  • "Easy TeSys DPE IEC contactor, 3 poles (3NO), for motor control applications up to 65A/690V AC-3 (40HP@480V). It provides a 24V DC coil, 1NO built-in auxiliary contacts, connection by screw clamp terminals. Compact (55mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh)."
Read more arrow Read less arrow
Specification Value
Minimum Switching Current 5 mA for signalling circuit
[Ue] Rated Operational Voltage power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Height 122 mm
Power Dissipation Per Pole 9.6 W AC-1 || 6.3 W AC-3
Average Impedance 1.5 mOhm - Ith 80 A 50 Hz for power circuit
Control Circuit Voltage Limits drop-out: 0.1...0.3 Uc (at <60 °C) || operational: 0.75...1.25 Uc (at <60 °C)
[Ith] Conventional Free Air Thermal Current 10 A (at 60 °C) for signalling circuit || 60 A (at 60 °C) for power circuit
Mounting Support rail || plate
Control Circuit Type DC 50/60 Hz
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Hold-In Power Consumption In W 7.4-7.4 W 20 °C
Insulation Resistance > 10 MOhm for signalling circuit
Rated Breaking Capacity 800 A at 440 V for power circuit conforming to IEC 60947
Irms Rated Making Capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1 || 250 A DC for signalling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
Associated Fuse Rating 10 A gG for signalling circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit || 125 A gG at <= 690 V coordination type 2 for power circuit
Connections - Terminals power circuit: screw connection 1 2.5-25 mm² - cable stiffness: flexible without cable end || power circuit: screw connection 2 2.5-16 mm² - cable stiffness: flexible without cable end || power circuit: screw connection 1 2.5-25 mm² - cable stiffness: flexible with cable end || power circuit: screw connection 2 2.5-10 mm² - cable stiffness: flexible with cable end || power circuit: screw connection 1 2.5-25 mm² - cable stiffness: solid without cable end || power circuit: screw connection 2 2.5-16 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
Coil Technology without built-in suppressor module
Minimum Switching Voltage 17 V for signalling circuit
Maximum Operating Rate 3600 cyc/h 60 °C
Signalling Circuit Frequency 25...400 Hz
Tightening Torque power circuit 7 N.m screw connectors 16-25 mm² hexagonal 4 mm || power circuit 5 N.m screw connectors 2.5-16 mm² hexagonal 4 mm || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2
Electrical Durability 0.6 Mcycles 60 A AC-1 <= 440 V || 1 Mcycles 40 A AC-3 <= 440 V
Mechanical Durability 5 Mcycles
Inrush Power In W 19-19 W 20 °C)
Auxiliary Contacts Type mechanically linked 1 NO IEC 60947-5-1
Operating Time 4...19 ms opening || 12...26 ms closing
Width 55 mm
Depth 122 mm
[Icw] Rated Short-Time Withstand Current 520 A 40 °C - 10 s for power circuit || 900 A 40 °C - 1 s for power circuit || 110 A 40 °C - 10 min for power circuit || 260 A 40 °C - 1 min for power circuit || 100 A - 1 s for signalling circuit || 120 A - 500 ms for signalling circuit || 140 A - 100 ms for signalling circuit
Heat Dissipation 4-5 W 50/60 Hz
[Uc] Control Circuit Voltage 24 V DC
Auxiliary Contact Composition 1 NO
Contactor Application motor control || resistive load
Product Or Component Type contactor
Product Name Easy TeSys DPE
Range Easy TeSys
Pole Contact Composition 3 NO
Utilisation Category AC-1 || AC-3
[Ie] Rated Operational Current 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit || 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
Poles Description 3P
Maximum Horse Power Rating 3 hp at 115 V AC 50/60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 15 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 15 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 40 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 40 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Motor Power Kw 18.5 kW 220...230 V AC 50/60 Hz || 30 kW 380...400 V AC 50/60 Hz || 37 kW 500 V AC 50/60 Hz || 37 kW 660...690 V AC 50/60 Hz
Device Short Name DPE
Read more arrow Read less arrow
*New items come with up to 24 month Obso Warranty
Our previously used items and repair options come with 12 months Obso Warranty.


"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
*Same & Next Day Delivery & Collection is available for stock from our UK and NL branches. Next-day delivery collection and 2 day delivery is available for stock sourced from our partners. In 90% of cases, we can deliver faster than the manufacturer’s ETA where required.

Standard options for delivery are also available where required.


"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
We are ISO 9001 accredited so you have peace of mind with your purchase.

What our customers say about us

Trustpilot

1

Step 1

    Part added for enquiry

    2

    Step 2

    Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.

    3

    Step 3

    We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.

    4

    Step 4

    Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.