EXN150T6H
Schneider Electric
Transformer, dry type, DOE 2016, 150kVA, 3 phase, 480V delta primary, 240V delta secondary, 22M, 150C rise
AVAILABLE
GET A QUOTE NOW
- "EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 150kVA, 480V primary (three wire), 240V secondary (three wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer\u2019s DOE 2016 and NRCan efficiency is a minimum of 98.83% at 35% loading and 75\u00b0C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of 1/2 inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values."
| Specification | Value |
|---|---|
| Transformer Type | energy efficient |
| Range Of Product | Square D |
| Product Or Component Type | transformer |
| Device Application | low voltage electrical distribution |
| Device Short Name | DOE 2016 |
| Tap Loss | 306 no load (core loss) || 2721 load loss (coil loss) |
| Network Frequency | 60 Hz |
| Primary Voltage | 480 V delta |
| Percentage Impedance Voltage | 3.08 % |
| Percentage Reactance | 2.57 % |
| Noise Level | 47 dB || 3 dB NEMA ST-20 |
| Height | 1031 mm |
| Number Of Mounting Holes | 4 Ø: 13 mm |
| [Uimp] Rated Impulse Withstand Voltage | 10 kV |
| Type Of Cooling | natural convection |
| Primary Operational Current | 180.42-180.42 A 360.84 A 150 kVA |
| Efficiency | 98.91 % at 35 % load factor , 75.0 °C |
| Mounting Support | floor || floor, with 7400FMB || ceiling, with 7400CMB22M |
| Temperature Rise | 150 °C || 220 °C insulated |
| Degree Of Protection | UL type 2 || UL type 3R, with 7400WS22M |
| Number Of Tap-Offs | 2 2.5 % FCAN || 4 2.5 % FCBN |
| X/R Ratio | 1.66 |
| Continuous Thermal Current Rating Factor | 1302 16.6 % || 1624 25 % || 3365 50 % || 6267 75 % || 10329 100 % |
| Width | 855 mm |
| Depth | 827 mm |
| Inrush Current | 2053 A |
| Rated Operational Power In Va | 150 kVA |
| Electrical Connection | 4 Hole Nema Pad secondary 11.1 mm || 2 Hole Nema Pad primary 11.1 mm |
| Phase | 3 phase |
| Material | aluminium |
| Net Weight | 456.77 kg |
| Secondary Voltage | 240 V delta |
| Box Number | 22M |
| [Ipk] Rated Peak Withstand Current | 11.72 kA |
Our previously used items and repair options come with 12 months Obso Warranty.
"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
Standard options for delivery are also available where required.
"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
1
Step 1
Part added for enquiry
2
Step 2
Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.
3
Step 3
We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.
4
Step 4
Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.
Google Reviews