
| Product Name | TeSys F |
| Range | TeSys |
| Pole Contact Composition | 4 NO |
| [Ie] Rated Operational Current | 1600 A 40 °C) <= 440 V AC AC-1 |
| Utilisation Category | AC-1 |
| Poles Description | 4P |
| Device Short Name | LC1F |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews