BMXART0414

analog isolated low level input module, Modicon X80, 4 inputs, 40mV positive or negative

AVAILABLE

GET A QUOTE NOW

This analog input module is part of the Modicon X80 modules. It has 4 isolated low level inputs (15 bits + sign). It offers, voltage, thermocouple, temperature probe or resistor inputs depending on configuration choice. It occupies a single slot on the rack and it has a case which provides IP 20 protection of the electronics.
Read more arrow Read less arrow
Specification Value
Mtbf Reliability 1400000 H
Measurement Error +/- 0.7 °C Ni 1000 25 °C || +/- 1.3 °C Ni 1000 0...60 °C || +/- 2 °C Pt 100 0...60 °C || +/- 2 °C Pt 1000 0...60 °C || +/- 2.1 °C Ni 100 25 °C || +/- 2.1 °C Pt 100 25 °C || +/- 2.1 °C Pt 1000 25 °C || +/- 2.7 °C thermocouple U 25 °C || +/- 2.8 °C thermocouple J 25 °C || +/- 3 °C Ni 100 0...60 °C || +/- 3 °C thermocouple L 25 °C || +/- 3.2 °C thermocouple R 25 °C || +/- 3.2 °C thermocouple S 25 °C || +/- 3.5 °C thermocouple B 25 °C || +/- 3.7 °C thermocouple E 25 °C || +/- 3.7 °C thermocouple K 25 °C || +/- 3.7 °C thermocouple N 25 °C || +/- 3.7 °C thermocouple T 25 °C || +/- 4 °C Cu 10 0...60 °C || +/- 4 °C Cu 10 25 °C || +/- 4.5 °C thermocouple J 0...60 °C || +/- 4.5 °C thermocouple L 0...60 °C || +/- 4.5 °C thermocouple R 0...60 °C || +/- 4.5 °C thermocouple S 0...60 °C || +/- 4.5 °C thermocouple U 0...60 °C || +/- 5 °C thermocouple B 0...60 °C || +/- 5 °C thermocouple E 0...60 °C || +/- 5 °C thermocouple K 0...60 °C || +/- 5 °C thermocouple N 0...60 °C || +/- 5 °C thermocouple T 0...60 °C || <= 0.15 % of full scale +/- 1.28 V 0...60 °C || <= 0.15 % of full scale +/- 160 mV 0...60 °C || <= 0.15 % of full scale +/- 320 mV 0...60 °C || <= 0.15 % of full scale +/- 40 mV 0...60 °C || <= 0.15 % of full scale +/- 640 mV 0...60 °C || <= 0.15 % of full scale +/- 80 mV 0...60 °C || <= 0.2 % of full scale 400 Ohm 0...60 °C || <= 0.2 % of full scale 4000 Ohm 0...60 °C || 0.05 % of full scale +/- 1.28 V 25 °C || 0.05 % of full scale +/- 160 mV 25 °C || 0.05 % of full scale +/- 320 mV 25 °C || 0.05 % of full scale +/- 40 mV 25 °C || 0.05 % of full scale +/- 640 mV 25 °C || 0.05 % of full scale +/- 80 mV 25 °C || 0.12 % of full scale 400 Ohm 25 °C || 0.12 % of full scale 4000 Ohm 25 °C
Maximum Conversion Value +/- 100 % 400 Ohm || +/- 100 % 4000 Ohm || +/- 102.5 % +/- 1.28 V || +/- 102.5 % +/- 160 mV || +/- 102.5 % +/- 320 mV || +/- 102.5 % +/- 40 mV || +/- 102.5 % +/- 640 mV || +/- 102.5 % +/- 80 mV
Type Of Filter first order digital filtering
Status Led 1 LED (Green) RUN || 1 LED per channel (Green) channel diagnostic || 1 LED (Red) ERR || 1 LED (Red) I/O
Temperature Drift 25 ppm/°C 400 Ohm || 25 ppm/°C 4000 Ohm || 25 ppm/°C Ni 1000 || 25 ppm/°C thermocouple B || 25 ppm/°C thermocouple E || 25 ppm/°C thermocouple J || 25 ppm/°C thermocouple K || 25 ppm/°C thermocouple L || 25 ppm/°C thermocouple N || 25 ppm/°C thermocouple R || 25 ppm/°C thermocouple S || 25 ppm/°C thermocouple T || 25 ppm/°C thermocouple U || 30 ppm/°C +/- 1.28 V || 30 ppm/°C +/- 160 mV || 30 ppm/°C +/- 320 mV || 30 ppm/°C +/- 40 mV || 30 ppm/°C +/- 640 mV || 30 ppm/°C +/- 80 mV || 30 ppm/°C Cu 10 || 30 ppm/°C Ni 100 || 30 ppm/°C Pt 100 || 30 ppm/°C Pt 1000
Recalibration internal
Cold Junction Compensation external by Pt100 probe
Current Consumption 150 mA 3.3 V DC || 40 mA 24 V DC
Analogue Input Resolution 15 bits + sign
Net Weight 0.135 kg
Isolation Voltage 1400 V DC between channels and bus || 750 V DC between channels || 750 V DC between channels and ground
Differential Mode Rejection 60 dB 50/60 Hz
Nominal Read Cycle Time 400 ms with temperature probe || 200 ms with thermocouple
Detection Type open circuit Cu 10 || open circuit Ni 100 || open circuit Ni 1000 || open circuit Pt 100 || open circuit Pt 1000 || open circuit thermocouple B || open circuit thermocouple E || open circuit thermocouple J || open circuit thermocouple K || open circuit thermocouple L || open circuit thermocouple N || open circuit thermocouple R || open circuit thermocouple S || open circuit thermocouple T || open circuit thermocouple U
Maximum Wiring Resistance 20 Ohm 2 wires Cu 10 || 20 Ohm 2 wires Ni 100 || 20 Ohm 2 wires Pt 100 || 20 Ohm 3 wires Cu 10 || 20 Ohm 3 wires Ni 100 || 20 Ohm 3 wires Pt 100 || 200 Ohm 2 wires Ni 1000 || 200 Ohm 2 wires Pt 1000 || 200 Ohm 3 wires Ni 1000 || 200 Ohm 3 wires Pt 1000 || 50 Ohm 4 wires Cu 10 || 50 Ohm 4 wires Ni 100 || 50 Ohm 4 wires Pt 100 || 500 Ohm 4 wires Ni 1000 || 500 Ohm 4 wires Pt 1000
Operating Altitude 0...6561.68 ft (0...2000 m) || 2000...5000 m with derating factor
Common Mode Rejection 120 dB 50/60 Hz
Analog/Digital Conversion sigma delta 16 bits
Measurement Resolution 0.1 °C Cu 10 || 0.1 °C Ni 100 || 0.1 °C Ni 1000 || 0.1 °C Pt 100 || 0.1 °C Pt 1000 || 0.1 °C thermocouple B || 0.1 °C thermocouple E || 0.1 °C thermocouple J || 0.1 °C thermocouple K || 0.1 °C thermocouple L || 0.1 °C thermocouple N || 0.1 °C thermocouple R || 0.1 °C thermocouple S || 0.1 °C thermocouple T || 0.1 °C thermocouple U || 1280/2exp14 mV +/- 1.28 V || 160/2exp14 mV +/- 160 mV || 320/2exp14 mV +/- 320 mV || 40/2exp14 mV +/- 40 mV || 12.5 mOhm 400 Ohm || 125 mOhm 4000 Ohm || 640/2exp14 mV +/- 640 mV || 80/2exp14 mV +/- 80 mV
Permitted Overload On Inputs +/- 7.5 V +/- 1.28 V || +/- 7.5 V +/- 160 mV || +/- 7.5 V +/- 320 mV || +/- 7.5 V +/- 40 mV || +/- 7.5 V +/- 640 mV || +/- 7.5 V +/- 80 mV
Range Of Product Modicon X80
Product Or Component Type analog input module
Input Level low level
Electrical Connection 40 ways 1 connector
Input Output Isolation isolated
Analogue Input Number 4
Analogue Input Type voltage +/- 1.28 V || voltage +/- 160 mV || voltage +/- 320 mV || voltage +/- 40 mV || voltage +/- 640 mV || voltage +/- 80 mV || resistor 400 Ohm 2 wires || resistor 400 Ohm 3 wires || resistor 400 Ohm 4 wires || resistor 4000 Ohm 2 wires || resistor 4000 Ohm 3 wires || resistor 4000 Ohm 4 wires || temperature probe -100...+260 °C Cu 10 || temperature probe -100...+450 °C Pt 100 UL/JIS || temperature probe -100...+450 °C Pt 1000 UL/JIS || temperature probe -200...+850 °C Pt 100 IEC || temperature probe -200...+850 °C Pt 1000 IEC || temperature probe -60...+180 °C Ni 100 || temperature probe -60...+180 °C Ni 1000 || thermocouple +130...+1820 °C thermocouple B || thermocouple +270...+1300 °C thermocouple N || thermocouple -200...+600 °C thermocouple U || thermocouple -200...+760 °C thermocouple J || thermocouple -200...+900 °C thermocouple L || thermocouple -270...+1000 °C thermocouple E || thermocouple -270...+1370 °C thermocouple K || thermocouple -270...+400 °C thermocouple T || thermocouple -50...+1769 °C thermocouple R || thermocouple -50...+1769 °C thermocouple S
Read more arrow Read less arrow
*New items come with up to 24 month Obso Warranty
Our previously used items and repair options come with 12 months Obso Warranty.


"Super service! Everything was processed very quickly and competently and the personal support was excellent. I would always choose Obso Automation again! Many thanks for the great support." - MJ
*Same & Next Day Delivery & Collection is available for stock from our UK and NL branches. Next-day delivery collection and 2 day delivery is available for stock sourced from our partners. In 90% of cases, we can deliver faster than the manufacturer’s ETA where required.

Standard options for delivery are also available where required.


"Professional, courteous and accurate. Obsolete part quoted same day and supplied next" - PT
We are ISO 9001 accredited so you have peace of mind with your purchase.

What our customers say about us

Trustpilot

1

Step 1

    Part added for enquiry

    2

    Step 2

    Your personal Account Manager is already on it, delivering rapid responses and unbeatable service.

    3

    Step 3

    We don’t just process orders—we guarantee smooth delivery, full transparency, and zero headaches.

    4

    Step 4

    Our 10,000+ customers trust us for a reason. Get your quote now and experience automation without risk, delays, or uncertainty.