LC1D40A3BD
IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
AVAILABLE
GET A QUOTE NOW
| Specification | Value |
|---|---|
| Non-Overlap Time | 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact |
| Minimum Switching Current | 5 mA for signalling circuit |
| Power Dissipation Per Pole | 2.4 W AC-3 || 5.4 W AC-1 || 2.4 W AC-3e |
| Average Impedance | 1.5 mOhm - Ith 60 A 50 Hz for power circuit |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| [Ith] Conventional Free Air Thermal Current | 10 A (at 60 °C) for signalling circuit || 60 A (at 60 °C) for power circuit |
| Control Circuit Voltage Limits | 0.1...0.3 Uc -40-70 °C drop-out DC || 0.75...1.25 Uc -40-60 °C operational DC || 1...1.25 Uc 60-70 °C operational DC |
| Mounting Support | plate || rail |
| Contact Compatibility | M4 |
| Control Circuit Type | DC standard |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Pollution Degree | 3 |
| Hold-In Power Consumption In W | 7.4-7.4 W 20 °C |
| Insulation Resistance | > 10 MOhm for signalling circuit |
| Rated Breaking Capacity | 800 A at 440 V for power circuit conforming to IEC 60947 |
| Irms Rated Making Capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947 |
| Associated Fuse Rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
| Pole Contact Composition | 3 NO |
| Connections - Terminals | control circuit: spring terminals 1 0.75-2.5 mm² - cable stiffness: flexible without cable end || control circuit: spring terminals 2 0.75-2.5 mm² - cable stiffness: flexible without cable end || power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: flexible without cable end || power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: flexible without cable end || power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: flexible with cable end || power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: flexible with cable end || power circuit: EverLink BTR screw connectors 1 1-35 mm² - cable stiffness: solid without cable end || power circuit: EverLink BTR screw connectors 2 1-25 mm² - cable stiffness: solid without cable end |
| Coil Technology | built-in bidirectional peak limiting diode suppressor |
| Time Constant | 34 ms |
| Operating Time | 42.5...57.5 ms closing || 16...24 ms opening |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Maximum Operating Rate | 3600 cyc/h 60 °C |
| Signalling Circuit Frequency | 25...400 Hz |
| Tightening Torque | power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connectors 0.75-25 mm² hexagonal 4 mm || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 2.5 N.m screw clamp terminals pozidriv No 2 |
| Electrical Durability | 0.7 Mcycles 60 A AC-1 <= 440 V || 1.5 Mcycles 40 A AC-3 <= 440 V || 1.5 Mcycles 40 A AC-3e <= 440 V |
| Mechanical Durability | 10 Mcycles |
| Inrush Power In W | 19-19 W 20 °C) |
| Auxiliary Contacts Type | mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1 |
| Compatibility Code | LC1D |
| Overvoltage Category | III |
| Maximum Horse Power Rating | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 30 hp at 575/600 V AC 50/60 Hz for 3 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 3 hp at 115 V AC 50/60 Hz for 1 phase motors || 30 hp at 460/480 V AC 50/60 Hz for 3 phase motors |
| Motor Power Kw | 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 11 kW at 220...230 V AC 50/60 Hz (AC-3) || 22 kW at 415...440 V AC 50/60 Hz (AC-3) || 22 kW at 500 V AC 50/60 Hz (AC-3) || 30 kW at 660...690 V AC 50/60 Hz (AC-3) || 9 kW at 400 V AC 50/60 Hz (AC-4) || 18.5 kW at 380...400 V AC 50/60 Hz (AC-3e) || 11 kW at 220...230 V AC 50/60 Hz (AC-3e) || 22 kW at 415...440 V AC 50/60 Hz (AC-3e) || 22 kW at 500 V AC 50/60 Hz (AC-3e) || 30 kW at 660...690 V AC 50/60 Hz (AC-3e) |
| [Ui] Rated Insulation Voltage | power circuit 600 V CSA || power circuit 600 V UL || signalling circuit 690 V IEC 60947-1 || signalling circuit 600 V CSA || signalling circuit 600 V UL || power circuit 690 V IEC 60947-4-1 |
| [Icw] Rated Short-Time Withstand Current | 320 A 40 °C - 10 s for power circuit || 720 A 40 °C - 1 s for power circuit || 72 A 40 °C - 10 min for power circuit || 165 A 40 °C - 1 min for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit |
| Protective Cover | with |
| [Uc] Control Circuit Voltage | 24 V DC |
| [Ue] Rated Operational Voltage | power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC |
| Range Of Product | TeSys Deca |
| Contactor Application | motor control || resistive load |
| Product Or Component Type | contactor |
| Range | TeSys || TeSys Deca |
| Utilisation Category | AC-4 || AC-1 || AC-3 || AC-3e |
| [Ie] Rated Operational Current | 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit || 40 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| Poles Description | 3P |
| Device Short Name | LC1D |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews